Correlation between concrete cracks and corrosion characteristics of steel reinforcement in pre-cracked plain and fibre-reinforced concrete beams

被引:52
|
作者
Chen, E. [1 ]
Berrocal, Carlos G. [1 ,2 ]
Lofgren, Ingemar [1 ,2 ]
Lundgren, Karin [1 ]
机构
[1] Chalmers Univ Technol, Div Struct Engn, S-41296 Gothenburg, Sweden
[2] Thomas Concrete Grp AB, Sodra Vagen 28, S-41254 Gothenburg, Sweden
关键词
Pitting corrosion; 3D-scanning; Fibre-reinforced concrete; Transverse cracks; Corrosion-induced cracks; CHLORIDE-INDUCED CORROSION; WIDTH; RESISTIVITY; BEHAVIOR; COVER; RATES;
D O I
10.1617/s11527-020-01466-z
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents results on corrosion characteristics of 66 rebars extracted from un- and pre-cracked plain concrete and fibre-reinforced concrete (FRC) beams suffering from corrosion for more than 3 years. The influences of fibre reinforcement, flexural cracks, corrosion-induced cracks and loading condition on the maximum local corrosion level (defined as the maximum cross-sectional area loss percentage) and pit morphology were examined. With 3D-scanning, the corrosion characteristics were analysed, and pit types were classified based on the maximum local corrosion level and geometric parameters of pits. Corrosion pits were observed near some flexural cracks, while the bars at other cracks were free from corrosion. Most rebars in FRC had less maximum local corrosion level than those in plain concrete under the same loading condition and maximum flexural crack width. However, the maximum local corrosion level was not dependent on the maximum flexural crack width (0.1 and 0.4 mm). Longitudinal cracks (corrosion-induced cracks) aggravated the total steel loss and changed the pit morphology by promoting the pit length development. However, longitudinal cracks did not always form, even with severe pitting corrosion. A hypothesis about the time-dependent interplay between transverse and longitudinal cracks and corrosion development was proposed. Further studies on predicting the pitting corrosion evolution and experimental work on specimens exposed for longer periods are needed to understand and quantify the long-term durability of concrete structures reinforced with both conventional reinforcing bars and fibres.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Correlation between concrete cracks and corrosion characteristics of steel reinforcement in pre-cracked plain and fibre-reinforced concrete beams
    E. Chen
    Carlos G. Berrocal
    Ingemar Löfgren
    Karin Lundgren
    Materials and Structures, 2020, 53
  • [2] 25 years of field exposure of pre-cracked concrete beams; combined impact of spacers and cracks on reinforcement corrosion
    Geiker, Mette
    Danner, Tobias
    Michel, Alexander
    Revert, Andres Belda
    Linderoth, Oskar
    Hornbostel, Karla
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 286
  • [3] Experimental investigation of the relation between damage at the concrete-steel interface and initiation of reinforcement corrosion in plain and fibre reinforced concrete
    Michel, A.
    Solgaard, A. O. S.
    Pease, B. J.
    Geiker, M. R.
    Stang, H.
    Olesen, J. F.
    CORROSION SCIENCE, 2013, 77 : 308 - 321
  • [4] Flexural Fatigue Deterioration Behaviour of Pre-cracked Fibre Reinforced Concrete
    Fataar, Humaira
    Makara, Nyane Patricia
    Combrinck, Riaan
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON CONCRETE REPAIR, REHABILITATION AND RETROFITTING, ICCRRR 2024, 2025, 59 : 320 - 329
  • [5] Numerical analysis of reinforced concrete beams pre-cracked reinforced by composite materials
    Benaoum, Fatima
    Khelil, Foudil
    Benhamena, Ali
    FRATTURA ED INTEGRITA STRUTTURALE, 2020, 14 (54): : 282 - 296
  • [6] Life cycle assessment of steel fibre-reinforced concrete beams
    Asare, Gideon Osei
    Barnett, Stephanie
    Awinda, Kenneth
    Martinson, Brett
    COGENT ENGINEERING, 2024, 11 (01):
  • [7] BEHAVIOUR OF FIBRE-REINFORCED CONCRETE BEAMS WITH DIFFERENT REINFORCEMENT RATIOS
    Dancygier, Avraham N.
    Berkover, Erez
    FIB SYMPOSIUM PRAGUE 2011: CONCRETE ENGINEERING FOR EXCELLENCE AND EFFICIENCY, VOLS 1 AND 2, 2011, : 1133 - 1136
  • [8] Shear strengthening design of pre-cracked reinforced concrete beams using bonded and bolted steel plates
    Rakib, Md. Abdur
    Morshed, Abu Zakir
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2023, 24 (02) : 159 - 172
  • [9] Flexural fatigue performance of pre-cracked steel fibre reinforced concrete: Experimental program and design-oriented approach
    Carlesso, Debora Martinello
    Cavalaro, Sergio Henrique Pialarissi
    Bairan, Jesus Miguel
    de la Fuente, Albert
    CONSTRUCTION AND BUILDING MATERIALS, 2025, 467
  • [10] Flexural fatigue of pre-cracked plastic fibre reinforced concrete: Experimental study and numerical modeling
    Martinello Carlesso, Debora
    Cavalaro, Sergio
    de la Fuente, Albert
    CEMENT & CONCRETE COMPOSITES, 2021, 115