Electrochemical treatment of pharmaceutical wastewater by combining anodic oxidation with ozonation

被引:19
作者
Menapace, Hannes M. [1 ]
Diaz, Nicolas [2 ]
Weiss, Stefan [3 ]
机构
[1] Univ Min & Met Leoben, Inst Sustainable Waste Management & Technol, A-8700 Leoben, Austria
[2] Univ Concepcion, Dept Chem Engn, Concepcion, Chile
[3] Umweltbundesamt GmbH, Vienna, Austria
来源
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING | 2008年 / 43卷 / 08期
关键词
anodic oxidation; ozonation; pharmaceutical wastewater; endocrine substances; complexing agents; EDTA; diamond electrodes;
D O I
10.1080/10934520801974558
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Wastewater effluents from sewage treatment plants (STP) are important point sources for residues of pharmaceuticals and complexing agents in the aquatic environment. For this reason a research project, which started in December 2006, was established to eliminate pharmaceutical substances and complexing agents found in wastewater as micropollutants. For the treatment process a combination of anodic oxidation by boron-doped diamond (BDD) electrodes and ozonation is examined and presented. For the ozone production a non-conventional, separate reactor was used, in which ozone was generated by electrolysis with diamond electrodes For the determination of the achievable remediation rates four complexing agents (e.g., EDTA, NTA) and eight pharmaceutical substances (e.g., diazepam, carbamazepin) were analyzed in several test runs under different conditions (varied flux, varied current density for the diamond electrode and the ozone producing electrode of the ozone generator, different packing materials for the column in the ozone injection system). The flowrates of the treated water samples were varied from 3 L/h up to 26 L/h. For the anodic oxidation the influence of the current density was examined in the range between 22.7 and 45.5 mA/cm(2), for the ozone producing reactor two densities (1.8 a/cm(2) and 2.0 A/cm(2)) were tested. Matrix effects were investigated by test runs with samples from the effluent of an STP and synthetic waste water. Therefore the impact of the organic material in the samples could be determined by the comparison of the redox potential and the achievable elimination rates of the investigated substances. Comparing both technologies anodic oxidation seems to be superior to ozonation in each investigated area. With the used technology of anodic oxidation elimination rates up to 99% were reached for the investigated pharmaceutical substances at a current density of 45.5 mA/cm(2) and a maximum sample flux of 26 L/h.
引用
收藏
页码:961 / 968
页数:8
相关论文
共 17 条
[1]  
ANGUS JC, 2004, THIN FILM DIAMOND, V2, P545
[2]   Treatment of pharmaceutical wastewater containing antibiotics by O3 and O3/H2O2 processes [J].
Balcioglu, IA ;
Ötker, M .
CHEMOSPHERE, 2003, 50 (01) :85-95
[3]   Electro-combustion of polyacrylates with boron-doped diamond anodes [J].
Bellagamba, R ;
Michaud, PA ;
Comninellis, C ;
Vatistas, N .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (02) :171-176
[4]  
*BGBI, 2005, 96 BGBI
[5]  
CHUZ AK, 2005, ARBEITSKREIS CHEM UB
[6]  
*DIN, 2004, 384063 DIN 3
[7]  
GANS O, 2002, BE202 AUSTR FED ENV
[8]   Occurrence of antibiotics in the aquatic environment [J].
Hirsch, R ;
Ternes, T ;
Haberer, K ;
Kratz, KL .
SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 225 (1-2) :109-118
[9]   Monitoring of selected estrogenic hormones and industrial chemicals in groundwaters and surface waters in Austria [J].
Hohenblum, P ;
Gans, O ;
Moche, W ;
Scharf, S ;
Lorbeer, G .
SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 333 (1-3) :185-193
[10]   Degradation of mixtures of phenols using boron doped diamond electrodes for wastewater treatment [J].
Morao, A ;
Lopes, A ;
de Amorim, MTP ;
Gonçalves, IC .
ELECTROCHIMICA ACTA, 2004, 49 (9-10) :1587-1595