A Study on Partial Discharge signals and Noises at On-line Generator Stator Windings

被引:0
|
作者
Hee-Sang, Shin [1 ]
Jae-Chul, Kim [1 ]
机构
[1] Soong Sil Univ, Dept Elect Engn, Seoul, South Korea
来源
T& D ASIA: 2009 TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: ASIA AND PACIFIC | 2009年
关键词
diagnosis; high voltage generator; partial-discharge; stator winding;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Recently, the importance of supplying the reliable electric power is increasing. Insulation deterioration of stator winding is a major cause of faults in high voltage generators. Online partial discharge detection is useful technique to diagnose high voltage generators. Capacitive couplers have been the most widely used for on-line partial discharge detection in high voltage generators. However, interpretation of its result in time domain is very complex because of the mixed results with PD(Partial Discharges) and noises. In this paper, the partial discharge signals and noises were detected using 13[kV] class capacitive couplers at generator stator windings of hydro generators. Characteristics of the partial discharge signals and noises were analyzed. In addition, this paper presents system noise signals caused by sparks from slip rings, power tool operations, transformers and switchgears.
引用
收藏
页码:744 / 747
页数:4
相关论文
共 50 条
  • [1] RECENT DEVELOPMENTS IN IEEE AND IEC STANDARDS FOR OFF-LINE AND ON-LINE PARTIAL DISCHARGE TESTING OF MOTOR AND GENERATOR STATOR WINDINGS
    Stone, G. C.
    Stranges, Meredith K. W.
    Dunn, Donald G.
    2014 IEEE PETROLEUM AND CHEMICAL INDUSTRY TECHNICAL CONFERENCE (PCIC), 2014,
  • [2] Analysis of Off-Line and On-Line Partial Discharge in High Voltage Motor Stator Windings
    Kim, Hee-Dong
    Kong, Tae-Sik
    Lee, Sang-Kil
    Kim, Beom-Soo
    Kim, Doo-Young
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2015, 10 (03) : 1086 - 1092
  • [3] Novel on-line partial discharge monitoring system for generator/motor stator insulations
    Kim, YJ
    Hwang, DH
    Park, DY
    Song, SO
    ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, 2001, : 330 - 334
  • [4] Analysis of partial discharge pulse propagation along generator stator windings
    Su, Q
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 269 - 272
  • [5] Characteristics of On-line and Off-line Partial Discharge for Hydrogenerator Stator Windings with AE sensor and CT sensor
    Maeda, I.
    Kaneko, T.
    Takenouchi, O.
    Miyake, T.
    Sakoda, T.
    Otsubo, M.
    Fukumoto, S.
    Tokumitsu, A.
    Kai, T.
    Ando, M.
    ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 172 - 172
  • [6] Propagation mode and speed of partial discharge pulse through the stator windings of turbine generator
    Jiang, JG
    Liu, DH
    Deng, H
    Cao, HX
    Zhao, ZM
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 192 - 196
  • [7] Tracking Stator Bar Condition by On-line Partial Discharge Measurements
    McDermid, W.
    Black, T.
    2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 323 - 326
  • [8] Surface partial discharge in hydrogenerator stator windings: Causes, symptoms, and remedies
    Dehlinger, Nicolas
    Stone, Greg
    IEEE ELECTRICAL INSULATION MAGAZINE, 2020, 36 (03) : 7 - 18
  • [9] Identification of stator insulation deterioration using on-line partial discharge testing
    Zhu, H
    Green, V
    Sasic, M
    IEEE ELECTRICAL INSULATION MAGAZINE, 2001, 17 (06) : 21 - 26
  • [10] Experimental Study of Partial Discharge Pulses Propagation in Stator Winding of Hydro Generator
    Luo, Yuanlin
    Li, Zhaohui
    Chen, Tian
    PROCEEDINGS OF 2017 IEEE 2ND INFORMATION TECHNOLOGY, NETWORKING, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (ITNEC), 2017, : 773 - 777