Fast Phase-Contrast Cine MRI for Assessing Intracranial Hemodynamics and Cerebrospinal Fluid Dynamics

被引:14
|
作者
Ohno, Naoki [1 ]
Miyati, Tosiaki [1 ]
Noda, Tomohiro [2 ]
Alperin, Noam [3 ]
Hamaguchi, Takashi [4 ]
Ohno, Masako [4 ]
Matsushita, Tatsuhiko [5 ]
Mase, Mitsuhito [6 ]
Gabata, Toshifumi [7 ]
Kobayashi, Satoshi [1 ,7 ]
机构
[1] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[2] Kobe Univ, Dept Radiol, Chuo Ku, 7-5-2 Kusunoki Cho, Kobe, Hyogo 6500017, Japan
[3] Univ Miami, Dept Radiol, 1150 NW 14th St,Suite 713, Miami, FL 33136 USA
[4] Kanazawa Univ Hosp, Dept Radiol Technol, 13-1 Takara Machi, Kanazawa, Ishikawa 9208641, Japan
[5] Kyoto Univ Hosp, Div Clin Radiol Serv, Sakyo Ku, 54 Kawaharacho, Kyoto 6068507, Japan
[6] Nagoya City Univ, Grad Sch Med Sci, Dept Neurosurg, Mizuho Ku, 1-Kawasumi,Mizuho Cho, Nagoya, Aichi 4678601, Japan
[7] Kanazawa Univ Hosp, Dept Radiol, 13-1 Takara Machi, Kanazawa, Ishikawa 9208641, Japan
关键词
phase-contrast; intracranial hemodynamics; cerebrospinal fluid hydrodynamics; respiration; MAGNETIC-RESONANCE; BLOOD-FLOW; PRESSURE; RESPIRATION; RESISTANCE;
D O I
10.3390/diagnostics10040241
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We propose fast phase-contrast cine magnetic resonance imaging (PC-cine MRI) to allow breath-hold acquisition, and we compared intracranial hemo- and hydrodynamic parameters obtained during breath holding between full inspiration and end expiration. On a 3.0 T MRI, using electrocardiogram (ECG)-synchronized fast PC-cine MRI with parallel imaging, rectangular field of view, and segmented k-space, we obtained velocity-mapped phase images at the mid-C2 level with different velocity encoding for transcranial blood flow and cerebrospinal-fluid (CSF) flow. Next, we calculated the peak-to-peak amplitudes of cerebral blood flow (Delta CBF), cerebral venous outflow, intracranial volume change, CSF pressure gradient (Delta PG), and intracranial compliance index. These parameters were compared between the proposed and conventional methods. Moreover, we compared these parameters between different utilized breath-hold maneuvers (inspiration, expiration, and free breathing). All parameters derived from the fast PC method agreed with those from the conventional method. The Delta PG was significantly higher during full inspiration breath holding than at the end of expiration and during free breathing. The proposed fast PC-cine MRI reduced scan time (within 30 s) with good agreement with conventional methods. The use of this method also makes it possible to assess the effects of respiration on intracranial hemo- and hydrodynamics.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Cerebrospinal fluid pulse wave velocity measurements: In vitro and in vivo evaluation of a novel multiband cine phase-contrast MRI sequence
    Sonnabend, Kristina
    Brinker, Gerrit
    Maintz, David
    Bunck, Alexander C.
    Weiss, Kilian
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (01) : 211 - 222
  • [2] Blood and cerebrospinal fluid flow oscillations measured with real-time phase-contrast MRI: breathing mode matters
    Lagana, Maria Marcella
    Di Tella, Sonia
    Ferrari, Francesca
    Pelizzari, Laura
    Cazzoli, Marta
    Alperin, Noam
    Jin, Ning
    Zaca, Domenico
    Baselli, Giuseppe
    Baglio, Francesca
    FLUIDS AND BARRIERS OF THE CNS, 2022, 19 (01)
  • [3] CEREBROSPINAL-FLUID FLOW MEASURED BY PHASE-CONTRAST CINE MR
    ENZMANN, DR
    PELC, NJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1993, 14 (06) : 1301 - 1307
  • [4] Blood and cerebrospinal fluid flow oscillations measured with real-time phase-contrast MRI: breathing mode matters
    Maria Marcella Laganà
    Sonia Di Tella
    Francesca Ferrari
    Laura Pelizzari
    Marta Cazzoli
    Noam Alperin
    Ning Jin
    Domenico Zacà
    Giuseppe Baselli
    Francesca Baglio
    Fluids and Barriers of the CNS, 19
  • [5] Validating the accuracy of real-time phase-contrast MRI and quantifying the effects of free breathing on cerebrospinal fluid dynamics
    Liu, Pan
    Owashi, Kimi
    Monnier, Heimiri
    Metanbou, Serge
    Capel, Cyrille
    Baledent, Olivier
    FLUIDS AND BARRIERS OF THE CNS, 2024, 21 (01)
  • [6] Quantifying the influence of respiration and cardiac pulsations on cerebrospinal fluid dynamics using real-time phase-contrast MRI
    Yildiz, Selda
    Thyagaraj, Suraj
    Jin, Ning
    Zhong, Xiaodong
    Pahlavian, Soroush Heidari
    Martin, Bryn A.
    Loth, Francis
    Oshinski, John
    Sabra, Karim G.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (02) : 431 - 439
  • [7] 3D Cine Phase-Contrast MRI at 3T in Intracranial Aneurysms Compared with Patient-Specific Computational Fluid Dynamics
    van Ooij, P.
    Schneiders, J. J.
    Marquering, H. A.
    Majoie, C. B.
    van Bavel, E.
    Nederveen, A. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (09) : 1785 - 1791
  • [8] Quantitative assessment of physiological cerebrospinal fluid flow in the cervical spinal canal with 3.0T phase-contrast cine MRI
    Shang, Hua
    Liu, Huaijun
    Yan, Leka
    Lei, Jianming
    Cui, Caixia
    Li, Hui
    NEURAL REGENERATION RESEARCH, 2012, 7 (18) : 1392 - 1397
  • [10] ICP Monitoring and Phase-Contrast MRI to Investigate Intracranial Compliance
    Lokossou, A.
    Baledent, O.
    Garnotel, S.
    Page, G.
    Balardy, L.
    Czosnyka, Z.
    Payoux, P.
    Schmidt, E. A.
    INTRACRANIAL PRESSURE & NEUROMONITORING XVI, 2018, 126 : 247 - 253