Effect of shading and evaporative cooling of glass cover on the performance of evacuated tube-augmented solar still

被引:36
作者
Bhargva, Mohit [1 ]
Yadav, Avadhesh [1 ]
机构
[1] Natl Inst Technol Kurukshetra, Mech Engn Dept, Kurukshetra 136119, Haryana, India
关键词
Solar still; Shading and cooling; Evacuated tube collector; Productivity; Efficiency; THERMAL PERFORMANCE; AIR COLLECTOR; PRODUCTIVITY; SINGLE; HEAT; HYBRID;
D O I
10.1007/s10668-019-00375-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Solar still is a promising device used worldwide for water distillation due to its simple design, easy construction and low cost. However, the freshwater output from a solar still is moderate. Several active techniques have been emerged over the years to solve this problem. In this paper, an experimental study is carried out on a single-slope solar still augmented with an evacuated tube collector (ETC) and a heat exchanger working on thermosyphon. The effects of shading and evaporative cooling of glass cover on the active solar still performance were explored and analyzed on separate days under the meteorological conditions of Kurukshetra, India. The experiments were conducted at a constant water depth of 4 cm. The main aim of this study is to enhance the productivity and efficiency of ETC-coupled solar still by increasing the condensation rate. The experimental results showed remarkable increment in freshwater productivity of the still with a maximum of 2114 ml/day achieved for the case of 1/2 shading and cooling of glass cover. An increase of 16.4% and 3.8% in freshwater productivity and overall efficiency was achieved with 1/2 shading and cooling of glass cover in comparison with solar still without glass cover shading and cooling. The solar still performance was decreased when the shading and cooling are done on more than half the area of glass cover.
引用
收藏
页码:4125 / 4143
页数:19
相关论文
共 24 条
[1]   The effect of cover tilt angle of a double slope solar still on the productivity in summer and winter seasons [J].
Abderachid, Trad ;
Abdenacer, Kaabi .
DESALINATION AND WATER TREATMENT, 2015, 56 (10) :2584-2592
[2]   Theoretical and experimental analysis of pin fins absorber solar still [J].
Ali, Chaouki ;
Rabhi, Kamel ;
Nciri, Rached ;
Nasri, Faouzi ;
Attyaoui, Slimen .
DESALINATION AND WATER TREATMENT, 2015, 56 (07) :1705-1711
[3]   Effect of sponge liner on the internal heat transfer coefficients in a simple solar still [J].
Arjunan, T. V. ;
Aybar, H. S. ;
Nedunchezhian, N. .
DESALINATION AND WATER TREATMENT, 2011, 29 (1-3) :271-284
[4]   Experimental Analysis of an Improved Solar Still System with Cooling Fan and Preheating Oil [J].
Bani-Hani E. ;
Qassem H. ;
Kandari M.A. ;
Azmi S.A. ;
Khalid M. ;
Bu-Mijdad H. ;
Khanafer K. ;
Sedaghat A. .
1600, Bellwether Publishing, Ltd. (114) :55-71
[5]   Contributing to the improvement of the production of solar still [J].
Ben Bacha, Habib ;
Zhani, Khalifa .
DESALINATION AND WATER TREATMENT, 2013, 51 (4-6) :1310-1318
[6]   Water desalination system using solar heat: A review [J].
Chandrashekara, M. ;
Yadav, Avadhesh .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 67 :1308-1330
[7]   Experimental and theoretical performance of finned-single effect solar still [J].
El-Naggar, M. ;
El-Sebaii, A. A. ;
Ramadan, M. R. I. ;
Aboul-Enein, S. .
DESALINATION AND WATER TREATMENT, 2016, 57 (37) :17151-17166
[8]   The effect of the water depth on the productivity for single and double basin double slope glass solar stills [J].
Elango, T. ;
Murugavel, K. Kalidasa .
DESALINATION, 2015, 359 :82-91
[9]   Enhancing the productivity of double-slope single-basin solar still with internal and external modifications [J].
Gnanaraj, S. Joe Patrick ;
Ramachandran, S. ;
Christopher, David Santosh .
INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2018, 39 (08) :777-782
[10]   Improving the basin type solar still performances using a vertical rotating wick [J].
Haddad, Zakaria ;
Chaker, Abla ;
Rahmani, Ahmed .
DESALINATION, 2017, 418 :71-78