Posterior chamber phakic intraocular lens implantation for high myopia

被引:0
作者
Shen, Y [1 ]
Du, CX [1 ]
Gu, YS [1 ]
Wang, J [1 ]
机构
[1] Zhejiang Univ, Coll Med, Affiliated Hosp 1, Dept Ophthalmol, Hangzhou 310003, Peoples R China
关键词
myopia; intraocular lens; implantation;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. To evaluate the efficacy, safety and stability of posterior chamber phakic intraocular lens (PIOLs) implantation for the correction of high myopia. Methods. Thirty-nine eyes of twenty patients with high myopia ( between -11.75 and -25.75 diopters) had a posterior chamber PIOL (Staar ICL) implanted. During 6 - 48 months' follow-up, visual acuity, refraction, intraocular pressure (IOP), corneal reaction and space between crystal lens and intraocular lens (IOLs) were tested. Results. Successful implantation was achieved in all patients. Visual acuity without correction greater than 0.5 was found in 34 eyes at 1 day and 3 months postoperatively. Thirty-five eyes maintained a low negative power of refraction (-1.42 +/- 1.32 doipters), which did not prevent the patients from most of their daily activities. During 3 - 48 months' follow-up, refraction was stable and no cornea edema and glaucoma was found. Two eyes of one patient had corticosteroid glaucoma and another eye showed cataractogenesis under anterior capsular membrane. Conclusion. Posterior chamber PIOL implantation is predictable, safe, and effective in the correction of high myopia, and its indications should be carefully selected.
引用
收藏
页码:1523 / 1526
页数:4
相关论文
共 15 条
[1]   Phakic posterior chamber lenses for high myopia: Functional and anatomical outcomes [J].
Arne, JL ;
Lesueur, LC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (03) :369-374
[2]   INCIDENCE OF RETINAL-DETACHMENT FOLLOWING CLEAR-LENS EXTRACTION IN MYOPIC PATIENTS - RETROSPECTIVE ANALYSIS [J].
BARRAQUER, C ;
CAVELIER, C ;
MEJIA, LF .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (03) :336-339
[3]   Phakic posterior chamber intraocular lens for the correction of anisometropia and treatment of amblyopia [J].
BenEzra, D ;
Cohen, E ;
Karshai, I .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 130 (03) :292-296
[4]  
Davidorf JM, 1998, J REFRACT SURG, V14, P306
[5]   Posterior chamber myopia lenses in phakic eyes [J].
Fechner, PU ;
Haigis, W ;
Wichmann, W .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (02) :178-182
[6]   Cataract development after implantation of the Staar Collamer posterior chamber phakic lens [J].
Fink, AM ;
Gore, C ;
Rosen, E .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (02) :278-282
[7]   Safety of posterior chamber phakic intraocular lenses for the correction of high myopia -: Anterior segment changes after posterior chamber phakic intraocular lens implantation [J].
Jiménez-Alfaro, I ;
del Castillo, JMB ;
García-Feijoó, J ;
de Bernabé, JGG ;
de la Iglesia, JMS .
OPHTHALMOLOGY, 2001, 108 (01) :90-99
[8]   Long-term results of clear lens extraction for severe myopia [J].
Lee, KH ;
Lee, JH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (10) :1411-1415
[9]   Phakic posterior chamber lens implantation in children with high myopia [J].
Lesueur, LC ;
Arne, JL .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (12) :1571-1575
[10]   Staar Collamer posterior chamber phakic intraocular lens to correct myopia and hyperopia [J].
Rosen, E ;
Gore, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (05) :596-606