Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging

被引:67
|
作者
Kim, YK
Lee, JM [1 ]
Kim, CS
Chung, GH
Kim, CY
Kim, IH
机构
[1] Chonbuk Natl Univ Hosp & Med Sch, Dept Diagnost Radiol, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul, South Korea
[4] Chonbuk Natl Univ Hosp & Med Sch, Dept Gen Surg, Seoul, South Korea
[5] Chonbuk Natl Univ Hosp & Med Sch, Dept Internal Med, Seoul, South Korea
关键词
liver; neoplasm; magnetic resonance imaging; contrast agents;
D O I
10.1007/s00330-004-2570-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare the diagnostic performance of gadobenate dimeglumine (GdBOPTA)-enhanced MR imaging, including dynamic phases and one-hour delayed phase, versus superparamagnetic iron oxide (SPIO)-enhanced imaging for detection of liver metastases. Twenty-three patients with 59 liver metastases underwent Gd-BOPTA-enhanced MR imaging (unenhanced, arterial, portal, equilibrium and one-hour delayed phase) using three-dimensional volumetric interpolated imaging and SPIO-enhanced T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences on a 1.5-T unit. Three observers independently interpreted the three sets of images, i.e. Gd-BOPTA-enhanced dynamic MRI (set 1), delayed phase imaging (set 2) and SPIO-enhanced MRI (set 3). Diagnostic accuracy was evaluated using the alternative-free response receiver operating chracteristic (ROC) analysis. Sensitivity and positive predictive value were also evaluated. The mean accuracy (Az values) and sensitivity of Gd-BOPTA-enhanced delayed phase imaging (0.982, 95.5%) were comparable to those of SPIO-enhanced imaging (0.984, 97.2%). In addition, Az values and sensitivities of both imaging sets were significantly higher than those of Gd-BOPTA-enhanced dynamic images (0.826, 77.4%: p<0.05). There was no significant difference in the positive predictive value among the three image sets. Gd-BOPTA-enhanced delayed phase imaging showed comparable diagnostic performance to SPIO-enhanced imaging for the detection of liver metastases, and had a better diagnostic performance than Gd-BOPTA-enhanced dynamic images.
引用
收藏
页码:220 / 228
页数:9
相关论文
共 46 条
  • [31] Detection and characterization of focal liver lesions using superparamagnetic iron oxide-enhanced magnetic resonance imaging: comparison between ferumoxides-enhanced T1-weighted imaging and delayed-phase gadolinium-enhanced T1-weighted imaging
    Takahama, K
    Amano, Y
    Hayashi, H
    Ishihara, M
    Kumazaki, T
    ABDOMINAL IMAGING, 2003, 28 (04) : 525 - 530
  • [32] Development of hepatomas in hyperplastic nodules induced in the rat liver: Detection with superparamagnetic iron oxide-enhanced magnetic resonance imaging
    Yamamoto, H
    Yamashita, Y
    Takahashi, M
    ACADEMIC RADIOLOGY, 1996, 3 (04) : 330 - 335
  • [33] Arterial enhancing-only nodules less than 2 cm in diameter in patients with liver cirrhosis: Predictors of hepatocellular carcinoma diagnosis on gadobenate dimeglumine-enhanced mr imaging
    Quaia, Emilio
    Pizzolato, Riccardo
    De Paoli, Luca
    Angileri, Roberta
    Ukmar, Maja
    Cova, Maria Assunta
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (04) : 892 - 902
  • [34] Detection of hepatocellular carcinoma: comparison of ferumoxides-enhanced and gadolinium-enhanced dynamic three-dimensional volume interpolated breath-hold MR imaging
    Kwak, HS
    Lee, JM
    Kim, YK
    Lee, YH
    Kim, CS
    EUROPEAN RADIOLOGY, 2005, 15 (01) : 140 - 147
  • [35] Detection of hepatocellular carcinoma: comparison of ferumoxides-enhanced and gadolinium-enhanced dynamic three-dimensional volume interpolated breath-hold MR imaging
    Hyo-Sung Kwak
    Jeong-Min Lee
    Young-Kon Kim
    Young Hwan Lee
    Chong-Soo Kim
    European Radiology, 2005, 15 : 140 - 147
  • [36] CONTRAST-ENHANCED MR-IMAGING OF LIVER AND SPLEEN - 1ST EXPERIENCE IN HUMANS WITH A NEW SUPERPARAMAGNETIC IRON-OXIDE
    HAMM, B
    STAKS, T
    TAPUITZ, M
    MAIBAUER, R
    SPEIDEL, A
    HUPPERTZ, A
    FRENZEL, T
    LAWACZECK, R
    WOLF, KJ
    LANGE, L
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05): : 659 - 668
  • [37] Dynamic contrast-enhanced three-dimensional MR imaging of liver parenchyma: Source images and angiographic reconstructions to define hepatic arterial anatomy
    Lavelle, MT
    Lee, VS
    Rofsky, NM
    Krinsky, GA
    Weinreb, JC
    RADIOLOGY, 2001, 218 (02) : 389 - 394
  • [38] Preliminary experience with superparamagnetic iron oxide-enhanced dynamic magnetic resonance imaging and comparison with contrast-enhanced computed tomography in endoleak detection after endovascular aneurysm repair
    Ichihashi, Shigeo
    Marugami, Nagaaki
    Tanaka, Toshihiro
    Iwakoshi, Shinichi
    Kurumatani, Norio
    Kitano, Satoru
    Nogi, Akihiro
    Kichikawa, Kimihiko
    JOURNAL OF VASCULAR SURGERY, 2013, 58 (01) : 66 - 72
  • [39] Simultaneous Visualization of Vessels and Brain Tumor with Contrast-enhanced Three-dimensional Phase-contrast MR Imaging
    Shigenaga, Yutaka
    Sasaki, Masato
    Ishimoto, Takeshi
    Ama, Keiko
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2018, 17 (02) : 184 - 188
  • [40] Inferior phrenic arteries: Depiction with thin-section three-dimensional contrast-enhanced dynamic MR imaging with fat suppression
    Ito, K
    Kim, MJ
    Mitchell, DG
    Honjo, K
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (02) : 201 - 206