Comparison of three rapid non-destructive techniques coupled with a classifier to increase transparency in the seafood value chain: Bioelectrical impedance analysis (BIA), near-infrared spectroscopy (NIR) and time domain reflectometry (TDR)

被引:4
作者
Melado-Herreros, Angela [1 ]
Nieto-Ortega, Sonia [1 ]
Olabarrieta, Idoia [1 ]
Ramilo-Fernandez, Graciela [2 ]
Sotelo, Carmen G. [2 ]
Teixeira, Barbara [3 ,4 ]
Velasco, Amaya [2 ]
Mendes, Rogerio [3 ,4 ]
机构
[1] AZTI, Food Res, Basque Res & Technol Alliance BRTA, Parque Tecnol Bizkaia,Edificio 609, Derio 48160, Bizkaia, Spain
[2] Inst Invest Marinas CSIC, Eduardo Cabello 6, Vigo 36208, Spain
[3] Portuguese Inst Sea & Atmosphere IPMA, Dept Sea & Marine Resources, Ave Doutor Alfredo Magalhaes Ramalho 6, P-1495165 Alges, Portugal
[4] Univ Porto, Interdisciplinary Ctr Marine & Environm Res CIIMA, Rua Bragas 289, P-4050123 Porto, Portugal
关键词
Traceability; Chemometrics; Fish chain; Added water; Smart sensors; FOOD-SUPPLY CHAINS; FROZEN-THAWED FISH; ABUSIVE WATER ADDITION; PROXIMATE COMPOSITION; FRESH; DIFFERENTIATION; QUALITY; MUSCLE; OCTOPUS; PROTEIN;
D O I
10.1016/j.jfoodeng.2022.110979
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Bioelectrical impedance analysis (BIA), near-infrared (NIR) spectroscopy and time domain reflectometry (TDR) were compared as non-destructive techniques, coupled with a classifier based on partial least square discriminant analysis (PLS-DA), to assess added water detection in a seafood model: tuna. Three classification models were developed for each technology in unfrozen, thawed and in a combination of both stages to distinguish between added and non-added water samples. Results were acceptable for the unfrozen stage with all the technologies, giving TDR the best performance (accuracy = 0.95; error rate = 0.06). However, results on the model for thawed stage were not satisfactory, due to the behavior of water during the freezing-thawing process in both types of samples (with and without added water). For the combined model, NIR failed in the classification (accuracy = 0.68; error rate = 0.32), BIA gave acceptable results (accuracy = 0.72; error rate = 0.28) and TDR made a good classification (accuracy = 0.87; error rate = 0.12).
引用
收藏
页数:10
相关论文
共 50 条
[31]   Rapid Differentiation of Unfrozen and Frozen-Thawed Tuna with Non-Destructive Methods and Classification Models: Bioelectrical Impedance Analysis (BIA), Near-Infrared Spectroscopy (NIR) and Time Domain Reflectometry (TDR) [J].
Nieto-Ortega, Sonia ;
Melado-Herreros, Angela ;
Foti, Giuseppe ;
Olabarrieta, Idoia ;
Ramilo-Fernandez, Graciela ;
Gonzalez Sotelo, Carmen ;
Teixeira, Barbara ;
Velasco, Amaya ;
Mendes, Rogerio .
FOODS, 2022, 11 (01)
[32]  
Oceana Canada, 2018, OC CAN REP UNC WID S
[33]   Food waste within food supply chains: quantification and potential for change to 2050 [J].
Parfitt, Julian ;
Barthel, Mark ;
Macnaughton, Sarah .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 2010, 365 (1554) :3065-3081
[34]  
Peng S., 2013, Journal of Food and Nutrition Research, V1, P42, DOI [10.12691/JFNR-1-4-2, DOI 10.12691/JFNR-1-4-2]
[35]   Fatty acid and proximate composition of bluefin tuna (Thunnus thynnus) muscle with regard to plasma lipids [J].
Popovic, Natalija Topic ;
Kozacinski, Lidija ;
Strunjak-Perovic, Ivancica ;
Coz-Rakovac, Rozelindra ;
Jadan, Margita ;
Cvrtila-Fleck, Zeljka ;
Barisic, Josip .
AQUACULTURE RESEARCH, 2012, 43 (05) :722-729
[36]   Detection of fish fillet substitution and mislabeling using multimode hyperspectral imaging techniques [J].
Qin, Jianwei ;
Vasefi, Fartash ;
Hellberg, Rosalee S. ;
Akhbardeh, Alireza ;
Isaacs, Rachel B. ;
Yilmaz, Ayse Gamze ;
Hwang, Chansong ;
Baek, Insuck ;
Schmidt, Walter F. ;
Kim, Moon S. .
FOOD CONTROL, 2020, 114
[37]   Non-invasive differentiation between fresh and frozen/thawed tuna fillets using near infrared spectroscopy (Vis-NIRS) [J].
Reis, M. M. ;
Martinez, E. ;
Saitua, E. ;
Rodriguez, R. ;
Perez, I. ;
Olabarrieta, I. .
LWT-FOOD SCIENCE AND TECHNOLOGY, 2017, 78 :129-137
[38]   Optimization of a nitrogen analyser based on the Dumas method [J].
Saint-Denis, T ;
Goupy, J .
ANALYTICA CHIMICA ACTA, 2004, 515 (01) :191-198
[39]  
Schimmer O., 2009, P 8 INT C EL WAV INT, P350
[40]  
Schimmer O, 2003, P 5 INT C EL WAV INT, P171