Backscatter-difference Measurements of Cancellous Bone Using an Ultrasonic Imaging System

被引:9
|
作者
Hoffmeister, Brent K. [1 ]
Smathers, Morgan R. [1 ]
Miller, Catherine J. [1 ]
McPherson, Joseph A. [1 ]
Thurston, Cameron R. [1 ]
Spinolo, P. Luke [1 ]
Lee, Sang-Rok [2 ]
机构
[1] Rhodes Coll, Dept Phys, 2000 North Pkwy, Memphis, TN 38112 USA
[2] New Mexico State Univ, Dept Kinesiol & Dance, Las Cruces, NM 88003 USA
基金
美国国家卫生研究院;
关键词
ultrasound; backscatter; cancellous bone; osteoporosis; PULSE-ECHO TECHNIQUE; ATTENUATION; METHODOLOGY; TISSUE;
D O I
10.1177/0161734615603703
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Backscatter-difference measurements may be used to detect changes in bone caused by osteoporosis. The backscatter-difference technique measures the power difference between two portions of an ultrasonic backscatter signal. The goal of this study is to evaluate the feasibility of using an ultrasonic imaging system to perform backscatter-difference measurements of bone. Ultrasonic images and backscatter signals were acquired from 24 specimens of human cancellous bone. The signals were analyzed in the frequency domain to determine the normalized mean backscatter-difference (nMBD) and in the time domain to determine the normalized backscatter amplitude ratio (nBAR). The images were analyzed to determine the normalized pixel value difference (nPVD), which measures the difference in average pixel brightness between regions of interest placed at two different depths in the image. All three parameters were found to increase with bone mineral density. The signal-based parameters, nMBD and nBAR, correlated well with bone mineral density, yielding linear correlation coefficients that ranged from 0.74 to 0.87. The image based parameter, nPVD, performed somewhat less well, yielding correlation coefficients that ranged from 0.42 to 0.81. These results suggest that ultrasonic imaging systems may be used to perform backscatter-difference measurements for the purpose of ultrasonic bone assessment.
引用
收藏
页码:285 / 297
页数:13
相关论文
共 50 条
  • [1] Effect of the cortex on ultrasonic backscatter measurements of cancellous bone
    Hoffmeister, Brent K.
    Holt, Andrew P.
    Kaste, Sue C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (19): : 6243 - 6255
  • [2] Characterization of Cancellous Bone Microstructure by Using Ultrasonic Apparent Backscatter Imaging
    Yang, Baiding
    Ta, Dean
    Huang, Kai
    Wang, Weiqi
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 153 - 157
  • [3] Effect of transducer position on ultrasonic backscatter measurements of cancellous bone
    Hoffmeister, Brent K.
    Lawler, Blake C.
    Viano, Ann M.
    Mobley, Joel
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 154 (05): : 2858 - 2868
  • [5] Ultrasonic backscatter difference measurements of cancellous bone from the human femur: Relation to bone mineral density and microstructure
    Hoffmeister, Brent K.
    Viano, Ann M.
    Huang, Jinsong
    Fairbanks, Luke C.
    Ebron, Sheldon C.
    Moore, Joshua T.
    Ankersen, Jordan P.
    Huber, Matthew T.
    Diaz, Abel A.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2018, 143 (06): : 3642 - 3653
  • [6] Effect of gate choice on backscatter difference measurements of cancellous bone
    Hoffmeister, Brent K.
    Viano, Ann M.
    Fairbanks, Luke C.
    Ebron, Sheldon C.
    McPherson, Joseph A.
    Huber, Matthew T.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2017, 142 (02): : 540 - 550
  • [7] Ultrasonic backscatter and attenuation of cancellous bone
    Deligianni, D
    Apostolopoulos, K
    ADVANCES IN SCATTERING AND BIOMEDICAL ENGINEERING, PROCEEDINGS, 2004, : 504 - 511
  • [8] Ultrasonic characterization of cancellous bone using apparent integrated backscatter
    Hoffmeister, B. K.
    Jones, C. I., III
    Caldwell, G. J.
    Kaste, S. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11): : 2715 - 2727
  • [9] Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements:: Relationships to density and microstructure
    Chaffaî, S
    Peyrin, F
    Nuzzo, S
    Porcher, R
    Berger, G
    Laugier, P
    BONE, 2002, 30 (01) : 229 - 237
  • [10] INFLUENCE OF MICROARCHITECTURE ON CANCELLOUS BONE ULTRASONIC BACKSCATTER
    Apostolopoulos, C.
    Deligianni, D.
    ADVANCED TOPICS IN SCATTERING AND BIOMEDICAL ENGINEERING, 2008, : 211 - 217