SiPM dynamic range for CEPC scintillator-based electromagnetic calorimeter

被引:0
|
作者
Niu, Y. [1 ,2 ,3 ]
Shi, Y. [1 ,2 ,3 ]
Zhao, H. [4 ]
Zhang, Y. [1 ,2 ,3 ]
Ruan, M. [4 ]
Liu, J. [1 ,2 ,3 ]
机构
[1] State Key Lab Particle Detect & Elect, Beijing 100049, Peoples R China
[2] State Key Lab Particle Detect & Elect, Hefei 230026, Peoples R China
[3] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
[4] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
来源
JOURNAL OF INSTRUMENTATION | 2021年 / 16卷 / 12期
基金
中国国家自然科学基金;
关键词
Calorimeter methods; Calorimeters; Scintillators; scintillation and light emission processes (solid; gas and liquid scintillators);
D O I
10.1088/1748-0221/16/12/T12008
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high-granularity scintillator calorimeter readout with silicon photomultipliers (SiPMs) is an electromagnetic calorimeter (ECAL) candidate for experiments at the Circular Electron Positron Collider (CEPC). A critical design parameter of this ECAL candidate is the dynamic range of the SiPMs. This study investigates the SiPM dynamic range required for the CEPC scintillator ECAL. A model is developed on the basis of the operation principles of SiPMs to describe the response of an SiPM to light pulses within one recovery period by considering the cross-talk effect, photon detection efficiency, and number of pixels. The response curve of a 10000-pixel SiPM predicted by the model is consistent with the measured curve within 2% for an incident light pulse of up to 12000 photons. The intrinsic fluctuations of the SiPM response naturally exist in this model, and the correction of the saturation effect in the SiPM response is investigated. Monte Carlo (MC) simulation shows that the algorithm can restore the response linearity of an SiPM for an incident light pulse in which the number of photons is up to around six times the number of SiPM pixels. The model and correction program are implemented for full simulation of the ZH production Z -> nu nu H -> gamma gamma channel to evaluate the impact of the SiPM dynamic range of the CEPC scintillator ECAL on the reconstructed Higgs boson mass and the sensitivity to the Higgs signal in this channel. The results show that the CEPC scintillator ECAL equipped with no less than 4000 SiPM pixels and operated with a light yield of 20 photon-electrons per channel for a single minimum ionizing particle can meet the requirements for Higgs boson precision measurement in the di-photon channel at the CEPC.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] A LIQUID SCINTILLATOR-BASED CONTINUOUS RADIO CHROMATOGRAM SCANNER
    SPROTT, WE
    JOURNAL OF CHROMATOGRAPHY, 1965, 17 (02): : 355 - &
  • [42] Characterizing the response of a scintillator-based detector to single electrons
    Sang, Xiahan
    LeBeau, James M.
    ULTRAMICROSCOPY, 2016, 161 : 3 - 9
  • [43] Scintillator-based fast ion loss measurements in the EAST
    Chang, J. F.
    Isobe, M.
    Ogawa, K.
    Huang, J.
    Wu, C. R.
    Xu, Z.
    Jin, Z.
    Lin, S. Y.
    Hu, L. Q.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [44] CASTER - a scintillator-based Black Hole Finder Probe
    Paciesas, WS
    Case, G
    Cherry, ML
    Cravens, J
    Guzik, TG
    Hurley, K
    Kippen, RM
    Ryan, JM
    Macri, JM
    McConnell, ML
    Miller, RS
    Schaefer, BE
    Stacy, JG
    Wefel, JR
    Vestrand, WT
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 417 - 421
  • [45] Characteristics of molded polystyrene scintillator for electromagnetic calorimeter of the PHENIX apparatus
    Belikov, SV
    White, S
    Gutnikov, YE
    Denisov, AG
    Dyachkov, AI
    Zharkov, VV
    Kistenev, EP
    Kochetkov, VI
    Makeev, AV
    Mayatskii, VA
    Melnikov, EA
    Usachev, AP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1996, 39 (04) : 498 - 505
  • [46] Electromagnetic shower properties in a lead-scintillator sampling calorimeter
    Kotwal, Ashutosh V.
    Hays, Christopher
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 729 : 25 - 35
  • [47] Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
    Francis, K.
    Repond, J.
    Schlereth, J.
    Smith, J.
    Xia, L.
    Baldolemar, E.
    Li, J.
    Park, S. T.
    Sosebee, M.
    White, A. P.
    Yu, J.
    Eigen, G.
    Mikami, Y.
    Watson, N. K.
    Thomson, M. A.
    Ward, D. R.
    Benchekroun, D.
    Hoummada, A.
    Khoulaki, Y.
    Apostolakis, J.
    Dotti, A.
    Folger, G.
    Ivantchenko, V.
    Ribon, A.
    Uzhinskiy, V.
    Carloganu, C.
    Gay, P.
    Manen, S.
    Royer, L.
    Tytgat, M.
    Zaganidis, N.
    Blazey, G. C.
    Dyshkant, A.
    Lima, J. G. R.
    Zutshi, V.
    Hostachy, J. -Y.
    Morin, L.
    Cornett, U.
    David, D.
    Ebrahimi, A.
    Falley, G.
    Gadow, K.
    Goettlicher, P.
    Guenter, C.
    Hartbrich, O.
    Hermberg, B.
    Karstensen, S.
    Krivan, F.
    Krueger, K.
    Lutz, B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 763 : 278 - 289
  • [48] CASTER - a scintillator-based black hole finder probe
    McConnell, ML
    Cherry, ML
    Guzik, TG
    Kippen, RM
    Ryan, JM
    Macri, JM
    Miller, RS
    Paciesas, WS
    Schaefer, BE
    Stacy, JG
    Wefel, JP
    Vestrand, WT
    UV AND GAMMA-RAY SPACE TELESCOPE SYSTEMS, PTS 1 AND 2, 2004, 5488 : 944 - 955
  • [49] A LEAD LIQUID SCINTILLATOR ELECTROMAGNETIC CALORIMETER FOR DIRECT PHOTON PHYSICS
    BONESINI, M
    BONVIN, E
    BOOTH, PSL
    BORTOLETTO, D
    CARROLL, LJ
    CASS, AJ
    CAVALLI, D
    CECCHET, G
    COSTA, G
    DONNAT, M
    DORSAZ, PA
    EDWARDS, DN
    FISCHER, JR
    FLURI, L
    FRAME, D
    GIANOTTI, F
    JACK, S
    JACKSON, JN
    KELLY, M
    KIENZLEFOCACCI, MN
    LUCOCK, R
    LYNCH, JG
    MANDELLI, L
    MARTIN, M
    MATHYS, L
    MAXWELL, A
    MAZZANTI, M
    MYERSCOUGH, JJ
    NEGUS, PJ
    PENSOTTIRANCOITA, S
    PERINI, L
    PERRIN, D
    PERRIN, E
    RANGE, WH
    ROSSELET, L
    RUTSCHMANN, J
    SNOW, SW
    TAMBORINI, M
    THOMPSON, AS
    TURNBULL, RM
    WELLS, J
    WERLEN, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 261 (03): : 471 - 480
  • [50] The single-layer readout electronics design and development for CEPC scintillator analog hadronic calorimeter prototype
    Zhou, Anshun
    Shen, Zhongtao
    Shi, Yukun
    Liu, Shubin
    JOURNAL OF INSTRUMENTATION, 2023, 18 (05)