Advanced template matching method for estimation of intervertebral kinematics of lumbar spine

被引:32
作者
Cerciello, T. [1 ]
Romano, M. [1 ]
Bifulco, P. [1 ]
Cesarelli, M. [1 ]
Allen, R. [2 ]
机构
[1] Univ Naples Federico II, Dept Biomed Elect & Telecommun Engn, I-80125 Naples, Italy
[2] Univ Southampton, Inst Sound & Vibrat Res, Southampton SO17 1BJ, Hants, England
关键词
Intervertebral kinematics; Fluoroscopic sequences; Vertebra tracking; Image template matching; INSTANTANEOUS CENTERS; FINITE CENTER; ROTATION; MOTION; INSTABILITY; VERTEBRAE; RECOGNITION; PLANE; PAIN;
D O I
10.1016/j.medengphy.2011.06.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Diagnosis of low back pain and other degenerative spinal pathologies can be extremely difficult and, so far, there are not accepted standards. In general, such pathologies are associated with alteration of mechanical properties of spine and, in particular, with the instability of spinal motion. Intervertebral kinematics can be a valuable, objective method to assess the functionality of spinal segments. Fluoroscopic imaging system can provide continuous screening of lumbar tracts during patient's motion, with an acceptable low X-ray dose. Estimation of intervertebral kinematics relies on accurate recognition of vertebrae positions throughout the fluoroscopic sequence: specific vertebrae features are identified and tracked either by manual selection or by automated methods. This study presents a new method of vertebra tracking, based on image template matching of the contour of the vertebral body for an accurate intervertebral kinematics analysis. An image gradient operator was utilized to obtain the vertebral contours: it operates after an edge-preserving smoothing filter designed to reduce low dose X-ray image noise. Once a template is defined for each vertebra, this is used to determine the best vertebral location in each image throughout the fluoroscopic sequence. Accuracy of the proposed method was tested using images of a calibration model. Average error achieved for the intervertebral angle is of the order of 0.4 degrees and approximately 2 mm for the intervertebral centre of rotation. Five fluoroscopic lumbar sequences of healthy volunteers undergoing passive flexion extension motion were processed. The intervertebral kinematics was compared with other methods (automated and manual) by an estimation of measurement error. Results showed that the current method provides a better representation of the evolution over time of kinematic parameters. In particular, root mean square differences between the current method and a manual selection procedure performed by an experienced and trained clinician resulted 1.3 degrees for the intervertebral angles and 0.9 mm for the intervertebral trajectory. The proposed method provides an effective, automated and objective technique for estimation of intervertebral kinematics of lumbar spine. (C) 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1293 / 1302
页数:10
相关论文
共 47 条
[1]  
AACH T, 1996, BILDVERARBEITUNG MED, P95
[2]   'Stress' distributions inside intervertebral discs - The effects of age and degeneration [J].
Adams, MA ;
McNally, DS ;
Dolan, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (06) :965-972
[3]   A technique to measure three-dimensional in vivo rotation of fused and adjacent lumbar vertebrae [J].
Anderst, William J. ;
Vaidya, Rahul ;
Tashman, Scott .
SPINE JOURNAL, 2008, 8 (06) :991-997
[4]   Estimation of sub-pixel motion using gradient cross-correlation [J].
Argyriou, V ;
Vlachos, T .
ELECTRONICS LETTERS, 2003, 39 (13) :980-982
[5]   Evaluation of spinal kinematics following lumbar total disc replacement and circumferential fusion using in vivo fluoroscopy [J].
Auerbach, Joshua D. ;
Wills, Brian P. D. ;
McIntosh, Theresa C. ;
Balderston, Richard A. .
SPINE, 2007, 32 (05) :527-536
[6]  
BARRETT HH, 1981, RADIOLOGICAL IMAGING, P29
[7]   Estimation of out-of-plane vertebra rotations on radiographic projections using CT data: a simulation study [J].
Bifulco, P ;
Sansone, M ;
Cesarelli, M ;
Allen, R ;
Bracale, M .
MEDICAL ENGINEERING & PHYSICS, 2002, 24 (04) :295-300
[8]   Automatic recognition of vertebral landmarks in fluoroscopic sequences for analysis of intervertebral kinematics [J].
Bifulco, P ;
Cesarelli, M ;
Allen, R ;
Sansone, M ;
Bracale, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2001, 39 (01) :65-75
[9]  
BIFULCO P, 2010, EURASIP J ADV SIG PR, P1
[10]  
Bogduk N, 1995, Proc Inst Mech Eng H, V209, P177, DOI 10.1243/PIME_PROC_1995_209_341_02