Effect of using different metal and ceramic materials as restorations on stress distribution around dental implants: a comparative finite element study

被引:5
作者
Toussi, Cyrus Ahmadi [1 ]
Ezatpour, Hamid Reza [2 ]
Haddadnia, Javad [1 ]
Shiri, Jaber Gholami [2 ]
机构
[1] Hak Sabzevari Univ, Dept Med Engn, Sabzevar, Iran
[2] Sabzevar Univ New Technol, Fac Engn, Sabzevar, Iran
关键词
implant prosthesis; surrounding bone; finite element analysis; stress analysis; FIXED-PROSTHESIS; ZIRCONIA; SURVIVAL; ABUTMENTS; TITANIUM; RATES;
D O I
10.1088/2053-1591/aadc55
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The full ceramic dental prosthesis has recently been used as a common treatment alternative to metal ceramic ones mostly due to the esthetic aspects. However, it is unclear whether dental prosthesis with ceramic materials can be safely applied in restorations. To clarify the issue, six three-dimensional finite element models of four-unit implant supported prosthesis with different materials including InCeram Zirconia (ICZ) and In-Ceram Alumina (ICA) were designed using ABAQUS code version 6.5. Then, the typical load of 100Nwas applied to each model at different angles and the trends of maximum stress were explored at different components. The results show that using different full ceramic restorations are safe against usual occlusal loads. However, ICZ and ICA induce higher value of Von Mises stress which can be recommended in the anterior regions with low functional loads. Accordingly, the improved full ceramic dental prostheses can be used as an alternative clinical treatment to the metal ceramic.
引用
收藏
页数:12
相关论文
共 43 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]  
Adib MG, 2008, DENT J, V24, P131
[3]  
Agamy, 2016, EGYPT J HOSP MED, V63, P172, DOI [10.12816/0023843, DOI 10.12816/0023843]
[4]   Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue [J].
Bayraktar, HH ;
Morgan, EF ;
Niebur, GL ;
Morris, GE ;
Wong, EK ;
Keaveny, TM .
JOURNAL OF BIOMECHANICS, 2004, 37 (01) :27-35
[5]   Stress dissipation in the bone through various crown materials of dental implant restoration: a 2-D finite element analysis [J].
Bijjargi, Supriya ;
Chowdhary, Ramesh .
JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2013, 4 (03) :172-177
[6]   Evaluation of the Success Criteria for Zirconia Dental Implants: A Four-Year Clinical and Radiological Study [J].
Borgonovo, Andrea Enrico ;
Censi, Rachele ;
Vavassori, Virna ;
Dolci, Marcello ;
Luis Calvo-Guirado, Jose ;
Delgado Ruiz, Rafael Arcesio ;
Maiorana, Carlo .
INTERNATIONAL JOURNAL OF DENTISTRY, 2013, 2013
[7]   Finite element analysis of stress at implant-bone interface of dental implants with different structures [J].
Chen Liang-jian ;
He Hao ;
Li Yi-min ;
Li Ting ;
Guo Xiao-ping ;
Wang Rui-fang .
TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2011, 21 (07) :1602-1610
[8]   A clinical comparison of zirconia, metal and alumina fixed-prosthesis frameworks veneered with layered or pressed ceramic A three-year report [J].
Christensen, Rella P. ;
Ploeger, Brad J. .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (11) :1317-1329
[9]  
Conejo J., 2017, CURRENT ORAL HLTH RE, V4, P112, DOI [10.1007/s40496-017-0132-4, DOI 10.1007/S40496-017-0132-4]
[10]   Analysis of the effect of load direction on the stress distribution in dental implant [J].
Djebbar, N. ;
Serier, B. ;
Bouiadjra, B. Bachir ;
Benbarek, S. ;
Drai, A. .
MATERIALS & DESIGN, 2010, 31 (04) :2097-2101