Magnetic resonance elastography SE-EPI vs GRE sequences at 3T in a pediatric population with liver disease

被引:22
作者
Calle-Toro, Juan S. [1 ]
Serai, Suraj D. [1 ,4 ]
Hartung, Erum A. [2 ,4 ]
Goldberg, David J. [3 ,4 ]
Bolster, Bradley D., Jr. [5 ]
Darge, Kassa [1 ,4 ]
Anupindi, Sudha A. [1 ,4 ]
机构
[1] Childrens Hosp Philadelphia, Dept Radiol, Div Body Imaging, 3401 Civ Ctr Blvd, Philadelphia, PA 19104 USA
[2] Childrens Hosp Philadelphia, Dept Pediat, Div Nephrol, Philadelphia, PA 19104 USA
[3] Childrens Hosp Philadelphia, Dept Pediat, Div Cardiol, Philadelphia, PA 19104 USA
[4] Univ Penn, Perelman Sch Med, Philadelphia, PA 19104 USA
[5] Siemens Healthineers, Malvern, PA USA
关键词
Fibrosis; Liver; Magnetic resonance imaging; MR elastography; GRE MRE; SE-EPI MRE; HEPATIC-FIBROSIS; MR ELASTOGRAPHY; STIFFNESS; BIOPSY; AGREEMENT;
D O I
10.1007/s00261-018-1884-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe goal of our study is to compare hepatic stiffness measures using gradient-recalled echo (GRE) versus spin-echo echo planar imaging (SE-EPI)-based MR Elastography (MRE) at 3T used to measure hepatic stiffness in a patients with suspected liver diseases.Materials and methodsThis retrospective study included 52 patients with liver disease who underwent a 3T MRE exam including both an investigational SE-EPI-based technique and a product GRE-based technique. Regions of interest (ROI) were placed on the elastograms to measure elastography-derived liver stiffness as well as the area included within the ROIs. The mean liver stiffness values and area of ROIs were compared.ResultsThe mean liver stiffness was 3.72 kilopascal (kPa) 1.29 using GRE MRE and 3.78kPa +/- 1.13 using SE-EPI MRE. Measurement of liver stiffness showed excellent agreement between the two pulse sequences with a mean bias of -0.1kPa (range -1.8 to 1.7kPa) between sequences. The mean measurable ROI area was higher with SE-EPI (313.8cm(2)+/- 213.8) than with the GRE technique (208.6cm(2)+/- 114.8), and the difference was statistically significant (P<0.05).Conclusionsp id=Par4Our data shows excellent agreement of measured liver stiffness between GRE and SE-EPI-based sequences at 3T. Our results show the advantage of a SE-EPI MRE sequence in terms of image quality, ROI size and acquisition time with equivalent liver stiffness measurements as compared to GRE-MRE sequence.
引用
收藏
页码:894 / 902
页数:9
相关论文
共 42 条
[1]   Clinical and Ultrasonographic Measurement of Liver Size in Normal Children [J].
Amatya, Puja ;
Shah, Dheeraj ;
Gupta, Natasha ;
Bhatta, Nisha K. .
INDIAN JOURNAL OF PEDIATRICS, 2014, 81 (05) :441-445
[2]  
[Anonymous], 2012, TUTOR QUANT METHODS, DOI DOI https://doi.org/10.20982/tqmp.08.1.p023
[3]  
[Anonymous], 2015, LANCET, DOI [DOI 10.1016/S0140-6736(14)61746-3, 10.1016/S0140-6736]
[4]   Magnetic resonance elastography of healthy livers at 3.0 T: Normal liver stiffness measured by SE-EPI and GRE [J].
Bae, Jae Seok ;
Lee, Jeong Min ;
Park, Sae-Jin ;
Lee, Kyung Bun ;
Han, Joon Koo .
EUROPEAN JOURNAL OF RADIOLOGY, 2018, 107 :46-53
[5]   Sampling variability of liver fibrosis in chronic hepatitis C [J].
Bedossa, P ;
Dargère, D ;
Paradis, V .
HEPATOLOGY, 2003, 38 (06) :1449-1457
[6]   Current concepts: Liver biopsy. [J].
Bravo, AA ;
Sheth, SG ;
Chopra, S .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (07) :495-500
[7]   Practices of liver biopsy in France: Results of a prospective nationwide survey [J].
Cadranel, JF ;
Rufat, P ;
Degos, F .
HEPATOLOGY, 2000, 32 (03) :477-481
[8]  
Chang W, 2016, RADIOLOGY
[9]   Feasibility and agreement of stiffness measurements using gradient-echo and spin-echo MR elastography sequences in unselected patients undergoing liver MRI [J].
Cunha, Guilherme Moura ;
Glaser, Kevin J. ;
Bergman, Anke ;
Luz, Rodrigo P. ;
De Figueiredo, Eduardo H. ;
Proenca Lobo Lopes, Flavia Paiva .
BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1087)
[10]   ECHO-PLANAR IMAGING [J].
DELAPAZ, RL .
RADIOGRAPHICS, 1994, 14 (05) :1045-1058