The 1 year outcome of the transobturator retroluminal repositioning sling in the treatment of male stress urinary incontinence

被引:74
作者
Rehder, Peter [1 ]
Mitterberger, Michael J. [1 ]
Pichler, Renate [1 ]
Kerschbaumer, Andrea [1 ]
Glodny, Bernhard [2 ]
机构
[1] Med Univ Innsbruck, Dept Urol, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Dept Radiol, A-6020 Innsbruck, Austria
关键词
prostatectomy; urinary incontinence; suburethral sling; urodynamics; reconstructive surgery; quality of life; PROSTATECTOMY; MANAGEMENT; MEN;
D O I
10.1111/j.1464-410X.2010.09400.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE To evaluate the efficacy and safety of a transobturator retroluminal repositioning sling suspension in the treatment of male stress urinary incontinence (SUI) after prostate surgery. PATIENTS AND METHODS In 118 men with SUI after prostatic surgery, a transobturator retroluminal repositioning sling suspension was implanted. Patients were evaluated including: complete history and physical examination, 24-h pad test, a questionnaire (International Consultation on Incontinence Questionnaire, Short-Form), urodynamic evaluation and endoscopy. The surgical technique was described previously. The findings before and at 1 year after sling placement were compared. RESULTS At the 12-month follow-up, 73.7% of the men were cured, 16.9% were improved, and 9.3% were still incontinent. After sling placement the daily pad use decreased significantly (P < 0.001), while the ICIQ-SF improved significantly (P < 0.01). The detrusor voiding pressure, postvoid residual urine volume and maximal flow rates remained unchanged, while the Valsalva leak-point pressure improved significantly (P < 0.01). In 19.5% of the men, there was transient scrotal pain or perineal discomfort. In 5.1% of the men, postoperative urinary retention occurred but resolved spontaneously after a few weeks of catheter placement. In 1.7% of the men adductor pain was reported, which resolved spontaneously. There were no major complications. CONCLUSION The transobturator retroluminal repositioning sling suspension for the treatment of male SUI is effective and safe with a low complication rate after 1 year of follow-up.
引用
收藏
页码:1668 / 1671
页数:4
相关论文
共 50 条
[21]   Autologous Transobturator Urethral Sling Placement for Female Stress Urinary Incontinence [J].
Linder, Brian J. ;
Elliott, Daniel S. .
JOURNAL OF UROLOGY, 2015, 193 (03) :991-996
[23]   Prospective Evaluation of the Functional Sling Suspension for Male Postprostatectomy Stress Urinary Incontinence: Results after 1 Year [J].
Bauer, Ricarda M. ;
Mayer, Margit E. ;
Gratzke, Christian ;
Soljanik, Irina ;
Buchner, Alexander ;
Bastian, Patrick J. ;
Stief, Christian G. ;
Gozzi, Christian .
EUROPEAN UROLOGY, 2009, 56 (06) :928-933
[24]   Outcome of transobturator sling for treatment of female stress urinary incontinence applied as a single procedure or concomitantly with pelvic organ prolapse surgery [J].
Banas, Joanna ;
Jankiewicz, Katarzyna ;
Rechberger, Tomasz ;
Kolodynska, Aleksandra ;
Bogusiewicz, Michal .
ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2023, 30 (01) :190-194
[25]   Initial Experience and Results With a New Adjustable Transobturator Male System for the Treatment of Stress Urinary Incontinence [J].
Seweryn, Juergen ;
Bauer, Wilhelm ;
Ponholzer, Anton ;
Schramek, Paul .
JOURNAL OF UROLOGY, 2012, 187 (03) :956-961
[26]   Multicenter study of Advance® suburethral sling for treatment of postoperative urinary incontinence of male [J].
Mascle, L. ;
Descazeaud, A. ;
Robert, G. ;
Bernhard, J. -C. ;
Bensadoun, H. ;
Ferriere, J. -M. ;
Ballanger, P. ;
Pasticier, G. .
PROGRES EN UROLOGIE, 2015, 25 (05) :249-255
[27]   Adjustable retropubic suburethral sling Remeex® in the treatment of male stress urinary incontinence: One-year results [J].
Leizour, B. ;
Chevrot, A. ;
Wagner, L. ;
Droupy, S. ;
Costa, P. .
PROGRES EN UROLOGIE, 2017, 27 (04) :238-243
[28]   AdVance male sling in irradiated patients with stress urinary incontinence [J].
Zuckerman, Jack M. ;
Tisdale, Britton ;
McCammon, Kurt .
CANADIAN JOURNAL OF UROLOGY, 2011, 18 (06) :6013-6017
[29]   The male sling for stress urinary incontinence: Urodynamic and subjective assessment [J].
Ullrich, NFE ;
Comiter, CV .
JOURNAL OF UROLOGY, 2004, 172 (01) :204-206
[30]   Efficacy and safety of polypropylene single-mesh transobturator sling (TOT) in the treatment of female stress urinary incontinence [J].
Briozzo, Leonel ;
Nozar, Maria Fernanda ;
Fiol, Veronica ;
Curbelo, Fernando .
REVISTA MEDICA DEL URUGUAY, 2009, 25 (03) :141-148