Influence of thermal boundary conditions on the dynamic behaviour of a rectangular single-phase natural circulation loop

被引:39
|
作者
Misale, M. [1 ]
Garibaldi, P. [1 ]
Tarozzi, L. [2 ]
Barozzi, G. S. [2 ]
机构
[1] Univ Genoa, Dipartimento Ingn Produz Termoenerget & Modelli M, I-16145 Genoa, Italy
[2] Univ Modena & Reggio Emilia, Dipartimento Ingn Meccan & Civile DIMeC, I-41100 Modena, Italy
关键词
Single-phase; Natural circulation; Flow instabilities; Stability analysis; Ultrasound Pulsed Doppler Velocimeter; FLOW;
D O I
10.1016/j.ijheatfluidflow.2010.12.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
Natural circulation of distilled water and FC43 has been experimentally investigated in a rectangular loop characterized by internal diameter of 30 mm and total length of 4.1 m. The aim of the present study is to analyse the influence of thermal boundary conditions on the flow regimes inside the pipes and on the stability of the system. The new aspect of the present research is the possibility of tuning the heat sink temperature in a range between -20 degrees C and +30 degrees C by means of a cryostat. This kind of analysis could be useful for the design of systems characterized by a wide range of environment temperatures, as for example for aerospatial applications. The other parameters investigated were the heat flux transferred to the fluid, which varied between 0.1 kW and 2.5 kW, and the thermo-physical properties of the working fluid. The system showed both stable and unstable behaviour. In particular, in the case of FC43 the loop was more unstable and it was characterized by higher velocities and frequencies compared to the case of distilled water. It was found that the stability threshold could be crossed by varying only the heat sink temperature, demonstrating the importance of this boundary condition on the dynamics of the system. Different flow regimes and fluid velocities were observed. In the case of steady-state flow, Vijayan's correlation (Vijayan et al., 2000) was tested and found to give good agreement with experimental data. Linear stability analysis was made following the Vijayan's model. In particular, the effect of heat sink temperature was considered in the dimensionless Stanton number based on the overall heat transfer coefficient at the heat sink. Finally, Ultrasound Pulsed Doppler Velocimeter (UPDV) was used on a natural circulation loop for the first time, and gave a preliminary validation of the traditional fluid velocity measurement method based on the frequency analysis. (c) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:413 / 423
页数:11
相关论文
共 50 条
  • [31] Unstable behavior of single-phase natural circulation under closed loop with connecting tube
    Satou, A
    Madarame, H
    Okamoto, K
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2001, 25 (06) : 429 - 435
  • [32] Investigations on single-phase natural circulation loop dynamics part 1: Model for simulating start-up from rest
    Naveen, Kumar
    Iyer, Kannan N.
    Doshi, J. B.
    Vijayan, P. K.
    PROGRESS IN NUCLEAR ENERGY, 2014, 76 : 148 - 159
  • [33] CFD investigation of fluid and heat transfer in a single-phase natural circulation toroidal loop
    Pinheiro, Larissa C.
    Alvim, Antonio Carlos M.
    NUCLEAR ENGINEERING AND DESIGN, 2023, 415
  • [34] Study of a Square Single-Phase Natural Circulation Loop Using the Lattice Boltzmann Method
    Bocanegra, Johan Augusto
    Marchitto, Annalisa
    Misale, Mario
    APPLIED MECHANICS, 2023, 4 (03): : 927 - 947
  • [35] An analytical model for the determination of stability boundaries in a natural circulation single-phase thermosyphon loop
    Maiani, M
    de Kruijf, WJM
    Ambrosini, W
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2003, 24 (06) : 853 - 863
  • [36] Convectional heat transfer characteristics of single-phase natural circulation flow in a narrow rectangular channel
    Tian C.
    Yan C.
    Cao X.
    Wang J.
    Tian W.
    Dai B.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2017, 38 (10): : 1554 - 1559
  • [37] Analysis of the effects of heat sink temperature on single-phase natural circulation loops behaviour
    Devia, F.
    Misale, M.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2012, 59 : 195 - 202
  • [38] Performance of a two-phase natural circulation in a rectangular loop
    Song, Jin Ho
    NUCLEAR ENGINEERING AND DESIGN, 2012, 245 : 125 - 130
  • [39] Investigations on single-phase natural circulation loop dynamics. Part 2: Role of wall constitutive laws
    Naveen, Kumar
    Iyer, Kannan N.
    Doshi, J. B.
    Vijayan, P. K.
    PROGRESS IN NUCLEAR ENERGY, 2014, 75 : 105 - 116
  • [40] Effects of various modeling assumptions on steady-state and transient performances of single-phase natural circulation loop
    Sahu, Mayaram
    Sarkar, Jahar
    Chandra, Laltu
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 124