Amperometric glucose biosensors based on Prussian Blue- and polyaniline-glucose oxidase modified electrodes

被引:158
|
作者
Garjonyte, R [1 ]
Malinauskas, A [1 ]
机构
[1] Inst Chem, LT-2600 Vilnius, Lithuania
关键词
biosensor; glucose oxidase; polyaniline; Prussian Blue;
D O I
10.1016/S0956-5663(00)00101-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The properties of glucose sensors fabricated by immobilization of glucose oxidase in a layer of electrochemically deposited polyaniline were investigated. Selective amperometric glucose sensors were prepared by immobilization of glucose oxidase on a Prussian Blue-modified platinum electrode in a layer of polyaniline during a one-step electropolymerization procedure from phosphate buffer. The influence of ascorbic acid and acetaminophen was completely eliminated due to impermeability of polyaniline to these substances. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:445 / 451
页数:7
相关论文
共 50 条
  • [21] Amperometric glucose microbiosensor based on a Prussian Blue modified carbon fiber electrode for physiological applications
    Salazar, P.
    O'Neill, R. D.
    Martin, M.
    Roche, R.
    Gonzalez-Mora, J. L.
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 152 (02) : 137 - 143
  • [22] Glucose Sensor Based on Glucose Oxidase-Lipid LB Film Immobilized in Prussian Blue Layer
    Lee, Dong-Yun
    Kafi, A. K. M.
    Choi, Won-Suk
    Park, Sang-Hyun
    Kwon, Young-Soo
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2008, 8 (09) : 4543 - 4547
  • [23] Novel Glucose Oxidase Interlocked Prussian Blue/Polysulfone Stereo-Structure and its Application in Amperometric Glucose Biosensor
    Wang, Cang
    Pan, Min
    Chen, Hang
    Chen, Dajing
    Chen, Yuquan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (08): : 8014 - 8027
  • [24] Electrochemical determination of glucose using polyaniline electrode modified by glucose oxidase
    Gvozdenovic, M. M.
    Jugovic, B. Z.
    Bezbradica, D. I.
    Antov, M. G.
    Knezevic-Jugovic, Z. D.
    Grgur, B. N.
    FOOD CHEMISTRY, 2011, 124 (01) : 396 - 400
  • [25] A biosensor based on the glucose oxidase film modified by titanic sol-gel doping with Prussian blue nanoparticles
    Yang, ZY
    Li, JP
    Fang, C
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (04) : 538 - 542
  • [26] Glucose biosensor based on glucose oxidase immobilized in electropolymerized polypyrrole and poly(o-phenylenediamine) films on a Prussian Blue-modified electrode
    Garjonyte, R
    Malinauskas, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (1-2) : 122 - 128
  • [27] Microbiosensors for glucose based on Prussian Blue modified carbon fiber electrodes for in vivo monitoring in the central nervous system
    Salazar, P.
    Martin, M.
    Roche, R.
    Gonzalez-Mora, J. L.
    O'Neill, R. D.
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) : 748 - 753
  • [28] Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system
    Teng YuanJie
    Chen Chen
    Zhou ChangXiang
    Zhao HongLi
    Lan MinBo
    SCIENCE CHINA-CHEMISTRY, 2010, 53 (12) : 2581 - 2586
  • [29] Galactose Oxidase/Prussian Blue Based Biosensors
    Charmantray, Franck
    Touisni, Nadia
    Hecquet, Laurence
    Noguer, Thierry
    Mousty, Christine
    ELECTROANALYSIS, 2015, 27 (06) : 1341 - 1344
  • [30] An amperometric glucose biosensor based on poly(o-aminophenol) and Prussian blue films at platinum electrode
    Pan, DW
    Chen, JH
    Nie, LH
    Tao, WY
    Yao, SZ
    ANALYTICAL BIOCHEMISTRY, 2004, 324 (01) : 115 - 122