Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging

被引:67
|
作者
Kim, YK
Lee, JM [1 ]
Kim, CS
Chung, GH
Kim, CY
Kim, IH
机构
[1] Chonbuk Natl Univ Hosp & Med Sch, Dept Diagnost Radiol, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul, South Korea
[4] Chonbuk Natl Univ Hosp & Med Sch, Dept Gen Surg, Seoul, South Korea
[5] Chonbuk Natl Univ Hosp & Med Sch, Dept Internal Med, Seoul, South Korea
关键词
liver; neoplasm; magnetic resonance imaging; contrast agents;
D O I
10.1007/s00330-004-2570-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare the diagnostic performance of gadobenate dimeglumine (GdBOPTA)-enhanced MR imaging, including dynamic phases and one-hour delayed phase, versus superparamagnetic iron oxide (SPIO)-enhanced imaging for detection of liver metastases. Twenty-three patients with 59 liver metastases underwent Gd-BOPTA-enhanced MR imaging (unenhanced, arterial, portal, equilibrium and one-hour delayed phase) using three-dimensional volumetric interpolated imaging and SPIO-enhanced T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences on a 1.5-T unit. Three observers independently interpreted the three sets of images, i.e. Gd-BOPTA-enhanced dynamic MRI (set 1), delayed phase imaging (set 2) and SPIO-enhanced MRI (set 3). Diagnostic accuracy was evaluated using the alternative-free response receiver operating chracteristic (ROC) analysis. Sensitivity and positive predictive value were also evaluated. The mean accuracy (Az values) and sensitivity of Gd-BOPTA-enhanced delayed phase imaging (0.982, 95.5%) were comparable to those of SPIO-enhanced imaging (0.984, 97.2%). In addition, Az values and sensitivities of both imaging sets were significantly higher than those of Gd-BOPTA-enhanced dynamic images (0.826, 77.4%: p<0.05). There was no significant difference in the positive predictive value among the three image sets. Gd-BOPTA-enhanced delayed phase imaging showed comparable diagnostic performance to SPIO-enhanced imaging for the detection of liver metastases, and had a better diagnostic performance than Gd-BOPTA-enhanced dynamic images.
引用
收藏
页码:220 / 228
页数:9
相关论文
共 46 条
  • [41] Whole-body three-dimensional contrast-enhanced magnetic resonance (MR) angiography with parallel imaging techniques on a multichannel MR system for the detection of various systemic arterial diseases
    Lin, Jiang
    Chen, Bin
    Wang, Jian-Hua
    Zeng, Meng-Su
    Wang, Yi-Xiang
    HEART AND VESSELS, 2006, 21 (06) : 395 - 398
  • [42] Whole-body three-dimensional contrast-enhanced magnetic resonance (MR) angiography with parallel imaging techniques on a multichannel MR system for the detection of various systemic arterial diseases
    Jiang Lin
    Bin Chen
    Jian-Hua Wang
    Meng-Su Zeng
    Yi-Xiang Wang
    Heart and Vessels, 2006, 21 : 395 - 398
  • [43] Portal vein and its tributaries: Evaluation with thin-section three-dimensional contrast-enhanced dynamic fat-suppressed MR imaging
    Ito, K
    Blasbalg, R
    Hussain, SM
    Mitchell, DG
    RADIOLOGY, 2000, 215 (02) : 381 - 386
  • [44] Detection of hepatic metastases using ferucarbotran-enhanced MR imaging: Feasibility and diagnostic accuracy of three-dimensional sensitivity-encoding water-excitation multishot echo-planar sequence (3D-SWEEP)
    Mori, Kensaku
    Takahashi, Nobuyuki
    Hiratsuka, Makiko
    Shiigai, Masanari
    Minami, Manabu
    Oda, Tatsuya
    Ohkohchi, Nobuhiro
    Morishita, Yukio
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (05) : 1110 - 1116
  • [45] Gd-EOB-DTPA-enhanced 3.0 T MR imaging: quantitative and qualitative comparison of hepatocyte-phase images obtained 10 min and 20 min after injection for the detection of liver metastases from colorectal carcinoma
    Keitaro Sofue
    Masakatsu Tsurusaki
    Hiroyuki Tokue
    Yasuaki Arai
    Kazuro Sugimura
    European Radiology, 2011, 21 : 2336 - 2343
  • [46] Gd-EOB-DTPA-enhanced 3.0 T MR imaging: quantitative and qualitative comparison of hepatocyte-phase images obtained 10 min and 20 min after injection for the detection of liver metastases from colorectal carcinoma
    Sofue, Keitaro
    Tsurusaki, Masakatsu
    Tokue, Hiroyuki
    Arai, Yasuaki
    Sugimura, Kazuro
    EUROPEAN RADIOLOGY, 2011, 21 (11) : 2336 - 2343