Radiation dose exposure in multislice computed tomography of the coronaries in comparison with conventional coronary angiography

被引:25
作者
Dill, Thorsten [1 ]
Deetjen, Anja [1 ]
Ekinci, Okan [1 ]
Moellmann, Susanne [1 ]
Conradi, Guido [1 ]
Kluge, Alexander [2 ]
Weber, Christoph [3 ]
Weber, Michael [1 ]
Nef, Holger [1 ]
Hamm, Christian W. [1 ]
机构
[1] Kerckhoff Heart Ctr, Dept Cardiol, D-61231 Bad Nauheim, Germany
[2] Kerckhoff Heart Ctr, Dept Radiol, D-61231 Bad Nauheim, Germany
[3] Univ Hamburg Hosp, Dept Diagnost & Intervent Radiol, D-2000 Hamburg, Germany
关键词
cardiac imaging; computed tomography; coronary angiography; radiation dose;
D O I
10.1016/j.ijcard.2007.02.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Radiation dose exposure is increased in multislice spiral computed tomography (MSCT) compared to conventional coronary angiography (CXA). Methods: Retrospective data analysis of 56 patients (66 8 years, 49 males, body surface area 1.98 +/- 0.18 m(2), heart rate 64 +/- 11 bpm) who underwent MSCT and CXA was performed (MSCT: 16-slice scanner, rotation time 0.375 s, 120 kV, ECG-pulsing; CXA: current technique system build in 2003). Ten patients with bypass grafts underwent bypass angiography in CXA and MSCT. To compare the radiation doses of both investigations, the effective dose (ED) was chosen as the analysis variable. Results: The mean ED for MSCT was 9.76 +/- 1.84 mSv (n=46) for patients without bypass grafts; with calcium scoring the mean ED was 12.46 +/- 2.23 mSv (n = 46). In comparison, the mean ED of CXA was 2.60 +/- 1.27 mSv (n = 46) for patients without bypass grafts; with bypass grafts (n = 10) the mean ED for MSCT was 12.95 +/- 1.75 mSv, for CXA of 6.27 +/- 4.04 mSv, respectively. In MSCT heart rates of <= 60 bpm resulted in lower mean ED than heart rates of > 60 bpm (8.86 +/- 1.24 mSv versus 10.53 +/- 1.86 mSv). Conclusions: MSCT is still associated with a higher radiation dose exposure than CXA. The radiation dose relation is more favorable for MSCT than for CXA in patients with bypass grafts in comparison to patients without bypass grafts. This study emphasizes the importance of dose reduction techniques. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:307 / 311
页数:5
相关论文
共 34 条
[1]  
Achenbach S, 2003, Z KARDIOL, V92, P899, DOI 10.1007/s00392-003-0993-5
[2]  
BURGSTAHLER C, 2005, CARDIOVASC, V5, P26
[3]   Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography [J].
Coles, DR ;
Smail, MA ;
Negus, IS ;
Wilde, P ;
Oberhoff, M ;
Karsch, KR ;
Baumbach, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (09) :1840-1845
[4]  
Delichas MG, 2003, RADIAT PROT DOSIM, V103, P149, DOI 10.1093/oxfordjournals.rpd.a006126
[5]   Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart [J].
Flohr, T ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :907-923
[6]   Advances in cardiac imaging with 16-section CT systems [J].
Flohr, TG ;
Schoepf, UJ ;
Kuettner, A ;
Halliburton, S ;
Bruder, H ;
Suess, C ;
Schmidt, B ;
Hofmann, L ;
Yucel, EK ;
Schaller, S ;
Ohnesorge, BM .
ACADEMIC RADIOLOGY, 2003, 10 (04) :386-401
[7]   Automatic exposure control to reduce the dose in subsecond multislice spiral CT: Phantom measurements and clinical results [J].
Greess, H ;
Wolf, H ;
Suess, C ;
Kalender, WA ;
Bautz, W ;
Baum, U .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (06) :862-869
[8]  
Hacker M, 2005, NUKLEARMED-NUCL MED, V44, P119
[9]   Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates [J].
Hausleiter, J ;
Meyer, T ;
Hadamitzky, M ;
Huber, E ;
Zankl, M ;
Martinoff, S ;
Kastrati, A ;
Schömig, A .
CIRCULATION, 2006, 113 (10) :1305-1310
[10]   Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT [J].
Hunold, P ;
Vogt, FM ;
Schmermund, A ;
Debatin, JF ;
Kerkhoff, G ;
Budde, T ;
Erbel, R ;
Ewen, K ;
Barkhausen, J .
RADIOLOGY, 2003, 226 (01) :145-152