Controlling dispersion of axonal regeneration using a multichannel collagen nerve conduit

被引:216
作者
Yao, Li [1 ,2 ]
de Ruiter, Godard C. W. [3 ,5 ]
Wang, Huan [3 ]
Knight, Andrew M. [2 ]
Spinner, Robert J. [3 ]
Yaszemski, Michael J. [4 ]
Windebank, Anthony J. [2 ]
Pandit, Abhay [1 ]
机构
[1] Natl Univ Ireland, Network Excellence Funct Biomat NFB, Natl Ctr Biomed Engn Sci, Galway, Ireland
[2] Mayo Clin, Dept Neurobiol, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Neurosurg, Rochester, MN 55905 USA
[4] Mayo Clin, Dept Orthopaed, Rochester, MN 55905 USA
[5] Leiden Univ, Dept Neurosurg, Med Ctr, NL-2300 RA Leiden, Netherlands
基金
爱尔兰科学基金会;
关键词
Collagen; Nerve regeneration; Nerve conduit; Neural tissue engineering; In vivo; RAT SCIATIC-NERVE; SCHWANN-CELLS; MOTOR AXONS; REPAIR; TUBES; IMMOBILIZATION; REINNERVATION; IMPLANTS; NEURONS; GRAFTS;
D O I
10.1016/j.biomaterials.2010.03.081
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Single channel conduits are used clinically in nerve repair as an alternative to the autologous nerve graft. Axons regenerating across single channel tubes, however, may disperse resulting in inappropriate target reinnervation. This dispersion may be limited by multichannel nerve conduits as they resemble the structure of nerve multiple basal lamina tubes. In this study, we investigated the influence of channel number on the axonal regeneration using a series of 1-, 2-, 4-, and 7-channel collagen conduits and commercial (NeuraGen (R)) single channel conduits. Nerve conduits were implanted in rats with a 1 cm gap of sciatic nerve. After four months, quantitative results of regeneration were evaluated with nerve morphometry and the accuracy of regeneration was assessed using retrograde tracing: two tracers being applied simultaneously to tibial and peroneal nerves to determine the percentage of motor neurons with double projections. Recovery of function was investigated with compound muscle action potential recordings and ankle motion analysis. We showed that the fabricated 1-channel and 4-channel conduits are superior to other types of conduits in axonal regeneration. Simultaneous tracing showed a significantly lower percentage of motor neurons with double projections after 2- and 4-channel compared with 1-channel conduit repair. This study shows the potential influence of multichannel guidance on limiting dispersion without decreasing quantitative results of regeneration. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5789 / 5797
页数:9
相关论文
共 38 条
[31]   Synthetic nerve guide implants in humans: A comprehensive survey [J].
Schlosshauer, Burkhard ;
Dreesmann, Lars ;
Schaller, Hans-Eberhard ;
Sinis, Nektarios .
NEUROSURGERY, 2006, 59 (04) :740-747
[32]   RELATIVE IMPORTANCE OF BASEMENT-MEMBRANE AND SOLUBLE GROWTH-FACTORS IN DELAYED AND IMMEDIATE REGENERATION OF RAT SCIATIC-NERVE [J].
SORENSON, EJ ;
WINDEBANK, AJ .
JOURNAL OF NEUROPATHOLOGY AND EXPERIMENTAL NEUROLOGY, 1993, 52 (03) :216-222
[33]   Evaluation of peripheral nerve regeneration across an 80-mm gap using a polyglycolic acid (PGA) - collagen nerve conduit filled with laminin-soaked collagen sponge in dogs [J].
Toba, T ;
Nakamura, T ;
Lynn, AK ;
Matsumoto, K ;
Fukuda, S ;
Yoshitani, M ;
Hori, Y ;
Shimizu, Y .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2002, 25 (03) :230-237
[34]   Electrophysiologic findings and grip strength after nerve injuries in the rat forelimb [J].
Wang, Huan ;
Sorenson, Eric J. ;
Spinner, Robert J. ;
Windebank, Anthony J. .
MUSCLE & NERVE, 2008, 38 (04) :1254-1265
[35]   Dog sciatic nerve regeneration across a 30-mm defect bridged by a chitosan/PGA artificial nerve graft [J].
Wang, XD ;
Hu, W ;
Cao, Y ;
Yao, J ;
Wu, J ;
Gu, XS .
BRAIN, 2005, 128 :1897-1910
[36]   Immobilization of heparin to EDC/NHS-crosslinked collagen. Characterization and in vitro evaluation [J].
Wissink, MJB ;
Beernink, R ;
Pieper, JS ;
Poot, AA ;
Engbers, GHM ;
Beugeling, T ;
van Aken, WG ;
Feijen, J .
BIOMATERIALS, 2001, 22 (02) :151-163
[37]   Pathway sampling by regenerating peripheral axons [J].
Witzel, C ;
Rohde, C ;
Brushart, TM .
JOURNAL OF COMPARATIVE NEUROLOGY, 2005, 485 (03) :183-190
[38]   Development and evaluation of silk fibroin-based nerve grafts used for peripheral nerve regeneration [J].
Yang, Yumin ;
Ding, Fel ;
Wu, Han ;
Hu, Wen ;
Liu, Wei ;
Liu, He ;
Gu, Xiaosong .
BIOMATERIALS, 2007, 28 (36) :5526-5535