No clinical difference between TiN-coated versus uncoated cementless CoCrMo mobile-bearing total knee arthroplasty; 10-year follow-up of a randomized controlled trial

被引:12
作者
Louwerens, Jan K. G. [1 ]
Hockers, Niels [1 ]
Achten, Gijs [1 ]
Sierevelt, Inger N. [1 ]
Nolte, Peter A. [1 ]
van Hove, Ruud P. [2 ]
机构
[1] Spaarne Gasthuis Hosp, Dept Orthopaed Surg, Hoofddorp, Netherlands
[2] Jeroen Bosch Hosp, Dept Orthopaed Surg, Shertogenbosch, Netherlands
关键词
Titanium-nitride; Patient outcome assessment; Coating; Total knee replacement; PROSTHETIC FEMORAL HEADS; TITANIUM-NITRIDE; POSTOPERATIVE PAIN; WEAR; REPLACEMENT; PERFORMANCE; OUTCOMES; BENEFIT;
D O I
10.1007/s00167-020-05997-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Improvement of biomechanical properties of cobalt-chromium-molybdenum (CoCrMo) implant surface and reduction of adhesive wear is achieved by titanium-nitride (TiN) coating in vitro. Less pain, higher postoperative outcome scores and a lower revision rate after TKA with a TiN-coated CoCrMo TKA compared with uncoated CoCrMo TKA after 10-year follow-up was hypothesized. Methods In a double-blinded RCT, 101 patients received a cementless mobile-bearing CoCrMo TKA, either TiN-coated or uncoated. The primary outcome measure was the visual analogue scale (VAS) score for pain and secondary outcome measures were the Knee Society Score (KSS), Oxford Knee Score (OKS), revision rate and adverse events. Patients were assessed at 6 weeks, 6 months, 1 year, 5 years and 10 years, postoperatively. Results 68 patients (67%) were available for 10-year follow-up. No difference was found in any of the assessed outcome measures with a mean decrease in VAS score (31.6 +/- 22.9) and a mean increase in OKS (10.9 +/- 8.4), KSS (29.3 +/- 31.4), KSSK (26.4 +/- 18.2) and KSSF (4.1 +/- 22.9). Overall revision rate was 7% (coated 6% vs uncoated 8%) without additional revision procedures between 5 and 10-year follow-up. Conclusions The in vitro potential benefits of TiN coating did not result in better clinical outcome when compared to an uncoated cementless TKA. Pain, functional outcome and revision rates were comparable after 10-year follow-up. TiN-coated cementless TKA provides comparable good long-term results, similar to uncoated cementless CoCrMo TKA. Netherlands Trial Register NL2887/NTR3033.
引用
收藏
页码:750 / 756
页数:7
相关论文
共 50 条
[41]   Total joint arthroplasty versus trapeziectomy for trapeziometacarpal joint arthritis: 5-year follow-up of a randomized controlled trial [J].
Bonhof-Jansen, Elske E. D. J. ;
de Jong, Tjeerd R. ;
Brink, Sander M. ;
de Wildt, Ramon P. ;
Werker, Paul M. N. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2025,
[42]   A randomized prospective study comparing mobile-bearing against fixed-bearing PFC Sigma cruciate-retaining total knee arthroplasties with ten-year minimum follow-up [J].
Powell, A. J. ;
Crua, E. ;
Chong, B. C. ;
Gordon, R. ;
McAuslan, A. ;
Pitto, R. P. ;
Clatworthy, M. G. .
BONE & JOINT JOURNAL, 2018, 100B (10) :1336-1344
[43]   Long-term clinical results of alumina ceramic medial pivot total knee arthroplasty: a 10-year follow-up study [J].
Ueyama, Hideki ;
Nakagawa, Shigeru ;
Kishimura, Yuichi ;
Minoda, Yukihide ;
Nakamura, Suguru ;
Koyanagi, Junichiro ;
Yamamura, Mitsuyoshi ;
Kadoya, Yoshinori .
ARTHROPLASTY, 2023, 5 (01)
[44]   Comparison of Mini-Midvastus and Conventional Total Knee Arthroplasty with Clinical and Radiographic Evaluation A Prospective Randomized Clinical Trial with 5-Year Follow-up [J].
Verburg, Hennie ;
Mathijssen, Nina M. C. ;
Niesten, Dieu-Donne ;
Verhaar, Jan A. N. ;
Pilot, Peter .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (12) :1014-1022
[45]   Mid-term clinical and radiological results do not differ between fixed- and mobile-bearing total knee arthroplasty using titanium-nitride-coated posterior-stabilized prostheses: a prospective randomized controlled trial [J].
Cheol Hee Park ;
Se Gu Kang ;
Dae Kyung Bae ;
Sang Jun Song .
Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 :1165-1173
[46]   Twelve-Year Follow-Up of Navigated Computer-Assisted Versus Conventional Total Knee Arthroplasty A Prospective Randomized Comparative Trial [J].
Cip, Johannes ;
Obwegeser, Florian ;
Benesch, Thomas ;
Bach, Christian ;
Ruckenstuhl, Paul ;
Martin, Arno .
JOURNAL OF ARTHROPLASTY, 2018, 33 (05) :1404-1411
[47]   Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Clinical and Radiographic Outcomes in Total Knee Arthroplasty at 10-Year Follow-up [J].
Remily, Ethan A. ;
Wilkie, Wayne A. ;
Mohamed, Nequesha S. ;
Smith, Langan S. ;
Malkani, Arthur L. ;
Jaggard, Charles E. ;
Kolisek, Frank R. ;
Monesmith, Eric A. ;
Nace, James ;
Delanois, Ronald E. .
ORTHOPEDICS, 2023, 46 (02) :113-117
[48]   No Difference in Clinical and Radiologic Outcomes After Total Knee Arthroplasty With a New Ultra-Congruent Mobile Bearing System and Rotating Platform Mobile Bearing Systems After Minimum 5-Year Follow-Up [J].
Ko, Young-Bong ;
Jang, Eui-Chan ;
Park, Sang-Min ;
Kim, Seong Hwan ;
Kwak, Yoon-Ho ;
Lee, Han-Jun .
JOURNAL OF ARTHROPLASTY, 2015, 30 (03) :379-383
[49]   No difference in 5-year survivorship between cemented versus cementless total knee arthroplasty in a cohort of 5266 patients using a deep-dish mobile bearing implant [J].
Manchec, Ophelie ;
Berard, Emilie ;
Pailhe, Regis ;
Lustig, Sebastien ;
Cavaignac, Etienne .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2025,
[50]   Long-Term Comparison Study of Patella Resurfacing Versus Non-resurfacing in Total Knee Arthroplasty with Minimum 10-Year Follow-Up [J].
Thilak, Jai ;
Mohan, Vipin .
INDIAN JOURNAL OF ORTHOPAEDICS, 2020, 54 (05) :631-638