Annular Heating Furnace Temperature Control Based on the Fuzzy-PID Algorithm and Cascade Double-cross Limiting Control

被引:1
作者
Li Tinggui [1 ]
Li Gang [1 ]
机构
[1] Luzhou Vocat & Tech Coll, Luzhou 646005, Sichuan, Peoples R China
来源
MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY | 2014年 / 556-562卷
关键词
temperature control; annular heating furnace; Fuzzy-PID Algorithm; cascade double-cross limiting control;
D O I
10.4028/www.scientific.net/AMM.556-562.2478
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Annular heating furnace temperature control is a typical and complex industrial process control system, with the characteristics of multivariable, time-varying parameters, nonlinear, coupling, large inertia and pure delay, so it is difficult to obtain satisfactory control effect when using conventional PID control. In view of the above problems, adopting fuzzy PID algorithm and cascade double-cross limiting control, combustion control effect is greatly improved, self-tuning of PID parameters is realized, and control quality is enhanced. The experimental results show that, fuzzy PID control shows good dynamic and steady performance, its control effect is significantly improved when compared with conventional PID control, and it has better overall performance.
引用
收藏
页码:2478 / 2482
页数:5
相关论文
共 7 条
  • [1] Beichuan Deng, 2007, COMPUTER DEV APPL, V20, P69
  • [2] Cai Qiao-fang, 1996, REHEATING FURNACE
  • [3] Chai Tian-you, 2000, ACTA AUTOMATICA SINI, V26, P537
  • [4] [陈海耿 Chen Haigeng], 2006, [钢铁, Iron and Steel], V41, P75
  • [5] Ditzhuijzen V, 2002, P 2002 IEEE INT C CO, P361
  • [6] Xiao Xiao, 2012, ANNULAR FURNACE TEMP
  • [7] Zhenyu Huo, 2011, CONTROL INSTRUMENTS, V38, p[1136, 1157]