摘要
The increasing number of grid-connected non-linear loads causes more disruption problems to power grids. Indeed, these loads absorb periodic currents with different waveforms and consume reactive power which causes the emergence of harmonic distortion in the mains current and voltage levels that should be avoided. In order to solve this drawback, this paper presents a control scheme based on shunt active filter supplied by a wind turbine generator to compensate at the same time the harmonics currents and the reactive power caused by nonlinear loads. The aim of this compensation is to provide a high voltage quality at the point of common coupling (PCC) through a proper control of wind turbine distributed generators interface converters. The system is simulated using MATLAB software and results are provided in order to show the performance of this compensation technique in terms of harmonic distortion reduction and power-factor improvement.
引用
收藏
页数:5
相关论文
共 10 条
[1]  
[Anonymous], 1992, 5191992 IEEE
[2]   Control and Performance of a Cascaded Shunt Active Power Filter for Aircraft Electric Power System [J].
Chen, Zhong ;
Luo, Yingpeng ;
Chen, Miao .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (09) :3614-3623
[3]   High-Power-Factor Single-Phase Diode Rectifier Driven by Repetitively Controlled IPM Motor [J].
Inazuma, Kazuya ;
Utsugi, Hiroaki ;
Ohishi, Kiyoshi ;
Haga, Hitoshi .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (10) :4427-4437
[4]   Assessing the Collective Harmonic Impact of Modern Residential Loads-Part II: Applications [J].
Jiang, Chen ;
Salles, Diogo ;
Xu, Wilsun ;
Freitas, Walmir .
IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (04) :1947-1955
[5]   Real-time implementation of PI and fuzzy logic controllers based shunt active filter control strategies for power quality improvement [J].
Mikkili, Suresh ;
Panda, A. K. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 43 (01) :1114-1126
[6]   Managing the responsibility for harmonic distortion in power networks [J].
Pfajfar, T. ;
Blazic, B. ;
Papic, I. .
ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) :2538-2545
[7]   A Lyapunov-Function-Based Control for a Three-Phase Shunt Hybrid Active Filter [J].
Rahmani, Salem ;
Hamadi, Abdelhamid ;
Al-Haddad, Kamal .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (03) :1418-1429
[8]   A novel control strategy of a distributed generator operating in seven modes for ancillary services under grid faults [J].
Rekik, Mouna ;
Abdelkafi, Achraf ;
Krichen, Lotfi .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 47 :100-108
[9]  
TIMENS RB, 2011, EL COMP EMC IEEE INT, P393
[10]   Topologies and control strategies of multi-functional grid-connected inverters for power quality enhancement: A comprehensive review [J].
Zeng, Zheng ;
Yang, Huan ;
Zhao, Rongxiang ;
Cheng, Chong .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 24 :223-270