An adversarial machine learning based approach and biomechanically-guided validation for improving deformable image registration accuracy between a planning CT and cone-beam CT for adaptive prostate radiotherapy applications

被引:1
|
作者
Santhanam, Anand P. [1 ]
Lauria, Michael [1 ]
Stiehl, Brad [1 ]
Elliott, Daniel [2 ]
Seshan, Saty [2 ]
Hsieh, Scott [1 ]
Cao, Minsong [1 ]
Low, Daniel [1 ]
机构
[1] Univ Calif Los Angeles, Dept Radiat Oncol, Los Angeles, CA 90024 USA
[2] SegAna LLC, Orlando, FL USA
来源
MEDICAL IMAGING 2020: IMAGE PROCESSING | 2021年 / 11313卷
基金
美国国家科学基金会;
关键词
HEAD;
D O I
10.1117/12.2550493
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Adaptive radiotherapy is an effective procedure for the treatment of cancer, where the daily anatomical changes in the patient are quantified, and the dose delivered to the tumor is adapted accordingly. Deformable Image Registration (DIR) inaccuracies and delays in retrieving and registering on-board cone beam CT (CBCT) image datasets from the treatment system with the planning kilo Voltage CT (kVCT) have limited the adaptive workflow to a limited number of patients. In this paper, we present an approach for improving the DIR accuracy using a machine learning approach coupled with biomechanically guided validation. For a given set of 11 planning prostate kVCT datasets and their segmented contours, we first assembled a biomechanical model to generate synthetic abdominal motions, bladder volume changes, and physiological regression. For each of the synthetic CT datasets, we then injected noise and artifacts in the images using a novel procedure in order to mimic closely CBCT datasets. We then considered the simulated CBCT images for training neural networks that predicted the noise and artifact-removed CT images. For this purpose, we employed a constrained generative adversarial neural network, which consisted of two deep neural networks, a generator and a discriminator. The generator produced the artifact-removed CT images while the discriminator computed the accuracy. The deformable image registration (DIR) results were finally validated using the model-generated landmarks. Results showed that the artifact-removed CT matched closely to the planning CT. Comparisons were performed using the image similarity metrics, and a normalized cross correlation of >0.95 was obtained from the cGAN based image enhancement. In addition, when DIR was performed, the landmarks matched within 1.1 +/- 0.5 mm. This demonstrates that using an adversarial DNN-based CBCT enhancement, improved DIR accuracy bolsters adaptive radiotherapy workflow.
引用
收藏
页数:10
相关论文
共 31 条
  • [21] A feature alignment score for online cone-beam CT-based image-guided radiotherapy for prostate cancer
    Hargrave, Catriona
    Deegan, Timothy
    Poulsen, Michael
    Bednarz, Tomasz
    Harden, Fiona
    Mengersen, Kerrie
    MEDICAL PHYSICS, 2018, 45 (07) : 2898 - 2911
  • [22] Accumulation of the delivered dose based on cone-beam CT and deformable image registration for non-small cell lung cancer treated with hypofractionated radiotherapy
    Wang, Bin
    Wang, Da Quan
    Lin, Mao Sheng
    Lu, Shi Pei
    Zhang, Jun
    Chen, Li
    Li, Qi Wen
    Cheng, Zhang Kai
    Liu, Fang Jie
    Guo, Jin Yu
    Liu, Hui
    Qiu, Bo
    BMC CANCER, 2020, 20 (01)
  • [23] Accumulation of the delivered dose based on cone-beam CT and deformable image registration for non-small cell lung cancer treated with hypofractionated radiotherapy
    Bin Wang
    Da Quan Wang
    Mao Sheng Lin
    Shi Pei Lu
    Jun Zhang
    Li Chen
    Qi Wen Li
    Zhang Kai Cheng
    Fang Jie Liu
    Jin Yu Guo
    Hui Liu
    Bo Qiu
    BMC Cancer, 20
  • [24] Deformable registration of the inflated and deflated lung in cone-beam CT-guided thoracic surgery: Initial investigation of a combined model- and image-driven approach
    Uneri, Ali
    Nithiananthan, Sajendra
    Schafer, Sebastian
    Otake, Yoshito
    Stayman, J. Webster
    Kleinszig, Gerhard
    Sussman, Marc S.
    Prince, Jerry L.
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2013, 40 (01)
  • [25] Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment
    Paluska, Petr
    Hanus, Josef
    Sefrova, Jana
    Rouskova, Lucie
    Grepl, Jakub
    Jansa, Jan
    Kasaova, Linda
    Hodek, Miroslav
    Zouhar, Milan
    Vosmik, Milan
    Petera, Jiri
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2012, 17 (03) : 134 - 140
  • [26] Analyses of the factors influencing the accuracy of three-dimensional ultrasound in comparison with cone-beam CT in image-guided radiotherapy for prostate cancer with or without pelvic lymph node irradiation
    Sha Zhou
    Liling Luo
    Jibin Li
    Maosheng Lin
    Li Chen
    Jianhui Shao
    Shipei Lu
    Yaru Ma
    Yingting Zhang
    Wenfen Chen
    Mengzhong Liu
    Shiliang Liu
    Liru He
    Radiation Oncology, 14
  • [27] Analyses of the factors influencing the accuracy of three-dimensional ultrasound in comparison with cone-beam CT in image-guided radiotherapy for prostate cancer with or without pelvic lymph node irradiation
    Zhou, Sha
    Luo, Liling
    Li, Jibin
    Lin, Maosheng
    Chen, Li
    Shao, Jianhui
    Lu, Shipei
    Ma, Yaru
    Zhang, Yingting
    Chen, Wenfen
    Liu, Mengzhong
    Liu, Shiliang
    He, Liru
    RADIATION ONCOLOGY, 2019, 14 (1)
  • [28] High-Accuracy 3D Image-Based Registration of Endoscopic Video to C-Arm Cone-Beam CT for Image-Guided Skull Base Surgery
    Mirota, Daniel J.
    Uneri, Ali
    Schafer, Sebastian
    Nithiananthan, Sajendra
    Reh, Douglas D.
    Gallia, Gary L.
    Taylor, Russell H.
    Hager, Gregory D.
    Siewerdsen, Jeffrey H.
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [29] Evaluation of a System for High-Accuracy 3D Image-Based Registration of Endoscopic Video to C-Arm Cone-Beam CT for Image-Guided Skull Base Surgery
    Mirota, Daniel J.
    Uneri, Ali
    Schafer, Sebastian
    Nithiananthan, Sajendra
    Reh, Douglas D.
    Ishii, Masaru
    Gallia, Gary L.
    Taylor, Russell H.
    Hager, Gregory D.
    Siewerdsen, Jeffrey H.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (07) : 1215 - 1226
  • [30] Image guided surgical navigation integrating "mirroring" computational planning based on intra-operative cone-beam CT imaging: A promising new approach for management of primary bilateral midfacial fractures
    Terzic, Andrej
    Scolozzi, Paolo
    COMPUTER AIDED SURGERY, 2011, 16 (04) : 170 - 180