A New Two-Pulse Synthesis Model for Digital Volume Pulse Signal Analysis

被引:30
作者
Goswami, Dharitri [1 ]
Chaudhuri, Koel [1 ]
Mukherjee, Jayanta [2 ]
机构
[1] Indian Inst Technol, Sch Med Sci & Technol, Kharagpur 721302, W Bengal, India
[2] Indian Inst Technol, Dept Comp Sci & Engn, Kharagpur 721302, W Bengal, India
关键词
Photoplethysmograph; Digital volume pulse; Rayleigh pulse; Two-pulse synthesis; CONTOUR ANALYSIS; WAVE REFLECTION; ARTERIAL; PHOTOPLETHYSMOGRAPHY; QUANTIFICATION; STIFFNESS; PRESSURE; AORTA;
D O I
10.1007/s10558-010-9098-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Analysis of digital volume pulse (DVP) signal measured by photoplethysmograph (PPG) technique is a low cost non-invasive method of obtaining vital information related to arterial conditions. In this paper, we present a new two-pulse synthesis (TPS) model for deriving arterial parameters, useful for noninvasive assessment of human vascular health. The model is based on the use of Rayleigh function. Relevance of the proposed model is established by applying it on a sample set of 113 PPG signals, obtained form healthy and treated hypertensive subjects. The TPS model compares well with the conventional methods in determining parameters such as pulse transit time or foot-to-foot delay (D), reflection index (RI), stiffness index (SI) and pulse wave velocity (PWV). A new parameter, viz. differential pulse spread (DPS) has also been introduced for DVP signals using the model. The differential pulse spread provides a new dimension to estimate the process of arterial degeneration.
引用
收藏
页码:109 / 117
页数:9
相关论文
共 22 条
  • [1] Photoplethysmography and its application in clinical physiological measurement
    Allen, John
    [J]. PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) : R1 - R39
  • [2] The finger volume pulse and assessment of arterial properties
    Avolio, A
    [J]. JOURNAL OF HYPERTENSION, 2002, 20 (12) : 2341 - 2343
  • [3] Digital pulse contour analysis: investigating age-dependent indices of arterial compliance
    Brumfield, AM
    Andrew, ME
    [J]. PHYSIOLOGICAL MEASUREMENT, 2005, 26 (05) : 599 - 608
  • [4] GENESIS OF PULSE CONTOURS OF DISTAL LEG ARTERIES IN MAN
    BUSSE, R
    WETTERER, E
    BAUER, RD
    PASCH, T
    SUMMA, Y
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1975, 360 (01): : 63 - 79
  • [5] Photoplethysmographic assessment of pulse wave reflection -: Blunted response to endothelium-dependent beta2-adrenergic vasodilation in type II diabetes mellitus
    Chowienczyk, PJ
    Kelly, RP
    MacCallum, H
    Millasseau, SC
    Andersson, TLG
    Gosling, RG
    Ritter, JM
    Änggård, EE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (07) : 2007 - 2014
  • [6] HLIMOMENKO I, 2007, P 29 ANN INT C IEEE
  • [7] Hlimonenko I., 2003, Measurement Science Review, V3, P49
  • [8] Non-invasive Studies on Age Related Parameters Using a Blood Volume Pulse Sensor
    Jayasree, V. K.
    Sandhya, T., V
    Radhakrishnan, P.
    [J]. MEASUREMENT SCIENCE REVIEW, 2008, 8 (04): : 82 - 86
  • [9] Jyotsna M, 2008, CLIN MED INSIGHTS-CA, V1, P153
  • [10] Left ventricular mass and arterial compliance: relation to coronary heart disease and its risk factors in South Indian adults
    Kumaran, K
    Fall, CHD
    Martyn, CN
    Vijayakumar, M
    Stein, CE
    Shier, R
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2002, 83 (01) : 1 - 9