Comparison of distal radioulnar joint reconstructions using an active joint motion simulator

被引:44
作者
Gofton, WT [1 ]
Gordon, KD [1 ]
Dunning, CE [1 ]
Johnson, JA [1 ]
King, GJW [1 ]
机构
[1] Univ Western Ontario, Dept Surg & Biomed Engn, St Josephs Hlth Ctr, Hand & Upper Limb Ctr,Bioengn Lab, London, ON, Canada
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2005年 / 30A卷 / 04期
关键词
active; kinematics; joint; distal radioulnar; reconstruction;
D O I
10.1016/j.jhsa.2004.12.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Distal radioulnar joint (DRUJ) instability can result in pain and functional disability. Numerous DRUJ reconstructive options have been described with minimal biomechanical analysis. The purpose of this study was to evaluate the ability of 4 well-described DRUJ reconstructions to restore joint kinematics using a dynamic, motion-controlled simulator. Methods: Eleven cadaveric upper extremities had computer-controlled simulated active forearm rotation. joint kinematics were quantified by using an electromagnetic tracking system. We compared the passive and simulated active kinematics of the intact, unstable, and reconstructed DRUJ (capsular repair, 2 described radioulnar ligament reconstructions, and a radioulnar tethering procedure). Results: All reconstructions improved significantly the kinematics of the unstable DRUJ. The capsule repair restored simulated active joint kinematics closest to the intact DRUJ. Conclusions: All 4 reconstructions improved DRUJ stability significantly. The capsule repair most closely matched intact DRUJ kinematics and the radioulnar ligament reconstructions were found to be superior to a radioulnar tethering procedure.
引用
收藏
页码:733 / 742
页数:10
相关论文
共 41 条
[12]   Development of a motion-controlled in vitro elbow testing system [J].
Dunning, CE ;
Gordon, KD ;
King, GJW ;
Johnson, JA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (03) :405-411
[13]  
FULKERSON JP, 1978, CLIN ORTHOP RELAT R, P179
[14]   Influence of the pronator quadratus and supinator muscle load on DRUJ stability [J].
Gordon, KD ;
Dunning, CE ;
Johnson, JA ;
King, GJW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (06) :943-950
[15]   AN ANATOMIC AND MECHANICAL STUDY OF THE INTEROSSEOUS MEMBRANE OF THE FOREARM - PATHOMECHANICS OF PROXIMAL MIGRATION OF THE RADIUS [J].
HOTCHKISS, RN ;
AN, KN ;
SOWA, DT ;
BASTA, S ;
WEILAND, AJ .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1989, 14 (02) :256-261
[16]   ULNOTRIQUETRAL AUGMENTATION TENODESIS - A RECONSTRUCTIVE PROCEDURE FOR DORSAL SUBLUXATION OF THE DISTAL RADIOULNAR JOINT [J].
HUI, FC ;
LINSCHEID, RL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1982, 7 (03) :230-236
[17]  
HUNTER JM, 1991, HAND CLIN, V7, P365
[18]   TREATMENT OF CHRONIC POSTTRAUMATIC DORSAL SUBLUXATION OF THE DISTAL ULNA BY HEMIRESECTION-INTERPOSITION ARTHROPLASTY [J].
IMBRIGLIA, JE ;
MATTHEWS, D .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (05) :899-907
[19]   Simulation of elbow and forearm motion in vitro using a load controlled testing apparatus [J].
Johnson, JA ;
Rath, DA ;
Dunning, CE ;
Roth, SE ;
King, GJW .
JOURNAL OF BIOMECHANICS, 2000, 33 (05) :635-639
[20]  
JOHNSON RK, 1992, CLIN ORTHOP RELAT R, P130