Comparison of the I-Gel and the Laryngeal Mask Airway Proseal during General Anesthesia: A Systematic Review and Meta-Analysis

被引:37
|
作者
Park, Sun Kyung [1 ]
Choi, Geun Joo [2 ]
Choi, Yun Suk [1 ]
Ahn, Eun Jin [3 ]
Kang, Hyun [2 ]
机构
[1] Jeju Natl Univ, Dept Anesthesiol & Pain Med, Coll Med, Jeju, South Korea
[2] Chung Ang Univ, Coll Med, Dept Anesthesiol & Pain Med, Seoul 156756, South Korea
[3] SungKyunKwan Univ Hosp, Dept Anesthesiol & Pain Med, Seoul, South Korea
来源
PLOS ONE | 2015年 / 10卷 / 03期
关键词
SUPRAGLOTTIC AIRWAY; LMA; CROSSOVER; PRESSURE;
D O I
10.1371/journal.pone.0119469
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives Conflicting results have been reported for the i-gel and the laryngeal mask airway proseal (LMA-P) during general anesthesia. The objective of the current investigation was to compare the efficacy and safety of the i-gel vs. the LMA-P during general anesthesia. Methods Two authors performed searches of MEDLINE, EMBASE, CENTRAL, and Google Scholar to identify randomized clinical trials that compared the LMA-P with the i-gel during general anesthesia. A meta -analysis was performed using both random and fixed-effect models. Publication bias was evaluated using Begg's funnel plot and Egger's linear regression test. Results Twelve randomized clinical trials met the eligibility criteria. There were no significant differences in insertion success rate at the first attempt (risk ratio [RR] 1.01, 95% confidence interval [CI] 0.97, 1.06), ease of insertion (RR 1.14, 95% CI 0.93, 1.39), oropharyngeal leak pressure (OLP) (MD -1.98, 95% CI -5.41, 1.45), quality of fiberoptic view (RR 1.00, 95% CI 0.91, 1.10) and success rate of gastric tube insertion (RR 1.07, 95% CI 0.98, 1.18) between the i-gel and the LMA-P, respectively. The i-gel had a shorter insertion time than the LMA-P (MD -3.99, 95% CI -7.13, -0.84) and a lower incidence of blood staining on the device (RR 0.26, 95% CI 0.14, 0.49), sore throat (RR 0.28, 95% CI 0.15, 0.50) and dysphagia (RR 0.27, 95% CI 0.10, 0.74). Conclusions Both devices were comparable in ease of insertion to insert and both had sufficient OLP to provide a reliable airway. Only a few minor complications were reported. The i-gel was found to have fewer complications (blood staining, sore throat, dysphagia) than the LMA-P and offers certain advantages over the LMA-P in adults under general anesthesia.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] The ProSeal Laryngeal Mask Airway is more effective than the LMA-Classic in pediatric anesthesia: a meta-analysis
    Zhang, Xiaolong
    Chen, Minghui
    Li, Quan
    JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (08) : 639 - 646
  • [22] Comparative efficacy and safety of the Ambu® AuraOnce™ laryngeal mask airway during general anaesthesia in adults: a systematic review and meta-analysis
    Baidya, D. K.
    Chandralekha
    Darlong, V.
    Pandey, R.
    Maitra, S.
    Khanna, P.
    ANAESTHESIA, 2014, 69 (09) : 1023 - 1032
  • [23] Comparison of fibrescope guided intubation via the classic laryngeal mask airway and i-gel in a manikin
    de Lloyd, L.
    Hodzovic, I.
    Voisey, S.
    Wilkes, A. R.
    Latto, I. P.
    ANAESTHESIA, 2010, 65 (01) : 36 - 43
  • [24] A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: A manikin study
    Michalek, P.
    Donaldson, W.
    Graham, C.
    Hinds, J. D.
    RESUSCITATION, 2010, 81 (01) : 74 - 77
  • [25] Comparing I-Gel to Proseal Laryngeal Mask Airways in Infants: A Prospective Randomised Clinical Study
    Oba, Sibel
    Turk, Hacer Sebnem
    Kilinc, Leyla
    Karaci, Birsen Eksioglu
    Islamoglu, Serkan
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2020, 48 (04) : 308 - 313
  • [26] Comparison of SaCoVLM™ video laryngeal mask-guided intubation and i-gel combined with flexible bronchoscopy-guided intubation in airway management during general anesthesia: a non-inferiority study
    Yan, Chun-ling
    Zhang, Yi-qi-yuan
    Chen, Ying
    Qv, Zong-yang
    Zuo, Ming-zhang
    BMC ANESTHESIOLOGY, 2022, 22 (01)
  • [27] Comparison of the laryngeal mask airway supreme and the i-gel in paralysed elderly patients A randomised controlled trial
    Kim, Myoung H.
    Lee, Jae H.
    Choi, Yong S.
    Park, Sujung
    Shin, Seokyung
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2018, 35 (08) : 598 - 604
  • [28] Crossover Comparison of the Laryngeal Mask Supreme™ and the i-gel™ in Simulated Difficult Airway Scenario in Anesthetized Patients
    Theiler, Lorenz G.
    Kleine-Brueggeney, Maren
    Kaiser, Dagmar
    Urwyler, Natalie
    Luyet, Cedric
    Vogt, Andreas
    Greif, Robert
    Unibe, M. M. E.
    ANESTHESIOLOGY, 2009, 111 (01) : 55 - 62
  • [29] Prewarming i-gel laryngeal mask for mechanical ventilation: a meta-analysis of randomised control trials and trial sequential analysis
    Zheng, Jianqiao
    Du, Li
    Wang, Jia
    Zhang, Lu
    Chen, Guo
    BMJ OPEN, 2021, 11 (08):
  • [30] Safety and Limitation of the I-gel Laryngeal mask airway in the Lithotomy Position. An Observational study
    Kamel, Walid Y.
    Haggag, Addham Magdy