Fast and efficient size-based separations of polymers using ultra-high-pressure liquid chromatography

被引:49
|
作者
Uliyanchenko, Elena [1 ,2 ]
Schoenmakers, Peter J. [1 ]
van der Wal, Sjoerd [1 ,3 ]
机构
[1] Univ Amsterdam, Fac Sci, Analyt Chem Grp, vant Hoff Inst Mol Sci, NL-1098 XH Amsterdam, Netherlands
[2] Dutch Polymer Inst, NL-5600 AX Eindhoven, Netherlands
[3] DSM Resolve, NL-6160 MD Geleen, Netherlands
关键词
Ultra-high-pressure liquid chromatography; Fast size-exclusion chromatography; Hydrodynamic chromatography; Polystyrene standards; Slalom chromatography; Deborah number; COLUMN HYDRODYNAMIC CHROMATOGRAPHY; NONPOROUS SILICA PARTICLES; VISCOUS HEAT DISSIPATION; PACKED CAPILLARY COLUMNS; MM ID COLUMNS; EXCLUSION CHROMATOGRAPHY; TEMPERATURE-GRADIENTS; MASS-SPECTROMETRY; POROUS PARTICLES; PERFORMANCE;
D O I
10.1016/j.chroma.2011.01.053
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ultra-high-pressure liquid chromatography (UHPLC) has great potential for the separations of both small molecules and polymers. However, the implementation of UHPLC for the analysis of macromolecules invokes several problems. First, to provide information on the molecular-weight distribution of a polymer, size-exclusion (SEC) columns with specific pore sizes are needed. Development of packing materials with large pore diameters and pore volumes which are mechanically stable at ultra-high-pressures is a technological challenge. Additionally, narrow-bore columns are typically used in UHPLC to minimize the problem of heat dissipation. Such columns pose stringent requirements on the extra-column dispersion, especially for large (slowly diffusing) molecules. Finally, UHPLC conditions generate high shear rates, which may affect polymer chains. The possibilities and limitations of UHPLC for size-based separations of polymers are addressed in the present study. We demonstrate the feasibility of conducting efficient and very fast size-based separations of polymers using conventional and wide-bore (4.6 mm I.D.) UHPLC columns. The wider columns allow minimization of the extra-column contribution to the observed peak widths down to an insignificant level. Reliable SEC separations of polymers with molecular weights up to ca. 50 kDa are achieved within less than 1 min at pressures of about 66 MPa. Due to the small particles used in UHPLC it is possible to separate high-molecular-weight polymers (50 kDa <= M-r <= 1-3 MDa, upper limit depends on the flow rate) in the hydrodynamic-chromatography (HOC) mode. Very fast and efficient HOC separations are presented. For very large polymer molecules (typically larger than several MDa, depending on the flow rate) two chromatographic peaks are observed. This is attributed to the onset of molecular deformation at high shear rates and the simultaneous actions of hydrodynamic and slalom chromatography. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1509 / 1518
页数:10
相关论文
共 50 条
  • [1] Deformation and degradation of polymers in ultra-high-pressure liquid chromatography
    Uliyanchenko, Elena
    van der Wal, Sjoerd
    Schoenmakers, Peter J.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (39) : 6930 - 6942
  • [2] Ultra-high-pressure liquid chromatography (UHPLC) in method development
    Dong, Michael W.
    Zhang, Kelly
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 63 : 21 - 30
  • [3] Coupling ultra-high-pressure liquid chromatography with mass spectrometry
    Guillarme, Davy
    Schappler, Julie
    Rudaz, Serge
    Veuthey, Jean-Luc
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (01) : 15 - 27
  • [4] Further investigations of the effect of pressure on retention in ultra-high-pressure liquid chromatography
    Fallas, Morgane M.
    Neue, Uwe D.
    Hadley, Mark R.
    McCalley, David V.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (03) : 276 - 284
  • [5] Complete temperature profiles in ultra-high-pressure liquid chromatography columns
    Gritti, Fabrice
    Guiochon, Georges
    ANALYTICAL CHEMISTRY, 2008, 80 (13) : 5009 - 5020
  • [6] Fast Analytical Separations with High-Pressure Liquid Chromatography
    Bender, Trandon A.
    Booth, Jenacee
    Walker, Edward B.
    JOURNAL OF CHEMICAL EDUCATION, 2013, 90 (08) : 1061 - 1063
  • [7] Fast and efficient separations using reversed phase liquid chromatography
    Wu, Naijun
    Thompson, Richard
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (7-8) : 949 - 988
  • [8] Fast log P determination by ultra-high-pressure liquid chromatography coupled with UV and mass spectrometry detections
    Henchoz, Yveline
    Guillarme, Davy
    Martel, Sophie
    Rudaz, Serge
    Veuthey, Jean-Luc
    Carrupt, Pierre-Alain
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (07) : 1919 - 1930
  • [9] Fast log P determination by ultra-high-pressure liquid chromatography coupled with UV and mass spectrometry detections
    Yveline Henchoz
    Davy Guillarme
    Sophie Martel
    Serge Rudaz
    Jean-Luc Veuthey
    Pierre-Alain Carrupt
    Analytical and Bioanalytical Chemistry, 2009, 394 : 1919 - 1930
  • [10] The impact of pressure and frictional heating on retention, selectivity and efficiency in ultra-high-pressure liquid chromatography
    McCalley, David V.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 63 : 31 - 43