Breast cancer screening using synthesized two-dimensional mammography: A systematic review and meta-analysis

被引:16
作者
Zeng, Baoqi [1 ]
Yu, Kai [1 ]
Gao, Le [2 ]
Zeng, Xueyang [3 ]
Zhou, Qingxin [3 ]
机构
[1] Peking Univ, Binhai Hosp, Dept Sci & Educ, Tianjin, Peoples R China
[2] Univ Hong Kong, Dept Pharmacol & Pharm, Hong Kong, Peoples R China
[3] Peking Univ, Sch Publ Hlth, Hlth Sci Ctr, Dept Epidemiol & Biostat, Beijing, Peoples R China
关键词
Breast cancer; Cancer screening; Digital breast tomosynthesis; Meta-analysis; RECONSTRUCTED PROJECTION IMAGES; SYNTHETIC 2D MAMMOGRAPHY; DIGITAL MAMMOGRAPHY; TOMOSYNTHESIS; PERFORMANCE; COMBINATION; IMPLEMENTATION; MULTICENTER; INTERVAL;
D O I
10.1016/j.breast.2021.07.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We conducted a systematic review and meta-analysis to compare the screening performance of synthesized mammography (SM) plus digital breast tomosynthesis (DBT) with digital mammography (DM) plus DBT or DM alone. Methods: Medline, Embase, Web of Science, and the Cochrane Library databases were searched from January 2010 to January 2021. Eligible population-based studies on breast cancer screening comparing SM/DBT with DM/DBT or DM in asymptomatic women were included. A random-effect model was used in this meta-analysis. Data were summarized as risk differences (RDs), with 95 % confidence intervals (CIs). Results: Thirteen studies involving 1,370,670 participants were included. Compared with DM/DBT, screening using SM/DBT had similar breast cancer detection rate (CDR) (RD =-0.1/1000 screens, 95 % CI =-0.4 to 0.2, p = 0.557, I-2 = 0 %), but lower recall rate (RD =-0.56 %, 95 % CI =-1.03 to-0.08, p = 0.022, I-2 = 90 %) and lower biopsy rate (RD =-0.33 %, 95 % CI =-0.56 to-0.10, p = 0.005, I-2 = 78 %). Compared with DM, SM/DBT improved CDR (RD = 2.0/1000 screens, 95 % CI = 1.4 to 2.6, p < 0.001, I-2 = 63 %) and reduced recall rate (RD =-0.95 %, 95 % CI =-1.91 to-0.002, p = 0.049, I-2 = 99 %). However, SM/DBT and DM had similar interval cancer rate (ICR) (RD = 0.1/1000 screens, 95 % CI =-0.6 to 0.8, p = 0.836, I-2 = 71 %) and biopsy rate (RD =-0.05 %, 95 % CI =-0.35 to 0.24, p = 0.727, I-2 = 93 %). Conclusions: Screening using SM/DBT has similar breast cancer detection but reduces recall and biopsy when compared with DM/DBT. SM/DBT improves CDR when compared with DM, but they have little difference in ICR. SM/DBT could replace DM/DBT in breast cancer screening to reduce radiation dose. (C) 2021 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:270 / 278
页数:9
相关论文
共 50 条
  • [2] Interval breast cancer rates for tomosynthesis vs mammography population screening: a systematic review and meta-analysis of prospective studies
    Libesman, Sol
    Li, Tong
    Marinovich, M. Luke
    Seidler, Anna Lene
    Tagliafico, Alberto Stefano
    Houssami, Nehmat
    EUROPEAN RADIOLOGY, 2025, 35 (03) : 1478 - 1489
  • [3] Digital breast tomosynthesis (DBT) plus synthesised two-dimensional mammography (s2D) in breast cancer screening is associated with higher cancer detection and lower recalls compared to digital mammography (DM) alone: results of a systematic review and meta-analysis
    Heywang-Koebrunner, Sylvia H.
    Jaensch, Alexander
    Hacker, Astrid
    Weinand, Sina
    Vogelmann, Tobias
    EUROPEAN RADIOLOGY, 2022, 32 (04) : 2301 - 2312
  • [4] Performance of Digital Breast Tomosynthesis, Synthetic Mammography, and Digital Mammography in Breast Cancer Screening: A Systematic Review and Meta-Analysis
    Alabousi, Mostafa
    Wadera, Akshay
    Al-Ghita, Mohammed Kashif
    Al-Ghetaa, Rayeh Kashef
    Salameh, Jean-Paul
    Pozdnyakov, Alex
    Zha, Nanxi
    Samoilov, Lucy
    Sharifabadi, Anahita Dehmoobad
    Sadeghirad, Behnam
    Freitas, Vivianne
    McInnes, Matthew D. F.
    Alabousi, Abdullah
    JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2021, 113 (06): : 680 - 690
  • [5] Mammography diagnosis of breast cancer screening through machine learning: a systematic review and meta-analysis
    Liu, Junjie
    Lei, Jiangjie
    Ou, Yuhang
    Zhao, Yilong
    Tuo, Xiaofeng
    Zhang, Baoming
    Shen, Mingwang
    CLINICAL AND EXPERIMENTAL MEDICINE, 2023, 23 (06) : 2341 - 2356
  • [6] Breast Cancer Screening Using Tomosynthesis or Mammography: A Meta-analysis of Cancer Detection and Recall
    Marinovich, M. Luke
    Hunter, Kylie E.
    Macaskill, Petra
    Houssami, Nehmat
    JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2018, 110 (09): : 942 - 949
  • [7] Diagnostic Value of Contrast-Enhanced Spectral Mammography for Screening Breast Cancer: Systematic Review and Meta-analysis
    Zhu, Xiao
    Huang, Jun-ming
    Zhang, Kun
    Xia, Long-jie
    Feng, Lan
    Yang, Ping
    Zhang, Meng-ya
    Xiao, Wei
    Lin, Hui-xia
    Yu, Ying-hua
    CLINICAL BREAST CANCER, 2018, 18 (05) : E985 - E995
  • [8] Tomosynthesis with synthesised two-dimensional mammography yields higher cancer detection compared to digital mammography alone, also in dense breasts and in younger women: A systematic review and meta-analysis
    Heywang-Kobrunner, Sylvia-H.
    Jansch, Alexander
    Hacker, Astrid
    Weinand, Sina
    Vogelmann, Tobias
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 152 : 1 - 11
  • [9] Benefit of adding digital breast tomosynthesis to digital mammography for breast cancer screening focused on cancer characteristics: a meta-analysis
    Yun, Seong Jong
    Ryu, Chang-Woo
    Rhee, Sun Jung
    Ryu, Jung Kyu
    Oh, Ji Young
    BREAST CANCER RESEARCH AND TREATMENT, 2017, 164 (03) : 557 - 569
  • [10] Effect of rurality on screening for breast cancer: a systematic review and meta-analysis comparing mammography
    Leung, J.
    McKenzie, S.
    Martin, J.
    McLaughlin, D.
    RURAL AND REMOTE HEALTH, 2014, 14 (02):