Concrete pavements curing evaluation with non-destructive tests

被引:19
作者
Joshaghani, Alireza [1 ]
Zollinger, Dan G. [1 ]
机构
[1] Texas A&M Univ, Zachry Dept Civil Engn, College Stn, TX 77843 USA
关键词
Concrete; Pavement; Ground penetrating radar (GPR); Effectiveness index (EI); Percometer; Dielectric constant (DC); Shrinkage; Curing; GROUND-PENETRATING RADAR; HIGH-PERFORMANCE CONCRETE; SITU DIELECTRIC-CONSTANT; GPR; SHRINKAGE; FIBER; RESISTANCE;
D O I
10.1016/j.conbuildmat.2017.06.110
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study was completed by the Texas A&M Transportation Institute (TTI). The ground penetrating radar (GPR) technology and percometer were implemented for newly constructed highways. The GPR identifies the subsurface condition, which permits the user to determine the moisture availability for potential concrete curing. For this purpose, a GPR data acquisition program and data analysis system were developed by utilizing antenna. A combination of GPR information evaluation and curing quality evaluation is performed to diagnose the effectiveness of the applied curing compounds in terms of the moisture retention capability. Dielectric constant (DC) Measurements were also taken on concrete specimens to indicate the free moisture content of the surface concrete. The new procedure consists of using measured relative humidity and temperature to calculate an Effectiveness Index (EI). EI and DC measurements indicate potentials to differentiate the curing quality of rigid pavement construction. Researchers examined the relationship between the Non-Destructive Testing (NDT) data and the actual concrete properties to develop "acceptability of quality" limits based upon the NDT data. The field investigations were conducted on two continuously reinforced concrete paving (CRCP) projects' microfiber and internal curing mixtures. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1250 / 1262
页数:13
相关论文
共 40 条
[1]   In situ measurements of hot-mix asphalt dielectric properties [J].
Al-Qadi, IL ;
Lahouar, S ;
Loulizi, A .
NDT & E INTERNATIONAL, 2001, 34 (06) :427-434
[2]  
[Anonymous], 2001, BULLETIN
[3]  
[Anonymous], 2006, GSSI HDB RAD INSP CO
[4]  
[Anonymous], 2014, C157C157M08 ASTM
[5]  
[Anonymous], 2016, C33C33M16E1 ASTM
[6]  
[Anonymous], 2014, ASTM C305
[7]  
[Anonymous], 2016, C150C150M16E1 ASTM
[8]  
[Anonymous], 2015, Standard test method for relative density (specific gravity) and absorption of fine aggregate, DOI 10.1520/C0128-15
[9]   Improved concrete bridge deck evaluation using GPR by accounting for signal depth-amplitude effects [J].
Barnes, Christopher L. ;
Trottier, Jean-Francois ;
Forgeron, Dean .
NDT & E INTERNATIONAL, 2008, 41 (06) :427-433
[10]   Determination of water content in fresh concrete mix based on relative dielectric constant measurement [J].
Chen, Wei ;
Shen, Peiliang ;
Shui, Zhonghe .
CONSTRUCTION AND BUILDING MATERIALS, 2012, 34 :306-312