Identification of dabigatran etexilate major degradation pathways by liquid chromatography coupled to multi stage high-resolution mass spectrometry

被引:7
|
作者
Amrani, Fatma [1 ]
Secretan, Philippe-Henri [1 ]
Sadou-Yaye, Hassane [1 ,2 ]
Aymes-Chodur, Caroline [1 ]
Bernard, Melisande [1 ,3 ]
Solgadi, Audrey [4 ]
Yagoubi, Najet [1 ]
Do, Bernard [1 ,3 ]
机构
[1] Univ Paris Saclay, UFR Pharm, Grp Mat & Sante, Inst Innovat Therapeut, F-92296 Chatenay Malabry, France
[2] Grp Hosp Pitie Salpetriere, AP HP, Serv Pharm, F-75013 Paris, France
[3] Agence Gen Equipements & Prod Sante, AP HP, Dept Controle Qualite & Dev Analyt, F-75005 Paris, France
[4] Univ Paris Saclay, UFR Pharm, SAMM, Inst Innovat Therapeut, F-92296 Chatenay Malabry, France
关键词
DIRECT THROMBIN INHIBITOR; RIVAROXABAN; IMPURITIES; PLASMA; MS/MS; ASSAY;
D O I
10.1039/c5ra04251h
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Dabigatran etexilate (DABET) is an oral direct thrombin inhibitor that has been approved for the prevention of blood clot formation. As the active pharmaceutical ingredient (API) may undergo degradation, leading to drug activity loss or to the occurrence of adverse effects associated with degradation products, thorough knowledge of the API's stability profile is required. Since very few studies have been reported on the drug stability profile, a study related to DABET's behaviour under stress conditions was carried out in order to identify its major degradation pathways. DABET was subjected to hydrolytic (acidic and alkaline), oxidative, photolytic and thermal stress, as per ICH-specified conditions. Up to ten degradation products along with dabigatran, the active metabolite of DABET, were formed and detected by reverse phase liquid chromatography in gradient mode (LC) coupled to UV and mass spectrometry (UV-MS). Structures were determined by elemental composition determination and study of the fragmentation patterns, using high-resolution mass spectrometry in multistage mode (HR-MSn). Under hydrolytic stress conditions, O-dealkylation may occur and formation of benzimidic acid derivatives was also observed. DABET was shown to be much less susceptible to photolysis and oxidative stress, even if N-dealkylation was highlighted. In view of the structures identified, various degradation pathways of DABET have been proposed.
引用
收藏
页码:45068 / 45081
页数:14
相关论文
共 50 条
  • [1] Liquid chromatography coupled to high-resolution mass spectrometry for nut classification and marker identification
    Campmajo, Guillem
    Saurina, Javier
    Nunez, Oscar
    FOOD CONTROL, 2023, 152
  • [2] Identification of the New Metabolite of Nebivolol Using Liquid Chromatography Coupled with High-Resolution Mass Spectrometry and Chemometrics
    Trawinski, Jakub
    Wronski, Michal
    Gawlik, Maciej
    Skibinski, Robert
    MOLECULES, 2022, 27 (03):
  • [3] Identification of tiagabine degradation products using liquid chromatography with electrospray ionization multistage mass spectrometry and ultra-performance liquid chromatography/high-resolution mass spectrometry
    Hubert-Roux, Marie
    Skiba, Mohamed
    Sughir, Abdussalam
    Lahiani-Skiba, Malika
    Olivier-Chanu, Fabienne
    Levacher, Vincent
    Lange, Catherine M.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (03) : 287 - 296
  • [4] Degradation of β-casomorphins and identification of degradation products during yoghurt processing using liquid chromatography coupled with high resolution mass spectrometry
    Duc Doan Nguyen
    Busetti, Francesco
    Johnson, Stuart Keith
    Solah, Vicky Ann
    FOOD RESEARCH INTERNATIONAL, 2018, 106 : 98 - 104
  • [5] Machine learning-assisted identification of environmental pollutants by liquid chromatography coupled with high-resolution mass spectrometry
    Wang, Haotian
    Zhong, Laijin
    Su, Wenyuan
    Ruan, Ting
    Jiang, Guibin
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2024, 180
  • [6] Identification of Auxin Metabolites in Brassicaceae by Ultra-Performance Liquid Chromatography Coupled with High-Resolution Mass Spectrometry
    Revelou, Panagiota-Kyriaki
    Kokotou, Maroula G.
    Constantinou-Kokotou, Violetta
    MOLECULES, 2019, 24 (14):
  • [7] Quantitative and confirmative performance of liquid chromatography coupled to high-resolution mass spectrometry compared to tandem mass spectrometry
    Kaufmann, Anton
    Butcher, Patrick
    Maden, Kathryn
    Walker, Stephan
    Widmer, Miryam
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (07) : 979 - 992
  • [8] Quantitation of carbohydrate monomers and dimers by liquid chromatography coupled with high-resolution mass spectrometry
    Barzen-Hanson, Krista A.
    Wilkes, Rebecca A.
    Aristilde, Ludmilla
    CARBOHYDRATE RESEARCH, 2018, 468 : 30 - 35
  • [9] Identification and structural characterization of major stress degradation products of halcinonide by liquid chromatography-high-resolution mass spectrometry
    Giri, Shivraj
    Badgujar, Devendra
    Paritala, Sree Teja
    Sharma, Nitish
    BIOMEDICAL CHROMATOGRAPHY, 2023, 37 (11)
  • [10] Identification and structural characterization of major stress degradation products of halcinonide by liquid chromatography-high-resolution mass spectrometry
    Giri, Shivraj
    Badgujar, Devendra
    Paritala, Sree Teja
    Sharma, Nitish
    BIOMEDICAL CHROMATOGRAPHY, 2023,