Laryngeal nerve monitoring during thyroid surgery in pregnancy

被引:3
作者
Shankar, KB
Posner, M
Moore, FD
O'Rourke, N
机构
[1] Harvard Univ, Dept Anesthesiol Perioperat & Pain Med, Brigham & Womens Hosp, Sch Med, Boston, MA 02115 USA
[2] Harvard Univ, Dept Surg, Brigham & Womens Hosp, Sch Med, Boston, MA 02115 USA
关键词
laryngeal nerve monitoring; pregnancy; thyroid surgery;
D O I
10.1016/j.jclinane.2004.07.010
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A 32-week partutient required partial thyroidectomy for suspicious carcinoma. The surgeon requested laryngeal nerve monitoring to decrease the chances of laryngeal nerve injury during surgery. After rapid-sequence induction of general anesthesia and intubation, a size 3 laryngeal mask airway was inserted posterior to the endotracheal tube and the cuff inflated with 15 mL of air. A fiberoptic bronchoscope inserted through the laryngeal mask airway provided an unhindered view of vocal cords for laryngeal nerve identification and testing during surgery. This combined technique also offered the advantages of a secured airway, as well as positive pressure ventilation in the parturient during thyroid surgery. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:369 / 371
页数:3
相关论文
共 16 条
[1]   LARYNGEAL MASK AIRWAY AND VISUALIZATION OF VOCAL CORDS DURING THYROID-SURGERY [J].
AKHTAR, TM .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1991, 38 (01) :140-140
[2]   Pregnancy-related mortality in the United States, 1987-1990 [J].
Berg, CJ ;
Atrash, HK ;
Koonin, LM ;
Tucker, M .
OBSTETRICS AND GYNECOLOGY, 1996, 88 (02) :161-167
[3]  
EILSE DW, 1993, COMPLICATIONS HEAD N, P423
[4]   The use of readily available equipment in a simple method for intraoperative monitoring of recurrent laryngeal nerve function during thyroid surgery - Initial experience with more than 300 cases [J].
Eltzschig, HK ;
Posner, M ;
Moore, FD .
ARCHIVES OF SURGERY, 2002, 137 (04) :452-456
[5]   Difficult airway in obstetric anesthesia: A review [J].
Ezri, T ;
Szmuk, P ;
Evron, S ;
Geva, D ;
Hagay, Z ;
Katz, J .
OBSTETRICAL & GYNECOLOGICAL SURVEY, 2001, 56 (10) :631-641
[6]  
GREATOREX RA, 1991, ANN ROY COLL SURG, V73, P352
[7]   Anesthesia-related deaths during obstetric delivery in the United States, 1979-1990 [J].
Hawkins, JL ;
Koonin, LM ;
Palmer, SK ;
Gibbs, CP .
ANESTHESIOLOGY, 1997, 86 (02) :277-284
[8]   Failed intubation revisited: 17-yr experience in a teaching maternity unit [J].
Hawthorne, L ;
Wilson, R ;
Lyons, G ;
Dresner, M .
BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 (05) :680-684
[9]  
Hillermann CL, 2003, CAN J ANAESTH, V50, P189, DOI 10.1007/BF03017855
[10]   The laryngeal mask airway for thyroid and parathyroid surgery [J].
Hobbiger, HE ;
Allen, JG ;
Greatorex, RG ;
Denny, NM .
ANAESTHESIA, 1996, 51 (10) :972-974