Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera

被引:118
|
作者
Duvall, W. Lane [1 ]
Croft, Lori B. [1 ]
Ginsberg, Eric S. [2 ]
Einstein, Andrew J. [3 ,4 ]
Guma, Krista A. [1 ]
George, Titus [1 ]
Henzlova, Milena J. [1 ]
机构
[1] Mt Sinai Med Ctr, Mt Sinai Div Cardiol Mt Sinai Heart, New York, NY 10029 USA
[2] Mt Sinai Med Ctr, Mt Sinai Dept Med, New York, NY 10029 USA
[3] Columbia Univ, Dept Med, Med Ctr, Div Cardiol, New York, NY USA
[4] Columbia Univ, Dept Radiol, Med Ctr, New York, NY USA
关键词
Myocardial perfusion imaging: SPECT; radiopharmaceuticals; diagnostic and prognostic application; image quality; MYOCARDIAL-PERFUSION; HIGH-SPEED; COMPUTED-TOMOGRAPHY; RADIATION; CARDIOLOGY; HEART;
D O I
10.1007/s12350-011-9379-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. In light of recent focus on diagnostic imaging, cardiac SPECT imaging needs to become a shorter test with lower radiation exposure to patients. Recently introduced Cadmium Zinc Telluride (CZT) cameras have the potential to achieve both goals. Methods. During a 2-month period patients presenting for a Tc-99m sestamibi SPECT MPI study were imaged using a CZT camera using a low-dose rest-stress protocol (5 mCi rest and 15 mCi stress doses). Patients >= 250 lbs or a BMI >= 35 kg/m(2) were excluded. Rest images were processed at 5- and 8-minute acquisition times and stress images at 3- and 5-minute acquisition times. A subset of patients had stress imaging performed using both conventional and CZT SPECT cameras. Image acquisition times and SPECT camera images were compared based on total counts, count rate, image quality, and summed rest and stress scores. Twelve month clinical follow-up was also obtained. Results. 131 patients underwent the study protocol (age 64.9 +/- 9.8 years, 54.2% male). There was no significant difference in image quality and mean summed scores between 5- and 8-minute rest images and between 3- and 5-minute stress images. When compared to a conventional SPECT camera in 27 patients, total rest and stress perfusion deficits and calculated LVEF were similar (r = 0.94 and 0.96, respectively). At 12 months there was a benign prognosis in patients with normal perfusion. The effective dose was 5.8 mSv for this protocol which is 49.2% less than conventional Tc-99m studies and 75.7% less than conventional Tl-201/Tc-99m dual isotope studies. Conclusions. New SPECT camera technology with low isotope dose significantly reduces ionizing radiation exposure and imaging times compared to traditional protocols while maintaining image quality and diagnostic accuracy. (J Nucl Cardiol 2011;18:847-57.)
引用
收藏
页码:847 / 857
页数:11
相关论文
共 34 条
  • [31] Quantitative high-efficiency cadmium-zinc-telluride SPECT with dedicated parallel-hole collimation system in obese patients: Results of a multi-center study
    Nakazato, Ryo
    Slomka, Piotr J.
    Fish, Mathews
    Schwartz, Ronald G.
    Hayes, Sean W.
    Thomson, Louise E. J.
    Friedman, John D.
    Lemley, Mark, Jr.
    Mackin, Maria L.
    Peterson, Benjamin
    Schwartz, Arielle M.
    Doran, Jesse A.
    Germano, Guido
    Berman, Daniel S.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (02) : 266 - 278
  • [32] High-efficiency X-ray luminescence in Eu3+-activated tungstate nanoprobes for optical imaging through energy transfer sensitization
    Guo, Tao
    Lin, Yan
    Zhang, Wei-Jian
    Hong, Jin-Sheng
    Lin, Ru-Hui
    Wu, Xiao-Ping
    Li, Juan
    Lu, Chun-Hua
    Yang, Huang-Hao
    NANOSCALE, 2018, 10 (04) : 1607 - 1612
  • [33] High-efficiency 3D black-blood thoracic aorta imaging with patch-based low-rank tensor reconstruction
    Shi, Caiyun
    Liu, Yuanyuan
    Cheng, Guanxu
    Qi, Yulong
    Wang, Haifeng
    Liu, Xin
    Liang, Dong
    Zhu, Yanjie
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (04) : 2538 - +
  • [34] A simulation study of ionizing radiation acoustic imaging (iRAI) as a real-time dosimetric technique for ultra-high dose rate radiotherapy (UHDR-RT)
    Sunbul, Noora H. Ba
    Zhang, Wei
    Oraiqat, Ibrahim
    Litzenberg, Dale W.
    Lam, Kwok L.
    Cuneo, Kyle
    Moran-Ebm, Jean M.
    Carson, Paul L.
    Wang, Xueding
    Clarke, Shaun D.
    Matuszak, Martha M.
    Pozzi, Sara A.
    El Naqa-EBM, Issam
    MEDICAL PHYSICS, 2021, 48 (10) : 6137 - 6151