Geometric calibration of a mobile C-arm for intraoperative cone-beam CT

被引:70
作者
Daly, M. J. [1 ]
Siewerdsen, J. H. [1 ,2 ]
Cho, Y. B. [3 ]
Jaffray, D. A. [1 ,3 ,4 ,5 ]
Irish, J. C. [2 ,6 ]
机构
[1] Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Otolaryngol Head & Neck Surg, Toronto, ON M5G 2M9, Canada
[3] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[4] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
[5] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5G 2M9, Canada
[6] Unit Hlth Network, Dept Surg Oncol, Toronto, ON M5G 2M9, Canada
关键词
geometric calibration; cone-beam CT; C-arm; flat-panel detector; image-guided interventions; intraoperative imaging; imaging performance;
D O I
10.1118/1.2907563
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A geometric calibration method that determines a complete description of source-detector geometry was adapted to a mobile C-arm for cone-beam computed tomography (CBCT). The non-iterative calibration algorithm calculates a unique solution for the positions of the source (X-s,Y-s,Z(s)), detector (X-d,Y-d,Z(d)), piercing point (U-o,V-o), and detector rotation angles (phi,theta,eta) based on projections of a phantom consisting of two plane-parallel circles of ball bearings encased in a cylindrical acrylic tube. The prototype C-arm system was based on a Siemens PowerMobil modified to provide flat-panel CBCT for image-guided interventions. The magnitude of geometric nonidealities in the source-detector orbit was measured, and the short-term (similar to 4 h) and long-term (similar to 6 months) reproducibility of the calibration was evaluated. The C-arm exhibits large geometric nonidealities due to mechanical flex, with maximum departures from the average semicircular orbit of Delta U-o=15.8 mm and Delta V-o=9.8 mm (for the piercing point), Delta X and Delta Y=6-8 mm and Delta Z=1 mm (for the source and detector), and Delta phi similar to 2.9 degrees, Delta theta similar to 1.9 degrees, and Delta eta similar to 0.8 degrees (for the detector tilt/rotation). Despite such significant departures from a semicircular orbit, these system parameters were found to be reproducible, and therefore correctable by geometric calibration. Short-term reproducibility was < 0.16 mm (subpixel) for the piercing point coordinates, < 0.25 mm for the source-detector X and Y, < 0.035 mm for the source-detector Z, and < 0.02 degrees for the detector angles. Long-term reproducibility was similarly high, demonstrated by image quality and spatial resolution measurements over a period of 6 months. For example, the full-width at half-maximum (FWHM) in axial images of a thin steel wire increased slightly as a function of the time (Delta) between calibration and image acquisition: FWHM=0.62, 0.63, 0.66, 0.71, and 0.72 mm at Delta=0 s, 1 h, 1 day, 1 month, and 6 months, respectively. For ongoing clinical trials in CBCT-guided surgery at our institution, geometric calibration is conducted monthly to provide sufficient three-dimensional (3D) image quality while managing time and workflow considerations of the calibration and quality assurance process. The sensitivity of 3D image quality to each of the system parameters was investigated, as was the tolerance to systematic and random errors in the geometric parameters, showing the most sensitive parameters to be the piercing point coordinates (U-o,V-o) and in-plane positions of the source (X-s,Y-s) and detector (X-d,Y-d). Errors in the out-of-plane position of the source (Z(s)) and detector (Z(d)) and the detector angles (phi,theta,eta) were shown to have subtler effects on 3D image quality. (c) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:2124 / 2136
页数:13
相关论文
共 33 条
  • [1] CHAN Y, 2006, IN PRESS J OTOLARYNG
  • [2] An innovative phantom for quantitative and qualitative investigation of advanced x-ray imaging technologies
    Chiarot, CB
    Siewerdsen, JH
    Haycocks, T
    Moseley, DJ
    Jaffray, DA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (21) : N287 - N297
  • [3] Accurate technique for complete geometric calibration of cone-beam computed tomography systems
    Cho, YB
    Moseley, DJ
    Siewerdsen, JH
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 2005, 32 (04) : 968 - 983
  • [4] Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype
    Daly, M. J.
    Siewerdsen, J. H.
    Moseley, D. J.
    Jaffray, D. A.
    Irish, J. C.
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3767 - 3780
  • [5] Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities
    Fahrig, R
    Holdsworth, DW
    [J]. MEDICAL PHYSICS, 2000, 27 (01) : 30 - 38
  • [6] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [7] Flat-panel cone-beam computed tomography for image-guided radiation therapy
    Jaffray, DA
    Siewerdsen, JH
    Wong, JW
    Martinez, AA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05): : 1337 - 1349
  • [8] Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    Jaffray, DA
    Siewerdsen, JH
    [J]. MEDICAL PHYSICS, 2000, 27 (06) : 1311 - 1323
  • [9] JAFFRAY DA, 2005, P SOC PHOTO-OPT INS, V4682, P241
  • [10] Intraoperative cone-beam CT for image-guided tibial plateau fracture reduction
    Khoury, A.
    Siewerdsen, J. H.
    Whyne, C. M.
    Daly, M. J.
    Kreder, H. J.
    Moseley, D. J.
    Jaffray, D. A.
    [J]. COMPUTER AIDED SURGERY, 2007, 12 (04) : 195 - 207