Reference Values and Z Scores for Pulsed-Wave Doppler and M-Mode Measurements in Fetal Echocardiography

被引:34
|
作者
Gagnon, Catherine [1 ,2 ]
Bigras, Jean-Luc [3 ]
Fouron, Jean-Claude [3 ]
Dallaire, Frederic [1 ,2 ]
机构
[1] Univ Sherbrooke, Fac Med & Hlth Sci, Div Pediat Cardiol, Sherbrooke, PQ J1K 2R1, Canada
[2] Ctr Hosp Univ Sherbrooke, Ctr Rech, Sherbrooke, PQ, Canada
[3] Univ Montreal, Fac Med, Div Pediat Cardiol, St Justine Univ Hlth Ctr, Montreal, PQ H3C 3J7, Canada
关键词
Fetal echocardiography; Z score; Reference values; Fetal heart function; MYOCARDIAL PERFORMANCE INDEX; ISTHMUS BLOOD-FLOW; CROSS-SECTIONAL ECHOCARDIOGRAPHY; NORMAL REFERENCE RANGES; INFERIOR VENA-CAVA; AORTIC ISTHMUS; CARDIAC-OUTPUT; DUCTUS VENOSUS; AMERICAN SOCIETY; 3RD TRIMESTERS;
D O I
10.1016/j.echo.2016.01.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Fetal echocardiography is now the standard approach for detailed investigations of fetal cardiac anatomy and function. Available studies proposing reference values for pulsed-wave Doppler (PWD) measurements are often focused on few parameters. Furthermore, the methodology used for validating these proposed reference values is sometimes insufficiently described, and parameters necessary to compute Z scores are not always available. Improved definition of reference values with adequate statistical validation is needed for proper interpretation of PWD measurements in a clinical setting. In this study, the authors propose a comprehensive set of reference values and Z score equations for fetal PWD and M-mode measurements with thorough assessment of Z score quality and validity. Methods: Women with normal singleton pregnancies between 18 and 39 weeks of gestational age were included. A set of 57 measurements was performed, including PWD, M-mode measurements, and calculation of systolic, diastolic, and global function indices. Several parametric regressions were tested to model each measurement against gestational age. The SD was also modeled to account for heteroscedasticity. Z score equations were computed, and the proposed reference values were tested for residual association, residual heteroscedasticity, and departure from the normal distribution. Results: One hundred four uncomplicated singleton pregnancies with normal fetal hearts were included. Nonlinear relationships with gestational age were found for most measurements. Parametric normalization was successful for most measurements analyzed, and it was possible to compute Z score equations with minimal residual association with gestational age, no residual heteroscedasticity, and no significant departure from the normal distribution. Conclusions: The authors propose a comprehensive set of Z score equations for 57 fetal functional measurements, some of which do not have any published reference values. These Z score equations will allow echocardiographers to more accurately identify measurements that diverge from normal and thus detect earlier potential alterations in fetal heart function.
引用
收藏
页码:448 / +
页数:22
相关论文
共 39 条
  • [1] Pulsed-wave tissue Doppler echocardiography for the analysis of fetal cardiac arrhythmias
    Tutschek, B.
    Schmidt, K. G.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2011, 38 (04) : 406 - 412
  • [2] Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
    Hodges, Ryan
    Endo, Masayuki
    La Gerche, Andre
    Eixarch, Elisenda
    DeKoninck, Philip
    Ferferieva, Vessilina
    D'hooge, Jan
    Wallace, Euan M.
    Deprest, Jan
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2013, (76):
  • [3] Z-score reference ranges for pulsed-wave Doppler indices of the cardiac outflow tracts in normal fetuses
    Mao, Yan Kai
    Zhao, Bo Wen
    Zhou, Li
    Wang, Bei
    Chen, Ran
    Wang, Shan Shan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (05) : 811 - 825
  • [4] Z-score reference ranges for pulsed-wave Doppler indices of the cardiac outflow tracts in normal fetuses
    Yan Kai Mao
    Bo Wen Zhao
    Li Zhou
    Bei Wang
    Ran Chen
    Shan Shan Wang
    The International Journal of Cardiovascular Imaging, 2019, 35 : 811 - 825
  • [5] Reference Values and Repeatability of Pulsed Wave Doppler Echocardiography Parameters in Normal Donkeys
    Marzok, Mohamed
    Almubarak, Adel, I
    Al Mohamad, Zakriya
    Salem, Mohamed
    Farag, Alshimaa M.
    Ibrahim, Hussam M.
    El-Ashker, Maged R.
    El-khodery, Sabry
    ANIMALS, 2022, 12 (17):
  • [6] Normative change with gestation in fetal intraventricular pressure difference with color M-mode Doppler echocardiography
    Yamamoto, Yuka
    Takahashi, Ken
    Takamizu, Ai
    Ogawa, Takahisa
    Yoshida, Koyo
    Itakura, Atsuo
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2023, 49 (07) : 1743 - 1749
  • [7] Reference values and repeatability of pulsed-wave Doppler flowmetry of portal vein in healthy dromedary she-camels
    Elsayed, Ahmed A.
    Gomaa, Naglaa A.
    JOURNAL OF ADVANCED VETERINARY AND ANIMAL RESEARCH, 2020, 7 (04) : 698 - 703
  • [8] Cardiac Time Intervals By Tissue Doppler Imaging M-mode Echocardiography: Reproducibility, Reference Values, Association with Clinical Characteristics and Prognostic Implications
    Biering-Sorensen, Tor
    DANISH MEDICAL JOURNAL, 2016, 63 (08):
  • [9] Fetal cardiac filling and ejection time fractions by pulsed-wave Doppler: reference ranges and potential clinical application
    Soveral, I
    Crispi, F.
    Guirado, L.
    Garcia-Otero, L.
    Torres, X.
    Bennasar, M.
    Sepulveda-Martinez, A.
    Nogue, L.
    Gratacos, E.
    Martinez, J. M.
    Bijnens, B.
    Friedberg, M.
    Gomez, O.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2021, 58 (01) : 83 - 91
  • [10] Comparison of Reference Values and Z Scores of Pulse-Doppler Waveforms of Fetal Pulmonary Artery and Aorta
    Moghadam, Ehsan Aghaei
    Rad, Elaheh Malakan
    Majnoon, Mohammad-Taghi
    Nikoofar, Maryam
    Kocharian, Armen
    Zeinaloo, Ali Akbar
    IRANIAN JOURNAL OF PEDIATRICS, 2018, 28 (04)