Fatigue Testing of a New Locking Plate for Hip Fractures

被引:10
|
作者
Hunt, Stephen [1 ]
Martin, Rod [1 ]
Woolridge, Bryan [1 ]
机构
[1] Mem Univ Newfoundland, Dept Orthoped Surg, St John, NF A1C 5S7, Canada
关键词
Hip fracture; Fatigue; Femoral neck; Trauma; Biomechnical; Locking plate; FEMORAL-NECK FRACTURES; ORTHOPEDIC DEVICES; FIXATION; METAANALYSIS; FAILURE; SCREW;
D O I
10.5405/jmbe.826
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Femoral neck shortening and varus deformity can have a significant effect on functional outcomes in patients with femoral neck fractures, particularly in young trauma patients. This study proposes a locking plate construct to address femoral neck fractures. The biomechanical properties of the locking plate are investigated with a specific focus on fatigue performance. The challenges associated with the development of a standardized pre-clinical testing model are also discussed. The development of a testing strategy and three mechanical tests are described. Each of the testing phases compare the proposed plate construct against the currently accepted gold standard of three cancellous screws. The first phase of biomechanical testing involves cadaveric specimens, which are statically loaded until ultimate failure of the construct. The second phase cyclically loads instrumented synthetic bone substitute samples with hardware installed without compression at the fracture site. The third phase cyclically loads samples with hardware installed with compression at the fracture site. Static testing results indicate that the proposed locking plate construct can withstand significantly higher static loads before failure than can the three cancellous screw technique. Fatigue testing results show that without compression across the fracture site, the samples instrumented with the locking plate construct had a shorter fatigue life than samples instrumented with 3 cancellous screws. With compression across the fracture site, the fatigue performance of the proposed locking plate is equivalent to that of 3 cancellous screws. The results indicate that the proposed locking plate construct for hip fractures has superior static strength and equivalent fatigue life compared to those of 3 cancellous screws. Biomechanical testing results show that compression across the fracture site is critical to the fatigue performance of both constructs. The development of a preclinical testing strategy for trauma products requires an understanding of the intended application of the product, expected modes of failure, and a thorough understanding of the product's service requirements.
引用
收藏
页码:117 / 122
页数:6
相关论文
共 50 条
  • [31] Complications of the locking plate for displaced proximal humeral fractures
    Lu Yi
    Wang Man-yi
    Zhu Yi-ming
    Jiang Chun-yan
    CHINESE MEDICAL JOURNAL, 2010, 123 (19) : 2671 - 2675
  • [32] A Specialized Fibular Locking Plate for Lateral Malleolar Fractures
    Yeo, Eui Dong
    Kim, Hak Jun
    Cho, Woo In
    Lee, Young Koo
    Journal of Foot & Ankle Surgery, 2015, 54 (06) : 1067 - 1071
  • [33] Complications Associated with Locking Plate of Proximal Humerus Fractures
    Kavuri, Venkat
    Bowden, Blake
    Kumar, Neil
    Cerynik, Doug
    INDIAN JOURNAL OF ORTHOPAEDICS, 2018, 52 (02) : 108 - 116
  • [34] Evaluation of the Results of Minimally invasive Plate Osteosynthesis Using a Locking Plate in the Treatment of Distal Femur Fractures
    Abdelmonem, Abdelmonem H.
    Saber, Ahmed Y.
    El Sagheir, Mohamed
    El-Malky, Awad
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [35] Treatment of comminuted proximal humeral fractures using locking plate with strut allograft
    Cha, Hongeun
    Park, Ki-Beom
    Oh, Seungbae
    Jeong, Jinyoung
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (05) : 781 - 785
  • [36] Intraarticular Distal End Radius Fractures Treated with Volar Locking Plate Variations
    Gaonkar, Nishant
    Patil, Nitin
    Kolekar, Anupam
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S1030 - S1032
  • [37] Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures
    Oh, Chang-Wug
    Kim, Jung-Jae
    Byun, Young-Soo
    Oh, Jong-Keon
    Kim, Joon-Woo
    Kim, Shin-Yoon
    Park, Byung-Chul
    Lee, Hyun-Joo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (12) : 1659 - 1665
  • [38] Mechanical Failure After Locking Plate Fixation of Unstable Intertrochanteric Femur Fractures
    Streubel, Philipp N.
    Moustoukas, Michael J.
    Obremskey, William T.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (01) : 22 - 28
  • [39] Application of distal femoral 90° locking plate in children with supracondylar femoral fractures
    Zhang, Y. -J.
    Wang, Y. -J.
    Wang, S. -H.
    Song, X. -L.
    Zhao, N.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (17) : 7956 - 7967
  • [40] Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures
    Chang-Wug Oh
    Jung-Jae Kim
    Young-Soo Byun
    Jong-Keon Oh
    Joon-Woo Kim
    Shin-Yoon Kim
    Byung-Chul Park
    Hyun-Joo Lee
    Archives of Orthopaedic and Trauma Surgery, 2009, 129 : 1659 - 1665