Out-of-plane strengthening of masonry walls with reinforced composites

被引:89
作者
Hamoush, SA [1 ]
McGinley, MW
Mlakar, P
Scott, D
Murray, K
机构
[1] N Carolina Agr & Tech State Univ, Arch Engn Dept, Greensboro, NC 27411 USA
[2] USA, Constr & Mat Div, Waterways Expt Stn, Vicksburg, MS 39180 USA
[3] N Carolina Agr & Tech State Univ, Dept Civil Engn, Greensboro, NC 27411 USA
关键词
D O I
10.1061/(ASCE)1090-0268(2001)5:3(139)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an investigation into the effectiveness of using fiber-reinforced composite overlays to strengthen existing unreinforced masonry walls to resist out-of-plane static loads. A total of fifteen wall panels [1,200 x 1,800 x 200 mm, (4 ft x 6 ft x 8 in.)] were tested. Twelve panels were assembled with fiber-reinforcing systems attached to the tension side, and the remaining three control walls were left without any external reinforcement. Two configurations of external reinforcement were evaluated. The first reinforcement configuration consisted of two layers of fiber-reinforced plastic webbing and the second consisted of vertical and horizontal bands of undirectional fiber composites. The three wall specimens without external reinforcement were tested to evaluate the change in the system strength and behavior with application of the external reinforcing systems. In addition to the two fiber configurations, the testing program also evaluated two methods of surface preparation of the walls, sand blasting, and wire brush. All specimens were thoroughly washed by water jet, 48 hours prior to application of the fiber-reinforcing systems. Three specimens were tested for each variable. A uniformly distributed lateral load was applied to each panel using the procedures described in the ASTM Standard E-72 Test Method (airbag). Failure loads, strains in the external reinforcement (FRP), out-of-plane deformations, and failure modes were recorded. Recommendations on the usefulness of the proposed technique as a means of strengthening masonry walls for out-of-plane loads are presented. In general, flexural strength of masonry walls can be increased if the shear failure is controlled.
引用
收藏
页码:139 / 145
页数:7
相关论文
共 10 条
[1]  
ALSHAAR G, 1998, 9886 USACERL US ARM
[2]  
[Anonymous], 1995, ANN BOOK ASTM STAND, DOI DOI 10.1520/2002C
[3]  
Ehsani M.R., 1997, J. Compos. Constr, V1, P17, DOI [10.1061/(ASCE)1090-0268(1997)1:1(17), DOI 10.1061/(ASCE)1090-0268(1997)1:1(17)]
[4]   FIBER COMPOSITE PLATES FOR STRENGTHENING BRIDGE BEAMS [J].
EHSANI, MR ;
SAADATMANESH, H .
COMPOSITE STRUCTURES, 1990, 15 (04) :343-355
[5]  
EHSANI MR, 1993, P ACI INT S NONM CON, P497
[6]  
Kolsch H., 1998, J. Compos. Constr, V2, P105, DOI [10.1061/(ASCE)1090-0268(1998)2:2(105), DOI 10.1061/(ASCE)1090-0268(1998)2:2(105)]
[7]  
MEIER U, 1992, P 1 INT C ADV COMP M, P243
[8]  
REINHORN AM, 1995, EVALUATION TYFO W FI
[9]  
REINHORN AM, 1995, 950001 AMR STAT U NE
[10]  
Triantafillou T. C., J COMPOS CONSTR, V2, P96, DOI DOI 10.1061/(ASCE)1090-0268(1998)2:2(96)