An adversarial machine learning based approach and biomechanically-guided validation for improving deformable image registration accuracy between a planning CT and cone-beam CT for adaptive prostate radiotherapy applications

被引:1
|
作者
Santhanam, Anand P. [1 ]
Lauria, Michael [1 ]
Stiehl, Brad [1 ]
Elliott, Daniel [2 ]
Seshan, Saty [2 ]
Hsieh, Scott [1 ]
Cao, Minsong [1 ]
Low, Daniel [1 ]
机构
[1] Univ Calif Los Angeles, Dept Radiat Oncol, Los Angeles, CA 90024 USA
[2] SegAna LLC, Orlando, FL USA
来源
MEDICAL IMAGING 2020: IMAGE PROCESSING | 2021年 / 11313卷
基金
美国国家科学基金会;
关键词
HEAD;
D O I
10.1117/12.2550493
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Adaptive radiotherapy is an effective procedure for the treatment of cancer, where the daily anatomical changes in the patient are quantified, and the dose delivered to the tumor is adapted accordingly. Deformable Image Registration (DIR) inaccuracies and delays in retrieving and registering on-board cone beam CT (CBCT) image datasets from the treatment system with the planning kilo Voltage CT (kVCT) have limited the adaptive workflow to a limited number of patients. In this paper, we present an approach for improving the DIR accuracy using a machine learning approach coupled with biomechanically guided validation. For a given set of 11 planning prostate kVCT datasets and their segmented contours, we first assembled a biomechanical model to generate synthetic abdominal motions, bladder volume changes, and physiological regression. For each of the synthetic CT datasets, we then injected noise and artifacts in the images using a novel procedure in order to mimic closely CBCT datasets. We then considered the simulated CBCT images for training neural networks that predicted the noise and artifact-removed CT images. For this purpose, we employed a constrained generative adversarial neural network, which consisted of two deep neural networks, a generator and a discriminator. The generator produced the artifact-removed CT images while the discriminator computed the accuracy. The deformable image registration (DIR) results were finally validated using the model-generated landmarks. Results showed that the artifact-removed CT matched closely to the planning CT. Comparisons were performed using the image similarity metrics, and a normalized cross correlation of >0.95 was obtained from the cGAN based image enhancement. In addition, when DIR was performed, the landmarks matched within 1.1 +/- 0.5 mm. This demonstrates that using an adversarial DNN-based CBCT enhancement, improved DIR accuracy bolsters adaptive radiotherapy workflow.
引用
收藏
页数:10
相关论文
共 31 条
  • [1] On the Feasibility of On-Table Adaptive Prostate Radiotherapy Using An Adversarial and Biomechanically Guided Machine Learning Approach for Deformable Image Registration of Planning CT and Cone Beam CT
    Santhanam, A.
    Lauria, M.
    Stiehl, B.
    Elliott, D.
    Seshan, S.
    Hsieh, S.
    Kishan, A.
    Cao, M.
    Low, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E642 - E643
  • [2] Deformable image registration in cone-beam CT images for image-guided adaptive radiotherapy
    Zhang, L.
    Dong, L.
    Zhu, X.
    Garden, A.
    Ahamad, A.
    Ang, K.
    Mohan, R.
    MEDICAL PHYSICS, 2006, 33 (06) : 1995 - 1995
  • [3] Incorporating the synthetic CT image for improving the performance of deformable image registration between planning CT and cone-beam CT
    Li, Na
    Zhou, Xuanru
    Chen, Shupeng
    Dai, Jingjing
    Wang, Tangsheng
    Zhang, Chulong
    He, Wenfeng
    Xie, Yaoqin
    Liang, Xiaokun
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [4] Deformable image registration for cone-beam CT (CBCT) images for implemantion of image-guided adaptive radiotherapy
    Zhang, L.
    Dong, L.
    Ahamad, A.
    Zhu, X. R.
    Garden, A. S.
    Ang, K. K.
    Mohan, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S647 - S648
  • [5] Deformable image registration for contour propagation from CT to cone-beam CT scans in radiotherapy of prostate cancer
    Thor, Maria
    Petersen, Jorgen B. B.
    Bentzen, Lise
    Hoyer, Morten
    Muren, Ludvig Paul
    ACTA ONCOLOGICA, 2011, 50 (06) : 918 - 925
  • [6] Evaluation of deformable image registration for contour propagation between CT and cone-beam CT images in adaptive head and neck radiotherapy
    Li, X.
    Zhang, Y. Y.
    Shi, Y. H.
    Zhou, L. H.
    Zhen, X.
    TECHNOLOGY AND HEALTH CARE, 2016, 24 : S747 - S755
  • [7] Accuracy of radiotherapy dose calculations based on cone-beam CT: comparison of deformable registration and image correction based methods
    Marchant, T. E.
    Joshi, K. D.
    Moore, C. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (06):
  • [8] Evaluation of Deformable Image Registration-Based Contour Propagation From Planning CT to Cone-Beam CT
    Woerner, Andrew J.
    Choi, Mehee
    Harkenrider, Matthew M.
    Roeske, John C.
    Surucu, Murat
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (06) : 801 - 810
  • [9] Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy
    Wu, T. -H.
    Liang, C. -H.
    Wu, J. -K.
    Lien, C. -Y.
    Yang, B. -H.
    Huang, Y. -H.
    Lee, J. J. S.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [10] Deep learning based direct segmentation assisted by deformable image registration for cone-beam CT based auto-segmentation for adaptive radiotherapy
    Liang, Xiao
    Morgan, Howard
    Bai, Ti
    Dohopolski, Michael
    Nguyen, Dan
    Jiang, Steve
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (04):