A computer-assisted measurement technique to assess bone proximal to oral implants on intraoral radiographs

被引:33
作者
Wyatt, CCL
Bryant, SR
Avivi-Arber, L
Chaytor, DV
Zarb, GA
机构
[1] Univ British Columbia, Fac Dent, Dept Oral Hlth Sci, Vancouver, BC V6T 1Z3, Canada
[2] Univ Toronto, Dept Prosthodont, Toronto, ON, Canada
[3] Dalhousie Univ, Dept Prosthodont, Halifax, NS, Canada
关键词
implantology; oral implants; radiography; bone measurement;
D O I
10.1034/j.1600-0501.2001.012003225.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A computer-assisted measurement technique for measuring bone levels proximal (mesial and distal) to oral implants imaged on standardized intraoral radiographs offers promise for accuracy and reliability. There were no differences between bone measurements made directly from bone proximal to implants placed in a dry mandible and those resulting from the computer-assisted measurement technique. In addition, there were no differences between measurements made of bone proximal to oral implants in vivo using the microscope and the computer techniques. The computer technique had a low intra- and inter-operator variability, and operators found fewer "unreadable" sites compared to the microscope technique. The computer-assisted measurement of bone levels proximal to oral implants on standardized intraoral radiographs offers accuracy and reliability.
引用
收藏
页码:225 / 229
页数:5
相关论文
共 22 条
[11]  
Hollender L, 1980, Dentomaxillofac Radiol, V9, P91
[12]   A NEW METHOD FOR THE COMPARISON OF BONE LOSS MEASUREMENTS ON NON-STANDARDIZED RADIOGRAPHS [J].
JEFFCOAT, MK ;
JEFFCOAT, RL ;
WILLIAMS, RC .
JOURNAL OF PERIODONTAL RESEARCH, 1984, 19 (04) :434-440
[13]  
Levy D, 1997, INT J ORAL MAX IMPL, V12, P541
[14]   A 5-year prospective clinical study of Astra Tech dental implants supporting fixed bridges or overdentures in the edentulous mandible [J].
Makkonen, TA ;
Holmberg, S ;
Niemi, L ;
Olsson, C ;
Tammisalo, T ;
Peltola, J .
CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (06) :469-475
[15]   A COMPARISON OF METHODS TO ASSESS MARGINAL BONE HEIGHT AROUND ENDOSSEOUS IMPLANTS [J].
MEIJER, HJA ;
STEEN, WHA ;
BOSMAN, F .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1993, 20 (04) :250-253
[16]   Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro- and microstructure [J].
Norton, MR .
CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (02) :91-99
[17]   Standardization of radiographs for mandibular implant-supported overdentures: review and innovation [J].
Payne, AGT ;
Solomons, YF ;
Lownie, JF .
CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (04) :307-319
[18]  
SEWERIN IP, 1990, SCAND J DENT RES, V98, P428
[19]  
Siddiqui A A, 1995, Implant Dent, V4, P85, DOI 10.1097/00008505-199505000-00002
[20]   COMPUTER CORRECTION OF PROJECTIVE DISTORTIONS IN DENTAL RADIOGRAPHS [J].
WEBBER, RL ;
RUTTIMANN, UE ;
GROENHUIS, RAJ .
JOURNAL OF DENTAL RESEARCH, 1984, 63 (08) :1032-1036