Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging

被引:67
|
作者
Kim, YK
Lee, JM [1 ]
Kim, CS
Chung, GH
Kim, CY
Kim, IH
机构
[1] Chonbuk Natl Univ Hosp & Med Sch, Dept Diagnost Radiol, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul, South Korea
[4] Chonbuk Natl Univ Hosp & Med Sch, Dept Gen Surg, Seoul, South Korea
[5] Chonbuk Natl Univ Hosp & Med Sch, Dept Internal Med, Seoul, South Korea
关键词
liver; neoplasm; magnetic resonance imaging; contrast agents;
D O I
10.1007/s00330-004-2570-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare the diagnostic performance of gadobenate dimeglumine (GdBOPTA)-enhanced MR imaging, including dynamic phases and one-hour delayed phase, versus superparamagnetic iron oxide (SPIO)-enhanced imaging for detection of liver metastases. Twenty-three patients with 59 liver metastases underwent Gd-BOPTA-enhanced MR imaging (unenhanced, arterial, portal, equilibrium and one-hour delayed phase) using three-dimensional volumetric interpolated imaging and SPIO-enhanced T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences on a 1.5-T unit. Three observers independently interpreted the three sets of images, i.e. Gd-BOPTA-enhanced dynamic MRI (set 1), delayed phase imaging (set 2) and SPIO-enhanced MRI (set 3). Diagnostic accuracy was evaluated using the alternative-free response receiver operating chracteristic (ROC) analysis. Sensitivity and positive predictive value were also evaluated. The mean accuracy (Az values) and sensitivity of Gd-BOPTA-enhanced delayed phase imaging (0.982, 95.5%) were comparable to those of SPIO-enhanced imaging (0.984, 97.2%). In addition, Az values and sensitivities of both imaging sets were significantly higher than those of Gd-BOPTA-enhanced dynamic images (0.826, 77.4%: p<0.05). There was no significant difference in the positive predictive value among the three image sets. Gd-BOPTA-enhanced delayed phase imaging showed comparable diagnostic performance to SPIO-enhanced imaging for the detection of liver metastases, and had a better diagnostic performance than Gd-BOPTA-enhanced dynamic images.
引用
收藏
页码:220 / 228
页数:9
相关论文
共 46 条
  • [21] Liver metastases from colorectal cancer: imaging with superparamagnetic iron oxide (SPIO)-enhanced MR imaging, computed tomography and positron emission tomography
    Rappeport, Eli D.
    Loft, Annika
    ABDOMINAL IMAGING, 2007, 32 (05): : 624 - 634
  • [22] HEPATOCELLULAR-CARCINOMA IN CIRRHOTIC LIVERS - DETECTION WITH UNENHANCED AND IRON OXIDE-ENHANCED MR-IMAGING
    YAMAMOTO, H
    YAMASHITA, Y
    YOSHIMATSU, S
    BABA, Y
    HATANAKA, Y
    MURAKAMI, R
    NISHIHARU, T
    TAKAHASHI, M
    HIGASHIDA, Y
    MORIBE, N
    RADIOLOGY, 1995, 195 (01) : 106 - 112
  • [23] Liver metastases from colorectal cancer: imaging with superparamagnetic iron oxide (SPIO)-enhanced MR imaging, computed tomography and positron emission tomography
    Eli D. Rappeport
    Annika Loft
    Abdominal Imaging, 2007, 32 : 624 - 634
  • [24] Detection of hepatic metastases by superparamagnetic iron oxide-enhanced MR imaging: prospective comparison between 1.5-T and 3.0-T images in the same patients
    Keitaro Sofue
    Masakatsu Tsurusaki
    Mototaka Miyake
    Aine Sakurada
    Yasuaki Arai
    Kazuro Sugimura
    European Radiology, 2010, 20 : 2265 - 2273
  • [25] Detection of hepatic metastases by superparamagnetic iron oxide-enhanced MR imaging: prospective comparison between 1.5-T and 3.0-T images in the same patients
    Sofue, Keitaro
    Tsurusaki, Masakatsu
    Miyake, Mototaka
    Sakurada, Aine
    Arai, Yasuaki
    Sugimura, Kazuro
    EUROPEAN RADIOLOGY, 2010, 20 (09) : 2265 - 2273
  • [26] Superparamagnetic iron oxide-enhanced MR imaging for focal hepatic lesions: a comparison with CT during arterioportography plus CT during hepatic arteriography
    Akihiro Tanimoto
    Go Wakabayashi
    Hiroshi Shinmoto
    Seishi Nakatsuka
    Shigeo Okuda
    Sachio Kuribayashi
    Journal of Gastroenterology, 2005, 40 : 371 - 380
  • [27] Added diagnostic value of T2-weighted MR imaging to gadolinium-enhanced three-dimensional dynamic MR imaging for the detection of small hepatocellular carcinomas
    Kim, Young Kon
    Lee, Young Hwan
    Kim, Chong Soo
    Han, Young Min
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 67 (02) : 304 - 310
  • [28] Hypervascular hepatocellular carcinoma in the cirrhotic liver: diffusion-weighted imaging versus superparamagnetic iron oxide-enhanced MRI
    Chung, Jin
    Yu, Jeong-Sik
    Kim, Dae Jung
    Chung, Jae-Joon
    Kim, Joo Hee
    Kim, Ki Whang
    MAGNETIC RESONANCE IMAGING, 2011, 29 (09) : 1235 - 1243
  • [29] Superparamagnetic iron oxide-enhanced MR imaging for focal hepatic lesions: a comparison with CT during arterioportography plus CT during hepatic arteriography
    Tanimoto, A
    Wakabayashi, G
    Shinmoto, H
    Nakatsuka, S
    Okuda, S
    Kuribayashi, S
    JOURNAL OF GASTROENTEROLOGY, 2005, 40 (04) : 371 - 380
  • [30] Non-invasive detection of liver fibrosis: Is superparamagnetic iron oxide particle-enhanced MR imaging a contributive technique?
    Lucidarme, O
    Baleston, F
    Cadi, M
    Bellin, MF
    Charlotte, F
    Ratziu, V
    Grenier, PA
    EUROPEAN RADIOLOGY, 2003, 13 (03) : 467 - 474