The effect of phosphorylcholine-coated materials on the inflammatory response and fibrous capsule formation:: In vitro and in vivo observations

被引:51
作者
Goreish, HH
Lewis, AL
Rose, S
Lloyd, AW
机构
[1] Biocompatibles UK Ltd, Farnham GU9 8QL, Surrey, England
[2] Univ Brighton, Sch Pharm & Biomol Sci, Biomed Mat Res Grp, Brighton BN2 4GJ, E Sussex, England
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A | 2004年 / 68A卷 / 01期
关键词
phosphorylcholine polymer coating; cellular adhesion; inflammatory response; fibrous capsule formation;
D O I
10.1002/jbm.a.10141
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Several experiments were performed to compare the in vitro adhesion of human macrophage and granulocyte inflammatory cells to polyethylene terephthalate substrate and the same coated with a phosphorylcholine (PC)-based polymer. The inclusion of various types of serum at different stages in the assay indicated that protein adsorption and passivation of the surface may be responsible for reducing the number of inflammatory cells adhering to the uncoated polyethylene terephthalate controls. In all of the assays performed there was a statistically significant reduction (p < 0.05; analysis of variance) of the number of inflammatory cells adhering to the PC-coated samples, linked to the ability of these surfaces to resist protein adhesion. Implantations of PC-coated stainless steel and high-density polyethylene USP control samples were made in a rabbit intramuscular model. Histological examination of the number of inflammatory cells present around the implant sites 4 weeks postimplantation showed there were 40% less cells associated with the PC-coated samples compared with control, but this was not statistically significant. Fibrous capsule thickness, however, whereas marginally less at 4 weeks, had almost completely regressed for the PC-coated sample at 13 weeks postimplantation and was statistically thinner (p < 0.01; Mann-Whitney U test) than the high-density polyethylene USP control. These findings support the view that low biointeractions observed for PC-based technology in vitro can result in reduced inflammation and foreign body reaction in vivo. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 33 条
  • [1] EFFECT OF IMPLANTATION SITE ON PHAGOCYTE POLYMER INTERACTION AND FIBROUS CAPSULE FORMATION
    BAKKER, D
    VANBLITTERSWIJK, CA
    HESSELING, SC
    GROTE, JJ
    DAEMS, WT
    [J]. BIOMATERIALS, 1988, 9 (01) : 14 - 23
  • [2] WIDESPREAD DISSEMINATION OF METAL DEBRIS FROM IMPLANTS
    CASE, CP
    LANGKAMER, VG
    JAMES, C
    PALMER, MR
    KEMP, AJ
    HEAP, PF
    SOLOMON, L
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05): : 701 - 712
  • [3] ADHESION AND CYTOKINE PRODUCTION BY MONOCYTES ON POLY(2-METHACRYLOYLOXYETHYL PHOSPHORYLCHOLINE-CO-ALKYL METHACRYLATE)-COATED POLYMERS
    DEFIFE, KM
    YUN, JK
    AZEEZ, A
    STACK, S
    ISHIHARA, K
    NAKABAYASHI, N
    COLTON, E
    ANDERSON, JM
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (04): : 431 - 439
  • [4] Osseointegration on metallic implant surfaces: Effects of microgeometry and growth factor treatment
    Frenkel, SR
    Simon, J
    Alexander, H
    Dennis, M
    Ricci, JL
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (06): : 706 - 713
  • [5] Ishihara K, 1998, J BIOMED MATER RES, V39, P323, DOI 10.1002/(SICI)1097-4636(199802)39:2<323::AID-JBM21>3.3.CO
  • [6] 2-0
  • [7] Reduced protein adsorption on novel phospholipid polymers
    Ishihara, K
    Iwasaki, Y
    [J]. JOURNAL OF BIOMATERIALS APPLICATIONS, 1998, 13 (02) : 111 - 127
  • [8] Reduction of surface-induced inflammatory reaction on PLGA/MPC polymer blend
    Iwasaki, Y
    Sawada, S
    Ishihara, K
    Khang, G
    Lee, HB
    [J]. BIOMATERIALS, 2002, 23 (18) : 3897 - 3903
  • [9] JOHNSON J, 1997, BIOMED SCI INSTRUM, V34, P47
  • [10] IS THE VROMAN EFFECT OF IMPORTANCE IN THE INTERACTION OF BLOOD WITH ARTIFICIAL MATERIALS
    LEONARD, EF
    VROMAN, L
    [J]. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1991, 3 (01) : 95 - 107