Clinical Validation of a Real-Time Data Processing System for Cardiac Output and Arterial Pressure Measurement During Intraoperative Biventricular Pacing Optimization

被引:2
作者
Johnson, Christopher K. [1 ]
Cabreriza, Santos E. [1 ]
Sahar, Rana L. [1 ]
Rusanov, Alexander [1 ]
Wang, Daniel Y. [2 ]
Cheng, Bin [3 ]
Gendy, Mira S. [1 ]
Quinn, T. Alexander [4 ]
Spotnitz, Henry Michael [1 ]
机构
[1] Columbia Univ, Dept Surg, New York, NY USA
[2] Columbia Univ, Dept Med, New York, NY USA
[3] Mailman Sch Publ Hlth, Dept Biostat, New York, NY USA
[4] Univ London Imperial Coll Sci Technol & Med, Cardiac Biophys & Syst Biol Grp, Natl Heart & Lung Inst, London, England
关键词
RESYNCHRONIZATION THERAPY; HEART-FAILURE; ECHOCARDIOGRAPHY; IMPLANTATION; PREDICTORS; DEVICE; DELAY;
D O I
10.1097/MAT.0b013e31824aefce
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Biventricular pacing (BiVP) improves cardiac output (CO) and mean arterial pressure (MAP) after cardiopulmonary bypass (CPB) in selected patients at risk for acute left heart failure after cardiac surgery. Optimization of atrioventricular delay (AVD) and interventricular delay (VVD) to maximize the hemodynamic effect of pacing requires rapid and accurate data processing. Conventional post hoc data processing (PP) is accurate but time-consuming, and infeasible in the intraoperative setting. We created a customized, real-time data processing (RTP) system to improve data processing efficiency, while maintaining accuracy. Biventricular pacing optimization was performed within 1 hour of the conclusion of CPB in 10 patients enrolled in the Biventricular Pacing After Cardiac Surgery trial. Cardiac output, measured by an electromagnetic flow meter, and arterial pressure were recorded as AVD was randomly varied across seven settings and VVD across nine settings. Post hoc data processing values calculated by two observers were compared to RTP-generated outputs for CO and MAP. Interexaminer reliability coefficients were generated to access the dependability of RTP. Interexaminer reliability coefficient values ranged from 0.997 to 0.999, indicating RTP is as reliable as PP for optimization. Real-time data processing is instantaneous and therefore is more practical in a clinical setting than the PP method. Real-time data processing is useful for guiding intraoperative BiVP optimization and merits further development. ASAIO Journal 2012; 58:191-196.
引用
收藏
页码:191 / 196
页数:6
相关论文
共 32 条
  • [1] Cardiac resynchronization in chronic heart failure
    Abraham, WT
    Fisher, WG
    Smith, AL
    Delurgio, DB
    Leon, AR
    Loh, E
    Kocovic, DZ
    Packer, M
    Clavell, AL
    Hayes, DL
    Ellestad, M
    Messenger, J
    Trupp, RJ
    Underwood, J
    Pickering, F
    Truex, C
    McAtee, P
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) : 1845 - 1853
  • [2] Auricchio A, 1999, AM J CARDIOL, V83, p130D
  • [3] Echocardiography and Noninvasive Imaging in Cardiac Resynchronization Therapy Results of the PROSPECT (Predictors of Response to Cardiac Resynchronization Therapy) Study in Perspective
    Bax, Jeroen J.
    Gorcsan, John, III
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (21) : 1933 - 1943
  • [4] Optimized biventricular pacing in atrioventricular block after cardiac surgery
    Berberian, G
    Quinn, TA
    Kanter, JP
    Curtis, LJ
    Cabreriza, SE
    Weinberg, AD
    Spotnitz, HM
    [J]. ANNALS OF THORACIC SURGERY, 2005, 80 (03) : 870 - 875
  • [5] Validation study of PulseCO system for continuous cardiac output measurement
    Berberian, G
    Quinn, TA
    Vigilance, DW
    Park, DY
    Cabreriza, SE
    Curtis, LJ
    Spotnitz, HM
    [J]. ASAIO JOURNAL, 2005, 51 (01) : 37 - 40
  • [6] Interventricular Delay Interval Optimization in Cardiac Resynchronization Therapy Guided by Echocardiography Versus Guided by Electrocardiographic QRS Interval Width
    Bertini, Matteo
    Ziacchi, Matteo
    Biffi, Mauro
    Martignani, Cristian
    Saporito, Davide
    Valzania, Cinzia
    Diemberger, Igor
    Cervi, Elena
    Frisoni, Jessica
    Sangiorgi, Diego
    Branzi, Angelo
    Boriani, Giuseppe
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (10) : 1373 - 1377
  • [7] Can optimization of pacing settings compensate for a non-optimal left ventricular pacing site?
    Bogaard, Margot D.
    Doevendans, Pieter A.
    Leenders, Geert E.
    Loh, Peter
    Hauer, Richard N. W.
    van Wessel, Harry
    Meine, Mathias
    [J]. EUROPACE, 2010, 12 (09): : 1262 - 1269
  • [8] Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure
    Bristow, MR
    Saxon, LA
    Boehmer, J
    Krueger, S
    Kass, DA
    De Marco, T
    Carson, P
    DiCarlo, L
    DeMets, D
    White, BG
    DeVries, DW
    Feldman, AM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) : 2140 - 2150
  • [9] Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay.
    Cazeau, S
    Leclercq, C
    Lavergne, T
    Walker, S
    Varma, C
    Linde, C
    Garrigue, S
    Kappenberger, L
    Haywood, GA
    Santini, M
    Bailleul, C
    Daubert, JC
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (12) : 873 - 880
  • [10] Results of the predictors of response to CRT (PROSPECT) trial
    Chung, Eugene S.
    Leon, Angel R.
    Tavazzi, Luigi
    Sun, Jing-Ping
    Nihoyannopoulos, Petros
    Merlino, John
    Abraham, William T.
    Ghio, Stefano
    Leclercq, Christophe
    Bax, Jeroen J.
    Yu, Cheuk-Man
    Gorcsan, John, III
    Sutton, Martin St John
    De Sutter, Johan
    Murillo, Jaime
    [J]. CIRCULATION, 2008, 117 (20) : 2608 - 2616