Effect of Modulation Index of Pulse Width Modulation Inverter on Total Harmonic Distortion for Sinusoidal

被引:0
|
作者
Aboadla, Ezzidin Hassan Elmabrouk [1 ]
Khan, Sheroz [1 ]
Habaebi, Mohamed Hadi [1 ]
Gunawan, Teddy [1 ]
Hamidah, Belal Ahmed [1 ]
Bin Yaacob, Mashkuri [1 ]
机构
[1] Int Islamic Univ Malaysia, Kulliyyah Engn, Dept Elect & Comp Engn, Kuala Lumpur, Malaysia
来源
2016 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS ENGINEERING (ICISE) | 2016年
关键词
Inverter; SPWM; Unipolar; Bipolar; Moduation index;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Knowing Total Harmonic Distortion (THD) content of voltage source inverter (VSI) is important and must be within the allowable range. Several schemes are suggested to mitigate THD and to produce as much a sinusoidal output signal as would be possible. One of such schemes is using a Sinusoidal Pulse Width Modulation SPWM-based inverter. SPWM is usually used in inverters for industrial applications. In this paper, a study of the performance of the SPWM technique is presented for a single phase H-bridge inverter. The SPWM scheme is modeled in MATLAB - Simulink. A bipolar and unipolar PWM technique are compared in this project as such techniques offer the features of effectively doubling the switching frequency of the output voltage. Under different conditions of modulation index, the pattern is utilized to estimate the harmonics. Simulation results for a full bridge single phase inverter using bipolar and unipolar SPWM schemes are presented.
引用
收藏
页码:192 / 196
页数:5
相关论文
empty
未找到相关数据