Software architecture of the MOLAR-HRRT reconstruction engine

被引:22
作者
Johnson, CA [1 ]
Thada, S [1 ]
Rodriguez, M [1 ]
Zhao, YS [1 ]
Iano-Fletcher, AR [1 ]
Liow, JS [1 ]
Barker, WC [1 ]
Martino, RL [1 ]
Carson, RE [1 ]
机构
[1] NIH, Div Computat Biosci, Ctr Informat Technol, Bethesda, MD 20892 USA
来源
2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7 | 2004年
关键词
D O I
10.1109/NSSMIC.2004.1466744
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Motion-compensation OSEM List-mode Algorithm for Resolution-recovery Reconstruction (MOLAR) is a complete system for managing and performing iterative PET reconstructions. Although it was designed for use with the ECAT HRRT, its pluggable component architecture is readily extendable to any PET scanner, list-mode or frame-mode. List-mode data are stored on a distributed set of linked lists of event packets. Each event packet stores all information needed for one coincidence event. The resolution model uses a distance-based approximation and assumes separability of the radial and axial factors. Since the complete computation of the global sensitivity image Q (the denominator outside the sum in the OSEM update equation) requires a back-projection of all 4.5x10(9) possible LORs in the HRRT at all time increments in the scan frame and is thus intractable, we have devised an approximation in which the back projection is performed on only a randomized sub-sampling of LOR space. To test the randomized approach we generated 10 realizations of the Q image at various count levels and measured the average coefficient of variation (COV) per slice at each count level. We characterize the dependence of image noise on error in Q. We also provide a result demonstrating that we have achieved image resolution of less than 3 mm, a critical design goal.
引用
收藏
页码:3956 / 3960
页数:5
相关论文
共 8 条
[1]  
BARKER WC, 2004, IEEE NUCL SCI S MED, P187
[2]  
CAEY ME, 1995, P INT M FULL 3 DIM R, P67
[3]  
CARSON RE, 2003, IEEE NUCL SCI S MED, P6
[4]   Fast EM-like methods for maximum "a posteriori" estimates in emission tomography [J].
De Pierro, AR ;
Yamagishi, MEB .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (04) :280-288
[5]   ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA [J].
HUDSON, HM ;
LARKIN, RS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) :601-609
[6]   Propagation of errors from the sensitivity image in list mode reconstruction [J].
Qi, JY ;
Huesman, RH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (09) :1094-1099
[7]   New, faster, image-based scatter correction for 3D PET [J].
Watson, CC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) :1587-1594
[8]   The ECAT HRRT: Performance and first clinical application of the new high resolution research tomograph [J].
Wienhard, K ;
Schmand, M ;
Casey, ME ;
Baker, K ;
Bao, J ;
Eriksson, L ;
Jones, WF ;
Knoess, C ;
Lenox, M ;
Lercher, M ;
Luk, P ;
Michel, C ;
Reed, JH ;
Richerzhagen, N ;
Treffert, J ;
Vollmar, S ;
Young, JW ;
Heiss, WD ;
Nutt, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) :104-110