An Electrochemical and Raman Scattering Dual Detection Biosensor for Rapid Screening and Biomolecular Profiling of Cancer Biomarkers

被引:6
作者
Dey, Shuvashis [1 ]
Ahmed, Emtiaz [1 ]
Somvanshi, Pranjal Satishchandra [1 ]
Ibn Sina, Abu Ali [1 ]
Wuethrich, Alain [1 ]
Trau, Matt [1 ,2 ]
机构
[1] Univ Queensland, Ctr Personalized Nanomed, Australian Inst Bioengn & Nanotechnol AIBN, Brisbane, Qld 4072, Australia
[2] Univ Queensland, Sch Chem & Mol Biosci, Brisbane, Qld 4072, Australia
基金
澳大利亚研究理事会; 英国医学研究理事会;
关键词
Surface-enhanced Raman scattering; cancer biomarkers; differential pulse voltammetry; dual detection mode; liquid biopsy; LIQUID BIOPSY; IMMUNOSENSOR; IMMUNOASSAY; FUTURE; PD-L1; EGFR; TECHNOLOGIES; SPECTROSCOPY; PLATFORM; LUNG;
D O I
10.3390/chemosensors10030093
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Detecting circulating biomarkers sensitively and quantitatively is paramount for cancer screening, diagnosis, and treatment selection. Particularly, screening of a panel of circulating protein biomarkers followed by mapping of individual biomarkers could assist better diagnosis and understanding of the cancer progression mechanisms. Herein, we present a miniaturized biosensing platform with dual readout schemes (electrochemical and Surface enhanced Raman scattering (SERS)) for rapid cancer screening and specific biomarker expressional profiling to support cancer management. Our approach utilizes a controlled nanomixing phenomena under alternative current electrohydrodynamic condition to improve the isolation of cancer-associated circulating proteins (i.e., Epidermal growth factor receptor (EGFR), BRAF, Programmed death-ligand 1 (PD-L1)) with antibody functionalized sensor surface for rapid and efficient isolation of the targets and subsequent labelling with SERS nanotags. The method employs Differential Pulse Voltammetry (DPV) for rapidly screening for the presence of the circulating proteins on biosensor surface irrespective of their type. Upon positive DPV detection, SERS is applied for sensitive read-out of individual biomarkers biomarker levels. In a proof-of-concept study, we demonstrate the dual detection biosensor for analysing circulating BRAF, EGFR and PDE-1 proteins and successfully screened both ensemble and individual biomarker expressional levels as low as 10 pg (1 ng/mL). Our findings clearly indicate the potential of the proposed method for cancer biomarker analysis which may drive the translation of this dual sensing concept in clinical settings.
引用
收藏
页数:12
相关论文
共 44 条
  • [1] Perspective: The future of liquid biopsy
    Alix-Panabieres, Catherine
    [J]. NATURE, 2020, 579 (7800) : S9 - S9
  • [2] Antal-Szalmas Peter, 2013, EJIFCC, V23, P135
  • [3] Baron AT, 2009, IDRUGS, V12, P302
  • [4] Monitoring Treatment Response and Metastatic Relapse in Advanced Bladder Cancer by Liquid Biopsy Analysis
    Birkenkamp-Demtroder, Karin
    Christensen, Emil
    Nordentoft, Iver
    Knudsen, Michael
    Taber, Ann
    Hoyer, Soren
    Lamy, Philippe
    Agerbaek, Mads
    Jensen, Jorgen Bjerggaard
    Dyrskjot, Lars
    [J]. EUROPEAN UROLOGY, 2018, 73 (04) : 535 - 540
  • [5] Integrated bio-affinity nano-platform into a microfluidic immunosensor based on monoclonal bispecific trifunctional antibodies for the electrochemical determination of epithelial cancer biomarker
    Bravo, Karina
    Ortega, Francisco G.
    Messina, German A.
    Sanz, Maria I.
    Fernandez-Baldo, Martin A.
    Raba, Julio
    [J]. CLINICA CHIMICA ACTA, 2017, 464 : 64 - 71
  • [6] Development of a sandwich ELISA for evaluating soluble PD-L1 (CD274) in human sera of different ages as well as supernatants of PD-L1+ cell lines
    Chen, Yongjing
    Wang, Qin
    Shi, Bimin
    Xu, Ping
    Hu, Zhenhua
    Bai, Lixiong
    Zhang, Xueguang
    [J]. CYTOKINE, 2011, 56 (02) : 231 - 238
  • [7] Ultrasensitive Electrochemical DNA Biosensor Fabrication by Coupling an Integral Multifunctional Zirconia-Reduced Graphene Oxide-Thionine Nanocomposite and Exonuclease I-Assisted Cleavage
    Chen, Zhiqiang
    Liu, Xueqian
    Liu, Dengren
    Li, Fang
    Wang, Li
    Liu, Shufeng
    [J]. FRONTIERS IN CHEMISTRY, 2020, 8
  • [8] Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers
    Chikkaveeraiah, Bhaskara V.
    Bhirde, Ashwinkumar A.
    Morgan, Nicole Y.
    Eden, Henry S.
    Chen, Xiaoyuan
    [J]. ACS NANO, 2012, 6 (08) : 6546 - 6561
  • [9] Colorimetric detection of cancer biomarker based on pH induced color change
    Chu, Binyang
    Qi, Tingting
    Liao, Jinfeng
    Peng, Jingrong
    Li, Wenting
    Fu, Shaozhi
    Luo, Feng
    Qian, Zhiyong
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 166 : 56 - 60
  • [10] Surface-Enhanced Raman Spectroscopy for Cancer Immunotherapy Applications: Opportunities, Challenges, and Current Progress in Nanomaterial Strategies
    Dey, Shuvashis
    Trau, Matt
    Koo, Kevin M.
    [J]. NANOMATERIALS, 2020, 10 (06) : 1 - 15