Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera

被引:118
|
作者
Duvall, W. Lane [1 ]
Croft, Lori B. [1 ]
Ginsberg, Eric S. [2 ]
Einstein, Andrew J. [3 ,4 ]
Guma, Krista A. [1 ]
George, Titus [1 ]
Henzlova, Milena J. [1 ]
机构
[1] Mt Sinai Med Ctr, Mt Sinai Div Cardiol Mt Sinai Heart, New York, NY 10029 USA
[2] Mt Sinai Med Ctr, Mt Sinai Dept Med, New York, NY 10029 USA
[3] Columbia Univ, Dept Med, Med Ctr, Div Cardiol, New York, NY USA
[4] Columbia Univ, Dept Radiol, Med Ctr, New York, NY USA
关键词
Myocardial perfusion imaging: SPECT; radiopharmaceuticals; diagnostic and prognostic application; image quality; MYOCARDIAL-PERFUSION; HIGH-SPEED; COMPUTED-TOMOGRAPHY; RADIATION; CARDIOLOGY; HEART;
D O I
10.1007/s12350-011-9379-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. In light of recent focus on diagnostic imaging, cardiac SPECT imaging needs to become a shorter test with lower radiation exposure to patients. Recently introduced Cadmium Zinc Telluride (CZT) cameras have the potential to achieve both goals. Methods. During a 2-month period patients presenting for a Tc-99m sestamibi SPECT MPI study were imaged using a CZT camera using a low-dose rest-stress protocol (5 mCi rest and 15 mCi stress doses). Patients >= 250 lbs or a BMI >= 35 kg/m(2) were excluded. Rest images were processed at 5- and 8-minute acquisition times and stress images at 3- and 5-minute acquisition times. A subset of patients had stress imaging performed using both conventional and CZT SPECT cameras. Image acquisition times and SPECT camera images were compared based on total counts, count rate, image quality, and summed rest and stress scores. Twelve month clinical follow-up was also obtained. Results. 131 patients underwent the study protocol (age 64.9 +/- 9.8 years, 54.2% male). There was no significant difference in image quality and mean summed scores between 5- and 8-minute rest images and between 3- and 5-minute stress images. When compared to a conventional SPECT camera in 27 patients, total rest and stress perfusion deficits and calculated LVEF were similar (r = 0.94 and 0.96, respectively). At 12 months there was a benign prognosis in patients with normal perfusion. The effective dose was 5.8 mSv for this protocol which is 49.2% less than conventional Tc-99m studies and 75.7% less than conventional Tl-201/Tc-99m dual isotope studies. Conclusions. New SPECT camera technology with low isotope dose significantly reduces ionizing radiation exposure and imaging times compared to traditional protocols while maintaining image quality and diagnostic accuracy. (J Nucl Cardiol 2011;18:847-57.)
引用
收藏
页码:847 / 857
页数:11
相关论文
共 34 条
  • [1] Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera
    W. Lane Duvall
    Lori B. Croft
    Eric S. Ginsberg
    Andrew J. Einstein
    Krista A. Guma
    Titus George
    Milena J. Henzlova
    Journal of Nuclear Cardiology, 2011, 18 : 847 - 857
  • [2] Reduced isotope dose with rapid SPECT MPI imaging: Initial experience with a CZT SPECT camera
    Duvall, W. Lane
    Croft, Lori B.
    Godiwala, Tapan
    Ginsberg, Eric
    George, Titus
    Henzlova, Milena J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (06) : 1009 - 1014
  • [3] Reduced isotope dose with rapid SPECT MPI imaging: Initial experience with a CZT SPECT camera
    W. Lane Duvall
    Lori B. Croft
    Tapan Godiwala
    Eric Ginsberg
    Titus George
    Milena J. Henzlova
    Journal of Nuclear Cardiology, 2010, 17 : 1009 - 1014
  • [4] Comparison of high efficiency CZT SPECT MPI to coronary angiography
    Duvall, W. Lane
    Sweeny, Joseph M.
    Croft, Lori B.
    Barghash, Maya H.
    Kulkarni, Nitin K.
    Guma, Krista A.
    Henzlova, Milena J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (04) : 595 - 604
  • [5] Comparison of high efficiency CZT SPECT MPI to coronary angiography
    W. Lane Duvall
    Joseph M. Sweeny
    Lori B. Croft
    Maya H. Barghash
    Nitin K. Kulkarni
    Krista A. Guma
    Milena J. Henzlova
    Journal of Nuclear Cardiology, 2011, 18 : 595 - 604
  • [6] Reduced stress dose with rapid acquisition CZT SPECT MPI in a non-obese clinical population: Comparison to coronary angiography
    Duvall, W. Lane
    Sweeny, Joseph M.
    Croft, Lori B.
    Ginsberg, Eric
    Guma, Krista A.
    Henzlova, Milena J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (01) : 19 - 27
  • [7] Impact of a new ultrafast CZT SPECT camera for myocardial perfusion imaging: fewer equivocal results and lower radiation dose
    Mouden, Mohamed
    Timmer, Jorik R.
    Ottervanger, Jan Paul
    Reiffers, Stoffer
    Oostdijk, Ad H. J.
    Knollema, Siert
    Jager, Pieter L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 (06) : 1048 - 1055
  • [8] Radiation Dose and Prognosis of Ultra-Low-Dose Stress-First Myocardial Perfusion SPECT in Patients with Chest Pain Using a High-Efficiency Camera
    Einstein, Andrew J.
    Johnson, Lynne L.
    DeLuca, Albert J.
    Kontak, Andrew C.
    Groves, Daniel W.
    Stant, Jennifer
    Pozniakoff, Ted
    Cheng, Bin
    Rabbani, Leroy E.
    Bokhari, Sabahat
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (04) : 545 - 551
  • [9] Reduced administered activity, reduced acquisition time, and preserved image quality for the new CZT camera
    Jenny Oddstig
    Fredrik Hedeer
    Jonas Jögi
    Marcus Carlsson
    Cecilia Hindorf
    Henrik Engblom
    Journal of Nuclear Cardiology, 2013, 20 : 38 - 44
  • [10] Reduced administered activity, reduced acquisition time, and preserved image quality for the new CZT camera
    Oddstig, Jenny
    Hedeer, Fredrik
    Jogi, Jonas
    Carlsson, Marcus
    Hindorf, Cecilia
    Engblom, Henrik
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (01) : 38 - 44