Low Cost Electrodes Cell in Capacitively Coupled Contactless Conductivity Detector for Microfluidic Chemical Analysis

被引:0
作者
Cao, X. [1 ]
Wang, Y. [1 ]
Hogan, A. [1 ]
Vazquez, P. [1 ]
Messina, W. [1 ]
Moore, E. [1 ]
机构
[1] Univ Coll Cork, Sch Chem, Sensing & Separat Grp, Tyndall Natl Inst,Life Sci Interface Grp, Cork, Ireland
来源
2018 IEEE 18TH INTERNATIONAL CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO) | 2018年
关键词
CAPILLARY-ELECTROPHORESIS; MICROCHIP;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this paper, a low cost electrodes cell for capacitively coupled contactless conductivity detector (C4D) is studied. The electrodes cells were fabricated by printed circus board (PCB) photolithography, and coupled with polydimethylsiloxane (PDMS) microchips. Potassium (K+) and sodium (Na+) were separated and detected in this system. Experiments were carried out based on different parameters and designs. Parameters including frequency (75, 150, and 300 kHz), voltage (-12 and -6 dB of full output voltage), gain (50%, 75% and 100%), ADC (16.66, 19.80 and 34.15 Hz), and filter (medium, fast and off) were set up on the detector before each run. Electrodes width was tested using PCB electrodes cells with 0.7 and 1 mm widths. Microchip channel length was tested with 35 and 40 mm channels. These lengths were achieved by moving the microchip on top of the electrodes cell. Microchip channel width was tested using microchips with 100, 75 and 50 mu m width channels. The electrodes cells performed very robust detection ability, with flat and stable baseline, and satisfied signal-to-noise ratio (SNR).
引用
收藏
页数:4
相关论文
共 50 条
[41]   A facile online multi-gear capacitively coupled contactless conductivity detector for an automatic and wide range monitoring of high salt in HPLC [J].
Liu, Weiwen ;
Liang, Ziqi ;
Wang, Yuanyu ;
Cao, Jun ;
Zhang, Qiang ;
Liu, Xiaoping ;
Wang, Yuxing ;
Cao, Chengxi .
ANALYST, 2022, 147 (03) :496-504
[42]   Application of capillary electrophoresis with capacitively contactless conductivity detection for biomedical analysis [J].
Elbashir, Abdalla A. ;
Osman, Abdelbagi ;
Elawad, Mohammed ;
Ziyada, Abobakr K. ;
Aboul-Enein, Hassan Y. .
ELECTROPHORESIS, 2024, 45 (5-6) :400-410
[43]   Development and Validation of a CE Method for the Determination of Tetracyclines with Capacitively Coupled Contactless Conductivity Detection [J].
Prasanta Paul ;
Josephine Reynaert ;
Cari Sänger-van de Griend ;
Erwin Adams ;
Ann Van Schepdael .
Chromatographia, 2019, 82 :1395-1403
[44]   Determination of carbethopendecinium bromide in eye drops by capillary electrophoresis with capacitively coupled contactless conductivity detection [J].
Petru, Klara ;
Jac, Pavel ;
Sindelkova, Martina ;
Polasek, Miroslav .
JOURNAL OF SEPARATION SCIENCE, 2011, 34 (10) :1174-1179
[45]   Determination of Biogenic Amines in Seawater Using Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection [J].
Gubartallah, Elbaleeq A. ;
Makahleh, Ahmad ;
Quirino, Joselito P. ;
Saad, Bahruddin .
MOLECULES, 2018, 23 (05)
[46]   20th anniversary of axial capacitively coupled contactless conductivity detection in capillary electrophoresis [J].
Kuban, Pavel ;
Hauser, Peter C. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 102 :311-321
[47]   Rapid determination of meldonium in urine samples by capillary electrophoresis with capacitively coupled contactless conductivity detection [J].
Sampova, Andrea ;
Kuban, Pavel .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1468 :236-240
[48]   A Highly Portable Smartphone-Based Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection [J].
Tao, Zhimin ;
Zhang, Qiang ;
Cao, Yiren ;
Duan, Xunjie ;
Wu, Yuyang ;
Fan, Liuyin ;
Cao, Chengxi ;
Liu, Weiwen .
SENSORS, 2025, 25 (07)
[49]   A handheld contactless conductivity detector for monitoring the desalting of low-volume virus and cell samples [J].
Cao, Yiren ;
Tao, Zhimin ;
Tian, Youli ;
Chen, Ke-Er ;
Zhang, Lu ;
Ren, Jicun ;
Xiao, Hua ;
Zhang, Qiang ;
Liu, Weiwen ;
Cao, Chengxi .
BIOSENSORS & BIOELECTRONICS, 2023, 237
[50]   A simple, low-cost and robust capillary zone electrophoresismethod with capacitively coupled contactless conductivity detection for the routine determination of four selected penicillins in money-constrained laboratories [J].
Paul, Prasanta ;
Sanger-van de Griend, Cari ;
Adams, Erwin ;
Van Schepdael, Ann .
ELECTROPHORESIS, 2018, 39 (20) :2521-2529