Is polytetrafluoroethylene circular banding an effective technique for treatment of high-flow vascular access-induced steal syndrome?

被引:2
|
作者
El-Laboudy, Medhat E. [1 ,2 ]
Sorour, Waleed A. [1 ]
Tawfik, Ahmed M. [1 ]
机构
[1] Zagazig Univ, Fac Med, Dept Vasc Surg, Zagazig, Egypt
[2] Alnoor Specialist Hosp, Mecca, Saudi Arabia
关键词
banding; high flow; steal syndrome; polytetrafluoroethylene; TREATMENT STRATEGIES; HEMODIALYSIS; INFLOW;
D O I
10.4103/ejs.ejs_222_19
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective The aim was to evaluate the efficacy and safety of polytetrafluoroethylene (PTFE) banding for treatment of high-flow vascular access-induced steal syndrome. Patients and methods The prospective study was conducted at Vascular Surgery Departments, Zagazig University Hospitals, Egypt and Alnoor Specialist Hospital, Makkah, Saudi Arabia from February 2016 to October 2019. The study included 19 cases (11 women). The mean age was 54 years. The access was brachiocephalic; arteriovenous fistula (AVF) in 11 patients, transposed brachiobasilic AVF in three patients and upper-arm synthetic in five patients. The mean duration of access was 1.2 years. Stages of steal were (stage II: three cases, stage III: nine cases, stage IV: seven cases). Results There was complete relief in 15 (79%) patients, while only partial improvement in four (21%) patients; one patient achieved complete relief with another banding, one patient continued to use his access with partial (but tolerable) symptomatic relief, one patient required distal revascularization and interval ligation, and the remaining patients underwent ligation. The average initial flow in native AVF was 2074 ml/min and in synthetic access was 2437 ml/min, and the average flow reduction after banding was 1025 ml/min (49%) in AVF and was 1247 ml/min (51%) in synthetic access. Only minor complications occurred in the form of cellulitis in two cases and mild bleeding in one case. Banding-related thrombectomy was done in three (16%) patients. Follow-up was for 1 year. Primary patency was 74 and 63% at 6 and 12 months, respectively, and secondary patency was 84 and 74% at 6 and 12 months, respectively. Conclusion PTFE banding is a simple technique to preserve the access function and treat symptoms of steal caused by high flow access. It is less time consuming, with lesser complications and accepted success rate and can be done as a day case procedure when compared with bypass techniques. So, PTFE banding can be used as an initial successful procedure for treating steal associated with high-flow access.
引用
收藏
页码:387 / 392
页数:6
相关论文
共 3 条
  • [1] Modified MILLER banding procedure for managing high-flow access and dialysis-associated steal syndrome
    Shintaku, Sadanori
    Kawanishi, Hideki
    Moriishi, Misaki
    Banshodani, Masataka
    Ago, Rika
    Tsuchiya, Shinichiro
    JOURNAL OF VASCULAR ACCESS, 2015, 16 (03) : 227 - 232
  • [2] TECHNIQUE OF CIRCULAR NARROWING WITH A POLYTETRAFLUOROETHYLENE GRAFT IN PATIENTS WITH HIGH-FLOW ARTERIOVENOUS FISTULA: MID-TERM RESULTS
    Demir, Deniz
    Tosun, Ali
    Kahraman, Nail
    Ozsin, Kadir Kaan
    Sanri, Umut Serhat
    Kocaslan, Aydemir
    Korkmaz, Ufuk Turan
    Goncu, Mehmet Tugrul
    ACTA MEDICA MEDITERRANEA, 2017, 33 (04): : 587 - 591
  • [3] One-year efficacy of the RUDI technique for flow reduction in high-flow autologous brachial artery-based hemodialysis vascular access
    Vaes, Roel H. D.
    van Loon, Magda
    Vaes, Selma M. M.
    Cuypers, Philippe
    Tordoir, Jan H.
    Scheltinga, Marc R.
    JOURNAL OF VASCULAR ACCESS, 2015, 16 : S96 - S101