Amperometric glucose biosensors based on Prussian Blue- and polyaniline-glucose oxidase modified electrodes

被引:158
|
作者
Garjonyte, R [1 ]
Malinauskas, A [1 ]
机构
[1] Inst Chem, LT-2600 Vilnius, Lithuania
关键词
biosensor; glucose oxidase; polyaniline; Prussian Blue;
D O I
10.1016/S0956-5663(00)00101-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The properties of glucose sensors fabricated by immobilization of glucose oxidase in a layer of electrochemically deposited polyaniline were investigated. Selective amperometric glucose sensors were prepared by immobilization of glucose oxidase on a Prussian Blue-modified platinum electrode in a layer of polyaniline during a one-step electropolymerization procedure from phosphate buffer. The influence of ascorbic acid and acetaminophen was completely eliminated due to impermeability of polyaniline to these substances. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:445 / 451
页数:7
相关论文
共 50 条
  • [41] An amperometric cholesterol biosensor based on cholesterol oxidase immobilized in polypyrrole on a Prussian blue modified electrode
    Li, JP
    Peng, TZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (06) : 669 - 673
  • [42] An Amperometric Glucose Biosensor Based on the Immobilization of Glucose Oxidase on the CuGeO3 Nanowire Modified Electrode
    Dong, Yong Ping
    Huang, Li
    Chu, Xiang Feng
    Pei, Li Zhai
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (06) : 571 - 576
  • [43] Synthesis of magnetic nanoparticles composed by Prussian blue and glucose oxidase for preparing highly sensitive and selective glucose biosensor
    Li, Jianping
    Wei, Xiaoping
    Yuan, Yonghai
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 139 (02) : 400 - 406
  • [44] Single-step procedure for the modification of graphite electrode by composite layer based on polypyrrole, Prussian blue and glucose oxidase
    Ramanavicius, Arunas
    Rekertaite, Asta Inese
    Valiunas, Raimondas
    Valiuniene, Aura
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 220 - 223
  • [45] Fast Fourier transformation electrochemical impedance spectroscopy for the investigation of inactivation of glucose biosensor based on graphite electrode modified by Prussian blue, polypyrrole and glucose oxidase
    Valiuniene, Ausra
    Rekertaite, Asta Inese
    Ramanaviciene, Almira
    Mikoliunaite, Lina
    Ramanavicius, Arunas
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2017, 532 : 165 - 171
  • [46] Optimisation of Glucose Biosensors Based on Sol–Gel Entrapment and Prussian Blue-Modified Screen-Printed Electrodes for Real Food Analysis
    Donatella Albanese
    Adriana Sannini
    Francesca Malvano
    Roberto Pilloton
    Marisa Di Matteo
    Food Analytical Methods, 2014, 7 : 1002 - 1008
  • [47] Physicochemical Characteristics of Polypyrrole/(Glucose oxidase)/(Prussian Blue)-based Biosensor Modified with Ni- and Co-Hexacyanoferrates
    Rekertaite, Asta Inese
    Valiuniene, Ausra
    Virbickas, Povilas
    Ramanavicius, Arunas
    ELECTROANALYSIS, 2019, 31 (01) : 50 - 57
  • [48] An Amperometric Biosensor for Glucose Determination Prepared from Glucose Oxidase Immobilized in Polyaniline-Polyvinylsulfonate Film
    Arslan, Fatma
    Ustabas, Selvin
    Arslan, Halit
    SENSORS, 2011, 11 (08) : 8152 - 8163
  • [49] Thermally stable improved first-generation glucose biosensors based on Nafion/glucose-oxidase modified heated electrodes
    Tseng, Ta-Feng
    Yang, Yang-Li
    Chuang, Min-Chieh
    Lou, Shyh-Liang
    Galik, Michal
    Flechsig, Gerd-Uwe
    Wang, Joseph
    ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (09) : 1819 - 1822
  • [50] Glucose oxidase electrodes via reconstitution of the apo-enzyme:: tailoring of novel glucose biosensors
    Katz, E
    Riklin, A
    Heleg-Shabtai, V
    Willner, I
    Bückmann, AF
    ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) : 45 - 58