In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies

被引:1
作者
Ozal, Cise [1 ]
Ulusoy, Mutahhar [1 ]
机构
[1] Near East Univ, Fac Dent, Dept Prosthodont, Near East Blvd,Mersin 10, TR-99138 Nicosia, Turkey
关键词
Dental marginal adaptation; Dental internal adaptation; Computer-aided design; Zirconia; Dental impression techniques; FIXED DENTAL PROSTHESES; CONVENTIONAL IMPRESSIONS; CERAMIC CROWNS; CEMENT SPACE; ACCURACY; ADAPTATION; COPINGS; SCANNERS; SYSTEM;
D O I
10.4047/jap.2021.13.6.373
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This study aimed to compare the marginal and internal fit of 3-unit monolithic zirconia restorations that were designed by using the data obtained with the aid of intraoral and laboratory scanners. MATERIALS AND METHODS. For the fabrication of 3-unit monolithic zirconia restorations using impressions taken from the maxillary master cast, plaster cast was created and scanned in laboratory scanners (InEos X5 and D900L). The main cast was also scanned with different intraoral scanners (Omnicam [OMNI], Primescan [PS], Trios 3 [T3], Trios 4 [T4]) (n = 12 per group). Zirconia fixed partial dentures were virtually designed, produced from presintered block, and subsequently sintered. Marginal and internal discrepancy values (in p.m) were measured by using silicone replica method under stereomicroscope. Data were statistically analyzed by using 1-way ANOVA and Kruskal Wallis tests (P<.05). RESULTS. In terms of marginal adaptation, the measurements on the canine tooth indicated better performance with intraoral scanners than those in laboratory scanners, but there was no difference among intraoral scanners (P<.05). In the premolar tooth, PS had the lowest marginal (86.9 +/- 19.2 p.m) and axial (92.4 +/- 14.8 p.m), and T4 had the lowest axio-occlusal (89.4 +/- 15.6 p.m) and occlusal (89.1 +/- 13.9 p.m) discrepancy value. In both canine and premolar teeth, the D900L was found to be the most marginally and internally inconsistent scanner. CONCLUSION. Within the limits of the study, marginal and internal discrepancy values were generally lower in intraoral scanners than in laboratory scanners. Marginal discrepancy values of scanners were clinically acceptable (< 120 p.m), except D900L. [J Adv Prosthodont 2021;13:373-84]
引用
收藏
页码:373 / 384
页数:12
相关论文
共 50 条
[1]   Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners [J].
Abdel-Azim, Tamer ;
Rogers, Kelly ;
Elathamna, Eiad ;
Zandinejad, Amirali ;
Metz, Michael ;
Morton, Dean .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (04) :554-559
[2]   Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review [J].
Ahlholm, Pekka ;
Sipila, Kirsi ;
Vallittu, Pekka ;
Jakonen, Minna ;
Kotiranta, Ulla .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (01) :35-41
[3]   Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques [J].
Almeida e Silva, Junio S. ;
Erdelt, Kurt ;
Edelhoff, Daniel ;
Araujo, Elito ;
Stimmelmayr, Michael ;
Cardoso Vieira, Luiz Clovis ;
Gueth, Jan-Frederik .
CLINICAL ORAL INVESTIGATIONS, 2014, 18 (02) :515-523
[4]   Comparison of marginal and internal fit of 3-unit zirconia frameworks fabricated with CAD-CAM technology using direct and indirect digital scans [J].
Arezoobakhsh, Ali ;
Shayegh, Sayed Shojaedin ;
Ghomi, Ali Jamali ;
Hakimaneh, Seyed Mohammad Reza .
JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01) :105-112
[5]   Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic fixed partial dentures. Part III: Marginal and internal fit [J].
Benic, Goran, I ;
Sailer, Irena ;
Zeltner, Marco ;
Gutermann, Janine N. ;
Ozcan, Mutlu ;
Muhlemann, Sven .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (03) :426-431
[6]   Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns [J].
Berrendero, S. ;
Salido, M. P. ;
Valverde, A. ;
Ferreiroa, A. ;
Pradies, G. .
Clinical Oral Investigations, 2016, 20 (09) :2403-2410
[7]   Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients [J].
Boeddinghaus, Moritz ;
Breloer, Eva Sabina ;
Rehmann, Peter ;
Woestmann, Bernd .
CLINICAL ORAL INVESTIGATIONS, 2015, 19 (08) :2027-2034
[8]   Comparison of an indirect impression scanning system and two direct intraoral scanning systems in vivo [J].
Bosniac, Patricia ;
Rehmann, Peter ;
Woestmann, Bernd .
CLINICAL ORAL INVESTIGATIONS, 2019, 23 (05) :2421-2427
[9]   Influence of Liquid on the Tooth Surface on the Accuracy of Intraoral Scanners: An In Vitro Study [J].
Chen, Yuming ;
Zhai, Zhihao ;
Li, Hefei ;
Yamada, Shuhei ;
Matsuoka, Takashi ;
Ono, Shinji ;
Nakano, Tamaki .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (01) :59-64
[10]  
Contrepois M, 2013, J PROSTHET DENT, V110, P447, DOI 10.1016/j.prosdent.2013.08.003