Development of a gas chromatography inductively coupled plasma isotope dilution mass spectrometry system for accurate determination of volatile element species .1. Selenium speciation

被引:69
作者
Gallus, SM [1 ]
Heumann, KG [1 ]
机构
[1] UNIV MAINZ,INST INORGAN & ANALYT CHEM,D-55099 MAINZ,GERMANY
关键词
inductively coupled plasma mass spectrometry; gas chromatographic coupling; isotope dilution; volatile element species; selenium speciation;
D O I
10.1039/ja9961100887
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of element species in the environment is often especially difficult due to their presence at low concentrations, The coupling of GC with ICP-MS offers the advantage of transferring the total analyte into the ICP-MS instrument without any loss of analyte by nebulization. The application of IDMS results in relatively accurate results. The described GC-ICP-IDMS system consists of a gas chromatograph fitted with a capillary column, for analytical separation, and a diffusion cell that is used to exactly determine the mass discrimination factor for the isotope ratio measurement and to perform an element specific optimization of the plasma conditions. The construction of a relatively simple and low cost transfer line as well as the interface between GC and ICP-MS is described in detail. The applicability of the developed GC-ICP-IDMS system for the determination of volatile element species is demonstrated by the determination of selenite. Selenite is converted into a volatile piazselenol prior to determination, Selenate is determined after conversion into selenite, By applying 62% enriched Se-82 selenite spike solution for the isotope dilution step, the Se-77:Se-82 and Se-78: Se-82 ratios, respectively, could be used for content calculation. Selenite (10 ng ml(-1)) was determined in a water sample with good agreement (within 1%) between the results obtained using the two isotope ratios, The accuracy of the results was demonstrated by the analysis of standard reference materials, The detection limit of the described method was found to be 0.02 ng ml(-1).
引用
收藏
页码:887 / 892
页数:6
相关论文
共 35 条
[1]   1,2-DIAMINOBENZENE DERIVATIVES FOR THE DETERMINATION OF SELENIUM BY GAS-CHROMATOGRAPHY [J].
ALATTAR, AF ;
NICKLESS, G .
JOURNAL OF CHROMATOGRAPHY, 1988, 440 :333-352
[2]  
[Anonymous], 1988, INORGANIC MASS SPECT
[3]   DEVELOPMENT OF A COUPLED LIQUID-CHROMATOGRAPHY ISOTOPE-DILUTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY METHOD FOR LEAD SPECIATION [J].
BROWN, AA ;
EBDON, L ;
HILL, SJ .
ANALYTICA CHIMICA ACTA, 1994, 286 (03) :391-399
[4]   OPTIMAL CONDITIONS FOR THE REDUCTION OF SELENATE TO SELENITE BY HYDROCHLORIC-ACID [J].
BYE, R ;
LUND, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 332 (03) :242-244
[5]  
Catterick T, 1995, ATOM SPECTROSC, V16, P229
[6]  
Craig, 1986, ORGANOMETALLIC COMPO
[7]   APPLICATION OF HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY TO THE INVESTIGATION OF CADMIUM SPECIATION IN PIG-KIDNEY FOLLOWING COOKING AND INVITRO GASTROINTESTINAL DIGESTION [J].
CREWS, HM ;
DEAN, JR ;
EBDON, L ;
MASSEY, RC .
ANALYST, 1989, 114 (08) :895-899
[8]   ISOTOPE-DILUTION MASS-SPECTROMETRY - WHAT CAN IT CONTRIBUTE TO ACCURACY IN TRACE ANALYSIS [J].
DEBIEVRE, P .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 337 (07) :766-771
[9]   ANALYSIS OF SELENIUM AT THE ULTRA-TRACE LEVEL BY GAS-CHROMATOGRAPHY [J].
DILLI, S ;
SUTIKNO, I .
JOURNAL OF CHROMATOGRAPHY, 1984, 300 (02) :265-302
[10]   DETERMINATION OF SELENIUM BY GAS-CHROMATOGRAPHY ELECTRON-CAPTURE DETECTION USING A RAPID DERIVATIZATION PROCEDURE [J].
ELASEER, A ;
NICKLESS, G .
JOURNAL OF CHROMATOGRAPHY A, 1994, 664 (01) :77-87